Minhan Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Minhan Kim has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Byoungsun Park
Technical Research Center, HSKorea Co., Ltd., Doosan VentureDigm #826, 415 Heungan-daero, Dongan-gu, Anyang-si 14059, Gyeonggi-do, Republic of Korea
1 shared publication - ChangKyoo Yoo
Integrated Engineering, Dept. of Environmental Science and Engineering, College of Engineering, Kyung Hee University, 1732 Deogyeong-daero, Giheung-gu, Yongin-Si, Gyeonggi-do 17104, Republic of Korea
1 shared publication - Hongseok Kim
Technical Research Center, HSKorea Co., Ltd., Doosan VentureDigm #826, 415 Heungan-daero, Dongan-gu, Anyang-si 14059, Gyeonggi-do, Republic of Korea
1 shared publication - Junghee Jang
Plant Engineering Center, Institute for Advanced Engineering, 633-2 Goan-ri, Baegam-myon, Cheoin-gu, Yongin-si 17528, Gyeonggi-do, Republic of Korea
1 shared publication - Sangyoun Kim
Integrated Engineering, Department of Environmental Science and Engineering, College of Engineering, Kyung Hee University, 1732 Deogyeong-daero, Giheung-gu, Yongin-si 17104, Gyeonggi-do, Republic of Korea
1 shared publication - Seong-Wook Park
Technical Research Center, HSKorea Co., Ltd., Doosan VentureDigm #826, 415 Heungan-daero, Dongan-gu, Anyang-si 14059, Gyeonggi-do, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Optical Analysis Based on UV Absorption Spectrum for Monitoring Total Organic Carbon and Nitrate Nitrogen in River Water
The global deterioration of water quality due to climate change and industrialization has intensified the need for real-time monitoring systems. In South Korea’s automated water quality monitoring networks, measuring total organic carbon (TOC) and nitrate nitrogen (NO3-N) as a proxy for total nitrogen (TN) is critical; however, conventional analytical instruments face limitations such as high costs, long analysis times, and the need for chemical reagents. In this study, we developed and evaluated a simultaneous TOC and NO3-N measurement method using HASM-4000, a domestically developed optical sensor based on ultraviolet (UV) absorption spectroscopy. The sensor measures absorbance at 254 nm (TOC) and 220 nm (NO3-N) based on the Beer–Lambert law, with signal processing techniques including optical power compensation (OPC) and Binning–Interpolation (BinInterp) applied to enhance measurement accuracy. Calibration using standard solutions demonstrated excellent linear correlations (R2 > 0.99) between actual and estimated concentrations for both TOC and NO3-N, with accuracy and reproducibility validated against standard methods under laboratory conditions. However, performance degradation was observed in turbid mixed samples due to the optical limitations of the 10 mm pathlength, suggesting the need for future improvements such as adopting a 5 mm pathlength and upgrading optical components. The HASM-4000 sensor enables real-time measurement without a reagent, and preliminary testing with river water samples demonstrates its potential to advance Korea’s water quality monitoring infrastructure by reducing dependence on foreign technologies and facilitating network expansion with cost-effective domestic solutions.
Open AccessOptical Analysis Based on UV Absorption Spectrum for Monitoring Total Organic Carbon and Nitrate Nitrogen in River Water
The global deterioration of water quality due to climate change and industrialization has intensified the need for real-time monitoring systems. In South Korea’s automated water quality monitoring networks, measuring total organic carbon (TOC) and nitrate nitrogen (NO3-N) as a proxy for total nitrogen (TN) is critical; however, conventional analytical instruments face limitations such as high costs, long analysis times, and the need for chemical reagents. In this study, we developed and evaluated a simultaneous TOC and NO3-N measurement method using HASM-4000, a domestically developed optical sensor based on ultraviolet (UV) absorption spectroscopy. The sensor measures absorbance at 254 nm (TOC) and 220 nm (NO3-N) based on the Beer–Lambert law, with signal processing techniques including optical power compensation (OPC) and Binning–Interpolation (BinInterp) applied to enhance measurement accuracy. Calibration using standard solutions demonstrated excellent linear correlations (R2 > 0.99) between actual and estimated concentrations for both TOC and NO3-N, with accuracy and reproducibility validated against standard methods under laboratory conditions. However, performance degradation was observed in turbid mixed samples due to the optical limitations of the 10 mm pathlength, suggesting the need for future improvements such as adopting a 5 mm pathlength and upgrading optical components. The HASM-4000 sensor enables real-time measurement without a reagent, and preliminary testing with river water samples demonstrates its potential to advance Korea’s water quality monitoring infrastructure by reducing dependence on foreign technologies and facilitating network expansion with cost-effective domestic solutions.