Junbo Deng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Junbo Deng has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Fang Yu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University Xi'an People's Republic of China
2 shared publicationsJiangtao Li
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University Xi'an People's Republic of China
2 shared publicationsJie Guo
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University Xi'an People's Republic of China
2 shared publicationsXiaoguang Zhu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University Xi'an People's Republic of China
2 shared publicationsYichen Liu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University Xi'an People's Republic of China
2 shared publicationsGuanjun Zhang
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University Xi'an People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 7 January 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 1232-1237
Study on overvoltage characteristics and arrester configuration strategy for ±1 100 kV HVDC transmission lines
Overvoltage caused by faults or switching is one of the decisive factors affecting the insulation level of equipment in UHVDC transmission systems. As for ±1 100 kV transmission projects, there has been no clear conclusion about the overvoltage distribution characteristics along transmission lines. This paper studies characteristics of the overvoltage distribution along ±1 100 kV transmission lines after building the simulation platform of ±1 100 kV UHVDC transmission systems with the use of PSCAD software. The typical fault conditions are simulated such as monopolar line‐to‐ground fault and line‐broken‐down fault of transmission lines. The distribution characteristics of overvoltage along the line under different faults are obtained. The simulation results show that the arresters installed along the lines can significantly reduce the switching voltage level of DC lines. The voltage‐current characteristics and the installation density of the arresters along the line have an important influence on the overvoltage suppression effect. Through the comparative analysis, a configuration scheme of arresters along the lines is proposed, which has a great effect for overvoltage suppression. The results are instructive for the design of insulation coordination in practical projects.
- 7 January 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 1232-1237
Open AccessStudy on overvoltage characteristics and arrester configuration strategy for ±1 100 kV HVDC transmission lines
Overvoltage caused by faults or switching is one of the decisive factors affecting the insulation level of equipment in UHVDC transmission systems. As for ±1 100 kV transmission projects, there has been no clear conclusion about the overvoltage distribution characteristics along transmission lines. This paper studies characteristics of the overvoltage distribution along ±1 100 kV transmission lines after building the simulation platform of ±1 100 kV UHVDC transmission systems with the use of PSCAD software. The typical fault conditions are simulated such as monopolar line‐to‐ground fault and line‐broken‐down fault of transmission lines. The distribution characteristics of overvoltage along the line under different faults are obtained. The simulation results show that the arresters installed along the lines can significantly reduce the switching voltage level of DC lines. The voltage‐current characteristics and the installation density of the arresters along the line have an important influence on the overvoltage suppression effect. Through the comparative analysis, a configuration scheme of arresters along the lines is proposed, which has a great effect for overvoltage suppression. The results are instructive for the design of insulation coordination in practical projects.
- Open Access
- 17 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 1016-1019
Research on protection block strategy of grounding faults in HVDC converter station
DC grounding fault is a typical fault for HVDC system. In order to obtain smoother, faster, and more secure transient process, the DC protection block strategy is used to remove and isolate the converter to prevent the accident enlargement and reduce the impact on devices and power grid when the grounding fault is detected. Two main strategies are commonly taken in this situation: the X block for not >±500 kV and the S block for ±800 kV. There is no specific principle on the strategy choosing for ±1100 kV UHVDC system with hierarchical connection mode. Changji–Guquan ±1100 kV UHVDC transmission project adopting hierarchical connection mode at receiving end. In this study, the effects of different DC block strategies when grounding faults occurred in both converter stations are compared based on PSCAD simulation. The simulation results indicate that the overvoltage at rectifier side has two stages while the overvoltage at inverter side has only one. Taking S block strategy can cause lower overvoltage but longer oscillation duration on grounding current. The proper block strategy for ±1100 kV UHVDC grounding faults is adopting S block at rectifier side and X block at inverter side.
- 17 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 1016-1019
Open AccessResearch on protection block strategy of grounding faults in HVDC converter station
DC grounding fault is a typical fault for HVDC system. In order to obtain smoother, faster, and more secure transient process, the DC protection block strategy is used to remove and isolate the converter to prevent the accident enlargement and reduce the impact on devices and power grid when the grounding fault is detected. Two main strategies are commonly taken in this situation: the X block for not >±500 kV and the S block for ±800 kV. There is no specific principle on the strategy choosing for ±1100 kV UHVDC system with hierarchical connection mode. Changji–Guquan ±1100 kV UHVDC transmission project adopting hierarchical connection mode at receiving end. In this study, the effects of different DC block strategies when grounding faults occurred in both converter stations are compared based on PSCAD simulation. The simulation results indicate that the overvoltage at rectifier side has two stages while the overvoltage at inverter side has only one. Taking S block strategy can cause lower overvoltage but longer oscillation duration on grounding current. The proper block strategy for ±1100 kV UHVDC grounding faults is adopting S block at rectifier side and X block at inverter side.