Oscar Prades-Mateu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oscar Prades-Mateu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Guillem Monrós-Andreu
Department of Mechanic Engineering and Construction, University Jaume I, Av. Vicent Sos Baynat, s/n, 12071 Castelló de la Plana, Castelló, Spain
4 shared publications - Raúl Martínez-Cuenca
Department of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castelló de la Plana, Spain
4 shared publications - Salvador Torró
Department of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castelló de la Plana, Spain
4 shared publications - Sergio Chiva
Department of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castelló de la Plana, Spain
4 shared publications - Jaume Luis-Gómez
Department of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castelló de la Plana, Spain
2 shared publications - Delia Trifi
Department of Mechanical Engineering and Construction, Universitat Jaume I, 12071 Castelló de la Plana, Spain
1 shared publication
Latest Publications
- Open Access
- 4 March 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (9)
CFD analysis of diffuser configurations for enhanced oxygen transfer and flow mixing in two-phase reactor systems
- 4 March 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (9)
Open AccessCFD analysis of diffuser configurations for enhanced oxygen transfer and flow mixing in two-phase reactor systems
- Open Access
Effects of SDS Surfactant on Oxygen Transfer in a Fine-Bubble Diffuser Aeration Column
Aeration is one of the most energy-intensive operations in wastewater treatment plants, with its efficiency strongly affected by the presence of surfactants. This study investigates the impact of Sodium Dodecyl Sulphate (SDS) on oxygen mass transfer using a commercial fine-bubble diffuser. Oxygen transfer experiments were performed under varying air flow rates and SDS concentrations. Key parameters, including the volumetric mass transfer coefficient (), gas holdup, bubble size, and interfacial area, were experimentally measured and analysed. SDS reduces the average bubble diameter by up to 50%; above 4 mg/L, further increases in concentration do not change the bubble size. Gas holdup increases by approximately 2% per mg L−1 of SDS, and a new empirical correlation was proposed to predict gas holdup as a function of air flow rate and surfactant concentration, achieving an R2 of 0.97 with deviations below 10%. Despite the increase in interfacial area, SDS strongly suppresses interfacial turbulence, reducing the liquid-side mass transfer coefficient () by up to 70%, which ultimately leads to a significant loss of overall oxygen transfer efficiency. The Sardeing model, originally developed for single bubbles, successfully predicted within ±15% of the experimental values, demonstrating its potential as a practical tool for estimating oxygen transfer in aeration systems. These findings highlight the substantial impact of surfactants on fine-bubble aeration performance and underscore the need to account for their effects in the design and operation of industrial aeration systems.Open AccessEffects of SDS Surfactant on Oxygen Transfer in a Fine-Bubble Diffuser Aeration Column
Aeration is one of the most energy-intensive operations in wastewater treatment plants, with its efficiency strongly affected by the presence of surfactants. This study investigates the impact of Sodium Dodecyl Sulphate (SDS) on oxygen mass transfer using a commercial fine-bubble diffuser. Oxygen transfer experiments were performed under varying air flow rates and SDS concentrations. Key parameters, including the volumetric mass transfer coefficient (), gas holdup, bubble size, and interfacial area, were experimentally measured and analysed. SDS reduces the average bubble diameter by up to 50%; above 4 mg/L, further increases in concentration do not change the bubble size. Gas holdup increases by approximately 2% per mg L−1 of SDS, and a new empirical correlation was proposed to predict gas holdup as a function of air flow rate and surfactant concentration, achieving an R2 of 0.97 with deviations below 10%. Despite the increase in interfacial area, SDS strongly suppresses interfacial turbulence, reducing the liquid-side mass transfer coefficient () by up to 70%, which ultimately leads to a significant loss of overall oxygen transfer efficiency. The Sardeing model, originally developed for single bubbles, successfully predicted within ±15% of the experimental values, demonstrating its potential as a practical tool for estimating oxygen transfer in aeration systems. These findings highlight the substantial impact of surfactants on fine-bubble aeration performance and underscore the need to account for their effects in the design and operation of industrial aeration systems. - Open Access
Characterization of a Multi-Diffuser Fine-Bubble Aeration Reactor: Influence of Local Parameters and Hydrodynamics on Oxygen Transfer
Fine-bubble aeration is a core process in wastewater treatment plants (WWTPs). However, the physical mechanisms linking bubble plume hydrodynamics to oxygen transfer performance remain insufficiently quantified under configurations representative of full-scale installations. This study presents a local multi-sensor experimental characterization of a multiple bubble plume system using a 4 × 4 array of commercial membrane diffusers in a pilot-scale aeration tank (2 m3), emulating WWTP diffuser density and geometry. Airflow rate was varied to analyze its effects on mixing and oxygen transfer efficiency. The experimental methodology combines three complementary measurement approaches. Oxygen transfer performance is quantified using a dissolved oxygen probe. Liquid-phase velocity fields are then mapped using Acoustic Doppler Velocimetry (ADV). Finally, local two-phase measurements are obtained using dual-tip Conductivity Probe (CP) arrays, which provide bubble size, bubble velocity, void fraction, and Interfacial Area Concentration (IAC). Based on these observations, a zonal hydrodynamic model is proposed to describe plume interaction, wall-driven recirculation, and the formation of a collective plume core at higher airflows. Quantitatively, the results reveal a 29% reduction in Standard Oxygen Transfer Efficiency (SOTE) between 10 and 40 m3/h, driven by a 41% increase in bubble size and an 18% rise in bubble velocity. Bubble chord length also increased with height, by 33%, 19%, and 15% over 0.8 m for 10, 20, and 40 m3/h, respectively. These trends indicate that increasing airflow enhances turbulent mixing but simultaneously enlarges bubbles and accelerates their ascent, thereby reducing residence time and negatively affecting oxygen transfer. Overall, the validated multiphase datasets and mechanistic insights demonstrate the dominant role of diffuser interaction in dense layouts, supporting improved parameterization and experimental benchmarking of fine-bubble aeration systems in WWTPs.
