MPMathieu Perron

Mathieu Perron

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mathieu Perron has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Annissa Heniche

    Power Systems and Mathematics Hydro‐Québec Research Institute Varennes Canada

    1 shared publication
  • Claude Lafond

    Power Systems and Mathematics Hydro‐Québec Research Institute Varennes Canada

    1 shared publication
  • Esmaeil Ghahremani

    Power Systems and Mathematics Hydro‐Québec Research Institute Varennes Canada

    1 shared publication
  • Houssem Akremi

    Compensation and Interconnection System Hydro‐Québec Montréal Canada

    1 shared publication
  • Innocent Kamwa

    Power Systems and Mathematics Hydro‐Québec Research Institute Varennes Canada

    1 shared publication
  • Marcel Racine

    Automation and Protection Studies Hydro‐Québec Montréal Canada

    1 shared publication

Latest Publications

  • Open Access

    Wide‐area voltage control system of flexible AC transmission system devices to prevent voltage collapse

    by Mathieu Perron, Esmaeil Ghahremani, Annissa Heniche, Innocent Kamwa, Claude Lafond, Marcel Racine, Houssem Akremi, Philippe Cadieux, Simon Lebeau, Stéphane Landry

    Hydro‐Québec has identified wide‐area control system as a key initiative able to significantly increase the voltage stability of its grid. In this context, an innovative project for wide‐area and local voltage control of shunt compensators was initiated. Its main objective is to implement a closed‐loop control system on Hydro‐Québec's network to optimise the reactive power support from the dynamic shunt compensators. The outcome of this project is the ‘global and local control of compensators’ (GLCCs) system which is based on synchrophasor technology and intelligent electronics devices. Applied to each shunt compensator of Hydro‐Québec's network, this robust voltage control system measures voltage variations in the load area and adjusts the operation set point of each shunt compensator accordingly, thus avoiding voltage collapse resulting from extreme contingencies. The GLCC control solution was intensively tested in simulation using PSSE software. Moreover, a pilot project was commissioned on a test bench replica of the system and also tested in real time using Hydro‐Québec's Hypersim digital simulator. Field tests of the GLCC were conducted on a −230/ + 660 MVars static vars compensator. The results of this pilot project were deemed conclusive and the deployment of the new voltage control system has been initiated by Hydro‐Québec.