Airton Pereira da Costa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Airton Pereira da Costa has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
André Vitor Kerber Cavalcanti Lemos
Escola Paulista de Medicina - UNIFESP, São Paulo, SP, Brazil
1 shared publication- Caio Nery
Orthopedic & Traumatology Department, Federal University of São Paulo - Brazil, Foot and Ankle Clinic
1 shared publication - Eduardo Souza Maciel
Escola Paulista de Medicina - UNIFESP, São Paulo, SP, Brazil
1 shared publication - Eiffel Tsuyoshi Dobashi
Universidade Federal de São Paulo, Brazil
1 shared publication - Erika Tonarelli Rodrigues
Universidade Federal de São Paulo, Brazil
1 shared publication - Hassan Ahmad Hauache Neto
Universidade Federal de São Paulo, Brazil
1 shared publication
Latest Publications
- Open Access
- 18 April 2026
- Published by Associacao Brasileira de Medicina e Cirurgia do Tornozelo e Pe (ABTPe) in Journal of the Foot & Ankle
- Vol. 20 (Suppl 1)
Total ankle arthroplasty with TARIC prosthesis in the Unified Health System: The first 12 months of clinical and radiographic outcomes
Introduction: The evidence of total ankle arthroplasty (TAA) in the Unified Health System (SUS) is limited. The objective was to describe early clinical and radiographic outcomes after primary TAA with TARIC (mobile-bearing) prosthesis in a public hospital. Methods: Retrospective case series (single center, single surgeon). Preoperative evaluation and at 3, 6, and 12 months by VAS, AOFAS, MOXFQ, and ROM; weight-bearing radiographs (AP/mortise/profile) with MDTA, STA, and talar tilt (references: MDTA 85°-95°, STA 80°-90°, tilt -2° to +2°). Paired endpoint: 12 months (n = 12); analysis by Wilcoxon. Results: At 12 months, there was a significant improvement in pain and function: VAS 8.33 ± 1.56→3.17 ± 2.66 (Δ 5.17 ± 2.62; p = 0.00049); AOFAS 40.67 ± 14.90→73.17 ± 14.89 (Δ 32.50 ± 14.96; p = 0.00049); total MOXFQ 0.80 ± 0.13→0.47 ± 0.24 (Δ 0.33 ± 0.25; p = 0.00049); ROM 20.25 ± 10.86→30.50 ± 7.54 (Δ 10.25 ± 16.52; p = 0.042). Radiographically, MDTA normalized (out: 16.7%→0%); STA improved (33.3%→16.7%) with two new cases outside the normal range; tilt talar was the most variable parameter (41.7%→50.0%). Implant-related events included indication for revision for polyethylene dislocation with replacement of the talar and poly components, talar subluxation, and severe varus tilt with polyethylene subluxation, and revision for INBONE at six months for severe arthrofibrosis and joint pain (< 12 months). Conclusion: TAA with TARIC in SUS showed early clinical improvement and consistent correction of the tibial axis; variability in talar tilt and revision events reinforce the need for reliable technical training, as well as systematic radiographic and long term follow-up.
- 18 April 2026
- Published by Associacao Brasileira de Medicina e Cirurgia do Tornozelo e Pe (ABTPe) in Journal of the Foot & Ankle
- Vol. 20 (Suppl 1)
Open AccessTotal ankle arthroplasty with TARIC prosthesis in the Unified Health System: The first 12 months of clinical and radiographic outcomes
Introduction: The evidence of total ankle arthroplasty (TAA) in the Unified Health System (SUS) is limited. The objective was to describe early clinical and radiographic outcomes after primary TAA with TARIC (mobile-bearing) prosthesis in a public hospital. Methods: Retrospective case series (single center, single surgeon). Preoperative evaluation and at 3, 6, and 12 months by VAS, AOFAS, MOXFQ, and ROM; weight-bearing radiographs (AP/mortise/profile) with MDTA, STA, and talar tilt (references: MDTA 85°-95°, STA 80°-90°, tilt -2° to +2°). Paired endpoint: 12 months (n = 12); analysis by Wilcoxon. Results: At 12 months, there was a significant improvement in pain and function: VAS 8.33 ± 1.56→3.17 ± 2.66 (Δ 5.17 ± 2.62; p = 0.00049); AOFAS 40.67 ± 14.90→73.17 ± 14.89 (Δ 32.50 ± 14.96; p = 0.00049); total MOXFQ 0.80 ± 0.13→0.47 ± 0.24 (Δ 0.33 ± 0.25; p = 0.00049); ROM 20.25 ± 10.86→30.50 ± 7.54 (Δ 10.25 ± 16.52; p = 0.042). Radiographically, MDTA normalized (out: 16.7%→0%); STA improved (33.3%→16.7%) with two new cases outside the normal range; tilt talar was the most variable parameter (41.7%→50.0%). Implant-related events included indication for revision for polyethylene dislocation with replacement of the talar and poly components, talar subluxation, and severe varus tilt with polyethylene subluxation, and revision for INBONE at six months for severe arthrofibrosis and joint pain (< 12 months). Conclusion: TAA with TARIC in SUS showed early clinical improvement and consistent correction of the tibial axis; variability in talar tilt and revision events reinforce the need for reliable technical training, as well as systematic radiographic and long term follow-up.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 33 (6)