Open AccessCharacterization of a Multi-Diffuser Fine-Bubble Aeration Reactor: Influence of Local Parameters and Hydrodynamics on Oxygen Transfer
Fine-bubble aeration is a core process in wastewater treatment plants (WWTPs). However, the physical mechanisms linking bubble plume hydrodynamics to oxygen transfer performance remain insufficiently quantified under configurations representative of full-scale installations. This study presents a local multi-sensor experimental characterization of a multiple bubble plume system using a 4 × 4 array of commercial membrane diffusers in a pilot-scale aeration tank (2 m3), emulating WWTP diffuser density and geometry. Airflow rate was varied to analyze its effects on mixing and oxygen transfer efficiency. The experimental methodology combines three complementary measurement approaches. Oxygen transfer performance is quantified using a dissolved oxygen probe. Liquid-phase velocity fields are then mapped using Acoustic Doppler Velocimetry (ADV). Finally, local two-phase measurements are obtained using dual-tip Conductivity Probe (CP) arrays, which provide bubble size, bubble velocity, void fraction, and Interfacial Area Concentration (IAC). Based on these observations, a zonal hydrodynamic model is proposed to describe plume interaction, wall-driven recirculation, and the formation of a collective plume core at higher airflows. Quantitatively, the results reveal a 29% reduction in Standard Oxygen Transfer Efficiency (SOTE) between 10 and 40 m3/h, driven by a 41% increase in bubble size and an 18% rise in bubble velocity. Bubble chord length also increased with height, by 33%, 19%, and 15% over 0.8 m for 10, 20, and 40 m3/h, respectively. These trends indicate that increasing airflow enhances turbulent mixing but simultaneously enlarges bubbles and accelerates their ascent, thereby reducing residence time and negatively affecting oxygen transfer. Overall, the validated multiphase datasets and mechanistic insights demonstrate the dominant role of diffuser interaction in dense layouts, supporting improved parameterization and experimental benchmarking of fine-bubble aeration systems in WWTPs.
- Open Access
- 14 November 2025
- Published by MDPI AG in Preprints.org
Surfactant Effects on Oxygen Transfer and Bubble Dynamics in a Fine-Bubble Diffuser Aeration Column
Aeration is one of the most energy-intensive operations in wastewater treatment plants, with its efficiency strongly affected by the presence of surfactants. This study investigates the impact of surfactants on oxygen mass transfer using a commercial fine bubble diffuser. Oxygen transfer experiments were performed under varying air flow rates and surfactant concentrations. Key parameters, including the volumetric mass transfer coefficient (kLa), gas holdup, bubble size, and interfacial area, were experimentally measured and analysed. Results show that kLa increases with air flow rate due to larger interfacial area, while the Standard Oxygen Transfer Efficiency (SOTE) decreases, particularly at higher surfactant concentrations. Surfactants promote smaller bubble sizes and higher gas holdup, thus increasing the interfacial area. However, they significantly reduce the liquid-side mass transfer coefficient (kL) by suppressing interfacial turbulence. Despite the increased interfacial area, the reduction in kL leads to lower overall oxygen transfer efficiency. These findings highlight the importance of accounting for surfactant effects in the design and operation of industrial aeration systems.
- 14 November 2025
- Published by MDPI AG in Preprints.org
Open AccessSurfactant Effects on Oxygen Transfer and Bubble Dynamics in a Fine-Bubble Diffuser Aeration Column
Aeration is one of the most energy-intensive operations in wastewater treatment plants, with its efficiency strongly affected by the presence of surfactants. This study investigates the impact of surfactants on oxygen mass transfer using a commercial fine bubble diffuser. Oxygen transfer experiments were performed under varying air flow rates and surfactant concentrations. Key parameters, including the volumetric mass transfer coefficient (kLa), gas holdup, bubble size, and interfacial area, were experimentally measured and analysed. Results show that kLa increases with air flow rate due to larger interfacial area, while the Standard Oxygen Transfer Efficiency (SOTE) decreases, particularly at higher surfactant concentrations. Surfactants promote smaller bubble sizes and higher gas holdup, thus increasing the interfacial area. However, they significantly reduce the liquid-side mass transfer coefficient (kL) by suppressing interfacial turbulence. Despite the increased interfacial area, the reduction in kL leads to lower overall oxygen transfer efficiency. These findings highlight the importance of accounting for surfactant effects in the design and operation of industrial aeration systems.