Suat Ince
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Suat Ince has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Bilal Bayram
Department of Neurology, University of Health Sciences, Van Education and Research Hospital, 65000 Van, Turkey
2 shared publications - Ishak Pacal
Department of Computer Engineering, Faculty of Engineering, Igdir University, Igdir 76000, Türkiye
2 shared publications - Ali Algarni
Department of Informatics and Computer Systems, College of Computer Science, King Khalid University, Abha 61421, Saudi Arabia
1 shared publication - Erkan Veziroglu
Department of Computer Technologies, Simav Vocational School, Kutahya Dumlupinar University, 43500, Simav, Kutahya, Turkey
1 shared publication - Serhat Kiliçarslan
Department of Software Engineering, Faculty of Engineering, Bandirma Onyedi Eylül University, 10200 Balıkesir, Turkey
1 shared publication - Ömer Çelik
Igdir Universitesi
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
- 18 January 2026
- Published by Scientific Oasis in Journal of Soft Computing and Decision Analytics
- Vol. 4 (1) , 16-31
Advancing Ischemic Stroke Detection Through an In-depth Evaluation of YOLOv10 Models on Diffusion-Weighted Imaging Data
Rapid, accurate detection of acute ischemic stroke (AIS) is vital for patient outcomes. This study evaluates YOLOv10 variants using Diffusion-Weighted Imaging (DWI) data from the ISLES 2022 dataset to identify a model that optimally balances diagnostic accuracy, speed, and computational efficiency for clinical deployment. Methods: YOLOv10 variants were trained on 1652 preprocessed DWI images using transfer learning and data augmentation. Performance was assessed using precision, recall, mAP50, and inference time to evaluate each model comprehensively. Results: The YOLOv10l variant achieved the best performance with 0.933 precision, 0.783 recall, and 0.887 mAP50. YOLOv10n was fastest (0.8 ms) but less accurate, highlighting a trade-off between speed and precision. A key challenge across models was the reliable detection of smaller, less distinct stroke lesions. These findings underscore the importance of balancing accuracy and efficiency. YOLOv10l is optimal for high-precision hospital diagnostics, whereas YOLOv10n suits real-time, resource-limited settings. Future work must focus on improving the detection of small lesions to enhance clinical utility and ensure comprehensive diagnostic support. YOLOv10 is a powerful tool for automated stroke detection, with the YOLOv10l model providing a balanced solution for clinical use. Integrating such models can significantly enhance diagnostic workflows, aid clinical decisions, and ultimately improve patient outcomes in stroke care.
- 18 January 2026
- Published by Scientific Oasis in Journal of Soft Computing and Decision Analytics
- Vol. 4 (1) , 16-31
Top Cited PapersOpen AccessAdvancing Ischemic Stroke Detection Through an In-depth Evaluation of YOLOv10 Models on Diffusion-Weighted Imaging Data
Rapid, accurate detection of acute ischemic stroke (AIS) is vital for patient outcomes. This study evaluates YOLOv10 variants using Diffusion-Weighted Imaging (DWI) data from the ISLES 2022 dataset to identify a model that optimally balances diagnostic accuracy, speed, and computational efficiency for clinical deployment. Methods: YOLOv10 variants were trained on 1652 preprocessed DWI images using transfer learning and data augmentation. Performance was assessed using precision, recall, mAP50, and inference time to evaluate each model comprehensively. Results: The YOLOv10l variant achieved the best performance with 0.933 precision, 0.783 recall, and 0.887 mAP50. YOLOv10n was fastest (0.8 ms) but less accurate, highlighting a trade-off between speed and precision. A key challenge across models was the reliable detection of smaller, less distinct stroke lesions. These findings underscore the importance of balancing accuracy and efficiency. YOLOv10l is optimal for high-precision hospital diagnostics, whereas YOLOv10n suits real-time, resource-limited settings. Future work must focus on improving the detection of small lesions to enhance clinical utility and ensure comprehensive diagnostic support. YOLOv10 is a powerful tool for automated stroke detection, with the YOLOv10l model providing a balanced solution for clinical use. Integrating such models can significantly enhance diagnostic workflows, aid clinical decisions, and ultimately improve patient outcomes in stroke care.
