YHYuyao Hu

Yuyao Hu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuyao Hu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Jianlin Hu

    State Key Laboratory of Power Transmission Equipment and System Security and New Technology College of Electrical Engineering Chongqing University Chongqing 400044 People's Republic of China

    2 shared publications
  • Lichun Shu

    State Key Laboratory of Power Transmission Equipment and System Security and New Technology College of Electrical Engineering Chongqing University Chongqing 400044 People's Republic of China

    2 shared publications
  • Qin Hu

    State Key Laboratory of Power Transmission Equipment and System Security and New Technology College of Electrical Engineering Chongqing University Chongqing 400044 People's Republic of China

    2 shared publications
  • Xingliang Jiang

    State Key Laboratory of Power Transmission Equipment and System Security and New Technology College of Electrical Engineering Chongqing University Chongqing 400044 People's Republic of China

    2 shared publications
  • Zhijin Zhang

    State Key Laboratory of Power Transmission Equipment and System Security and New Technology College of Electrical Engineering Chongqing University Chongqing 400044 People's Republic of China

    2 shared publications
  • Quanlin Wang

    State Key Laboratory of Power Transmission Equipment and System Security and New Technology, College of Electrical Engineering Chongqing University Shapingba District Chongqing 400044 People's Republic of China

    1 shared publication

Latest Publications

  • Open Access

    DC flashover performance of ice‐covered insulators under complex ambient conditions

    by Yuyao Hu, Xingliang Jiang, Lichun Shu, Zhijin Zhang, Qin Hu, Jianlin Hu

    The electrical characteristics of ice‐covered insulators in coexisting conditions of high altitude, icing and pollution are a basis for external insulation selection of transmission lines in icing regions. Ice accretion on insulators has been studied for decades, while few studies focus on the flashover performance of ice‐covered insulators polluted by two types of contamination, that is the solid layer method and icing water conductivity method, simultaneously. On the basis of the investigations on DC flashover performance of ice‐covered insulators in the artificial climate chamber, the influence of different parameters, such as insulator string length, icing water conductivity, salt deposit density as well as atmospheric pressure on DC icing flashover voltage of insulator strings is studied. According to the experimental results, the relationships between the flashover voltage and each of such factors are determined and analysed. Moreover, the correction formula for DC flashover voltage of ice‐covered insulators in complex ambient conditions is proposed.


  • Open Access

    Crystallisation effect of conductive ions in freezing water during phase transition and its effect on ice flashover voltage

    by Xingliang Jiang, Yuyao Hu, Lichun Shu, Zhijin Zhang, Jianlin Hu, Qin Hu, Quanlin Wang

    Icing experiments on three units of XP 4 ‐160 insulator string are conducted to reveal the influence of the crystallisation effect of conductive ions during phase transition on melting water conductivity and ice flashover voltage, and to analyse the motion of conductive ions and its spatial distribution. The influence of different parameters, such as freezing water conductivity, electric field and pollution, on crystallisation effect is examined and analysed. Results of the tests indicate that the melting water conductivity of the ice layer and icicles is considerably greater than that of freezing water, particularly for a polluted insulator, because of the crystallisation effect. The electric field has a significant influence on the crystallisation effect, that is, the melting water conductivity under a non‐energised condition is higher than that under an energised condition. Finally, through 35 kV insulator flashover tests, the reason for the propagation of partial arcs over icicles is determined, and the flashover process is illustrated. The crystallisation effect during phase transition changes the ion distribution in a solid ice layer, thereby increasing water film conductivity, and is also a critical reason for the decline of ice flashover voltage.