COMPARATIVE ANALYSIS OF TREATMENTS FOR FOREARM FRACTURES IN CHILDREN: A SYSTEMATIC REVIEW AND META-ANALYSIS
To compare the clinical outcomes of children with forearm bone fractures undergoing surgical treatment with intramedullary fixation with TEN rods and Kirschner wires. A systematic review of the literature was carried out, conducting a search for data in the Pubmed/Medline, Science Direct and Scielo databases. The quality of the trials was assessed by the MINORS tool and the meta-analysis of the studies was performed using the R software (version 4.4.0). 16 studies were selected, representing 1,075 patients, with a predominance of males, where the mean age range varied from 8.32 to 14.2 years. Applying the MINORS Scale, the quality of the studies was good (≥ 11). The meta-analysis of the studies revealed a statistically significant increase in the risk of adverse events in the experimental group compared to the control group, with a risk ratio (RR) of 1.35 (95% CI: 1.03 to 1.76). The combined mean difference (raw mean) between the experimental group and the control group was −12.42 minutes (95% CI: −13.75 to −11.10) in the fixed-effect model, indicating a significant reduction in surgical time for the experimental group. In the random-effect model, the mean difference was −21.62 minutes (95% CI: −33.30 to −9.94). Regarding fracture consolidation time, the fixed-effect model indicated a raw mean difference of 0.99 (95% CI: 0.61 to 1.36). Furthermore, heterogeneity was moderate to high, with an I² of 73% (p < 0.01). Intramedullary fixation with TEN nails and Kirschner wires presents a diversity of clinical outcomes and complications. The systematic review highlighted the importance of choosing the appropriate treatment method, considering the patient characteristics and the nature of the fracture. Level of Evidence II; Systematic Review.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 33 (6)
Open AccessCOMPARATIVE ANALYSIS OF TREATMENTS FOR FOREARM FRACTURES IN CHILDREN: A SYSTEMATIC REVIEW AND META-ANALYSIS
To compare the clinical outcomes of children with forearm bone fractures undergoing surgical treatment with intramedullary fixation with TEN rods and Kirschner wires. A systematic review of the literature was carried out, conducting a search for data in the Pubmed/Medline, Science Direct and Scielo databases. The quality of the trials was assessed by the MINORS tool and the meta-analysis of the studies was performed using the R software (version 4.4.0). 16 studies were selected, representing 1,075 patients, with a predominance of males, where the mean age range varied from 8.32 to 14.2 years. Applying the MINORS Scale, the quality of the studies was good (≥ 11). The meta-analysis of the studies revealed a statistically significant increase in the risk of adverse events in the experimental group compared to the control group, with a risk ratio (RR) of 1.35 (95% CI: 1.03 to 1.76). The combined mean difference (raw mean) between the experimental group and the control group was −12.42 minutes (95% CI: −13.75 to −11.10) in the fixed-effect model, indicating a significant reduction in surgical time for the experimental group. In the random-effect model, the mean difference was −21.62 minutes (95% CI: −33.30 to −9.94). Regarding fracture consolidation time, the fixed-effect model indicated a raw mean difference of 0.99 (95% CI: 0.61 to 1.36). Furthermore, heterogeneity was moderate to high, with an I² of 73% (p < 0.01). Intramedullary fixation with TEN nails and Kirschner wires presents a diversity of clinical outcomes and complications. The systematic review highlighted the importance of choosing the appropriate treatment method, considering the patient characteristics and the nature of the fracture. Level of Evidence II; Systematic Review.