- Top Cited PapersOpen Access
- 30 October 2025
- Published by IMR Press in Journal of Integrative Neuroscience
- Vol. 24 (10) , 40100
FA-UNet: A FasterNet and Attention-Gated Hybrid Network for Precise Ischemic Stroke Segmentation
Background: Accurate and timely segmentation of ischemic stroke lesions from diffusion-weighted imaging (DWI) is crucial for diagnosis and treatment planning. Manual segmentation is labor-intensive, time-consuming, and prone to inter-observer variability. This study aims to develop and validate a novel deep learning framework that overcomes the common trade-off between high segmentation accuracy and the computational efficiency required for practical clinical use. Methods: We developed FasterNet and Attention-Gated UNet (FA-UNet), a hybrid U-Net-based architecture. The model’s design features two key innovations: a computationally efficient FasterNet block at the bottleneck to capture global lesion context and multi-scale attention gates (MSAGs) on the skip connections to adaptively refine features and suppress noise. The model was trained and validated on the public Ischemic Stroke Lesion Segmentation (ISLES) 2022 dataset (n = 250 patients) and its performance was assessed on an independent, private test set of 600 DWI scans from 80 patients. FA-UNet’s performance was benchmarked against several state-of-the-art U-Net variants using the Dice coefficient, Intersection over Union (IoU), sensitivity, and precision as primary outcome measures. Results: On the independent test set (n = 80), the proposed FA-UNet model achieved a Dice coefficient of 0.8676 and an IoU of 0.7584. This performance surpassed all benchmarked architectures, including U-Net, U-Net3plus, and CMU-Net. Compared with the next best performing model, this represents a relative improvement of approximately 1.64% in the Dice score and 1.42% in IoU. Conclusion: The FA-UNet architecture establishes a new state-of-the-art performance benchmark for automated ischemic stroke segmentation. By effectively balancing high accuracy with computational efficiency, it offers a robust, reliable, and clinically viable tool.
- 30 October 2025
- Published by IMR Press in Journal of Integrative Neuroscience
- Vol. 24 (10) , 40100
Top Cited PapersOpen AccessFA-UNet: A FasterNet and Attention-Gated Hybrid Network for Precise Ischemic Stroke Segmentation
Background: Accurate and timely segmentation of ischemic stroke lesions from diffusion-weighted imaging (DWI) is crucial for diagnosis and treatment planning. Manual segmentation is labor-intensive, time-consuming, and prone to inter-observer variability. This study aims to develop and validate a novel deep learning framework that overcomes the common trade-off between high segmentation accuracy and the computational efficiency required for practical clinical use. Methods: We developed FasterNet and Attention-Gated UNet (FA-UNet), a hybrid U-Net-based architecture. The model’s design features two key innovations: a computationally efficient FasterNet block at the bottleneck to capture global lesion context and multi-scale attention gates (MSAGs) on the skip connections to adaptively refine features and suppress noise. The model was trained and validated on the public Ischemic Stroke Lesion Segmentation (ISLES) 2022 dataset (n = 250 patients) and its performance was assessed on an independent, private test set of 600 DWI scans from 80 patients. FA-UNet’s performance was benchmarked against several state-of-the-art U-Net variants using the Dice coefficient, Intersection over Union (IoU), sensitivity, and precision as primary outcome measures. Results: On the independent test set (n = 80), the proposed FA-UNet model achieved a Dice coefficient of 0.8676 and an IoU of 0.7584. This performance surpassed all benchmarked architectures, including U-Net, U-Net3plus, and CMU-Net. Compared with the next best performing model, this represents a relative improvement of approximately 1.64% in the Dice score and 1.42% in IoU. Conclusion: The FA-UNet architecture establishes a new state-of-the-art performance benchmark for automated ischemic stroke segmentation. By effectively balancing high accuracy with computational efficiency, it offers a robust, reliable, and clinically viable tool.