Jianxin Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jianxin Lin has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Huaiyuan Wang
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
2 shared publications - Junxi Yu
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
1 shared publication - Pengjie Chen
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
1 shared publication - Xuchang Wang
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou 350108, China
1 shared publication - Yujia Lin
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
1 shared publication
Latest Publications
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Adaptive Critical Cost-Sensitive Detection of High-Impedance Faults Based on Impedance Criticality
High-impedance fault (HIF) in distribution networks is notoriously difficult to detect, as its high impedance results in weak fault currents that evade conventional protection schemes. In addition, for both HIF and non-HIF samples, the impact of critical samples on the detection rules is regarded as more important than that of non-critical samples. Therefore, a critical cost-sensitive factor distribution (CCFD) method based on impedance criticality is proposed in this study. A higher cost factor is assigned to critical samples than to non-critical samples. To better learn from the misclassified samples and reduce the interference of anomalous samples, an adaptive critical cost-sensitivity factor distribution (ACCFD) method is further proposed. During model training, the distribution factors of consecutively misclassified and correctly classified samples within the critical sample set are adaptively adjusted to optimize the detection rules. Experiments are conducted on a 10 kV distribution network simulation model and a field experiment platform. The results demonstrate that the proposed ACCFD method exhibits high classification accuracy and excellent generalization ability, effectively enhancing the reliability and security of power grids.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Adaptive Critical Cost-Sensitive Detection of High-Impedance Faults Based on Impedance Criticality
High-impedance fault (HIF) in distribution networks is notoriously difficult to detect, as its high impedance results in weak fault currents that evade conventional protection schemes. In addition, for both HIF and non-HIF samples, the impact of critical samples on the detection rules is regarded as more important than that of non-critical samples. Therefore, a critical cost-sensitive factor distribution (CCFD) method based on impedance criticality is proposed in this study. A higher cost factor is assigned to critical samples than to non-critical samples. To better learn from the misclassified samples and reduce the interference of anomalous samples, an adaptive critical cost-sensitivity factor distribution (ACCFD) method is further proposed. During model training, the distribution factors of consecutively misclassified and correctly classified samples within the critical sample set are adaptively adjusted to optimize the detection rules. Experiments are conducted on a 10 kV distribution network simulation model and a field experiment platform. The results demonstrate that the proposed ACCFD method exhibits high classification accuracy and excellent generalization ability, effectively enhancing the reliability and security of power grids.
- Open Access
Physics-Informed SDAE-Based Denoising Model for High-Impedance Fault Detection
The accurate detection of high-impedance faults (HIFs) in distribution systems is fundamentally dependent on the extraction of weak fault signatures. However, these features are often obscured by complex and high-level noise present in current transformer (CT) measurement data. To address this challenge, an energy-proportion-guided channel-wise attention stacked denoising autoencoder (EPGCA-SDAE) model is proposed. In this model, wavelet decomposition is employed to transform the signal into informative frequency band components. A channel attention mechanism is utilized to adaptively assign weights to each component, thereby enhancing model interpretability. Furthermore, a physics-informed prior, based on energy distribution, is introduced to guide the loss function and regulate the attention learning process. Extensive simulations using both synthetic and real-world distribution network data are conducted. The superiority of the EPGCA-SDAE over traditional wavelet-based methods, stacked denoising autoencoders (SDAE), denoising convolutional neural network (DnCNN), and Transformer-based networks across various noise conditions is demonstrated. The lowest average mean squared error (MSE) is achieved by the proposed model (simulated: ; real: ), along with enhanced noise robustness, generalization capability, and physical interpretability. These results verify the method’s feasibility within the tested 10 kV distribution system, providing a reliable data recovery framework for fault diagnosis in noise-contaminated distribution network environments.Open AccessPhysics-Informed SDAE-Based Denoising Model for High-Impedance Fault Detection
The accurate detection of high-impedance faults (HIFs) in distribution systems is fundamentally dependent on the extraction of weak fault signatures. However, these features are often obscured by complex and high-level noise present in current transformer (CT) measurement data. To address this challenge, an energy-proportion-guided channel-wise attention stacked denoising autoencoder (EPGCA-SDAE) model is proposed. In this model, wavelet decomposition is employed to transform the signal into informative frequency band components. A channel attention mechanism is utilized to adaptively assign weights to each component, thereby enhancing model interpretability. Furthermore, a physics-informed prior, based on energy distribution, is introduced to guide the loss function and regulate the attention learning process. Extensive simulations using both synthetic and real-world distribution network data are conducted. The superiority of the EPGCA-SDAE over traditional wavelet-based methods, stacked denoising autoencoders (SDAE), denoising convolutional neural network (DnCNN), and Transformer-based networks across various noise conditions is demonstrated. The lowest average mean squared error (MSE) is achieved by the proposed model (simulated: ; real: ), along with enhanced noise robustness, generalization capability, and physical interpretability. These results verify the method’s feasibility within the tested 10 kV distribution system, providing a reliable data recovery framework for fault diagnosis in noise-contaminated distribution network environments.