Klemen Dezelak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Klemen Dezelak has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Alena Otcenasova
Department of Power Electrical Systems Faculty of Electrical Engineering University of Zilina Univerzitna 8215/1 010 26 Zilina Slovakia
1 shared publication- Marek Hoger
University of ilina,Faculty of Electrical Engineering and Information Technology,ilina,Slovakia
1 shared publication Peter Bracinik
Department of Power Electrical Systems Faculty of Electrical Engineering University of Zilina Univerzitna 8215/1 010 26 Zilina Slovakia
1 shared publication
Latest Publications
- Open Access
- 1 April 2016
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 10 (4) , 522-530
Comparison between the particle swarm optimisation and differential evolution approaches for the optimal proportional–integral controllers design during photovoltaic power plants modelling
This study deals with photovoltaic power plant modelling and its integration within the distribution network. It presents a simulation model of a whole photovoltaic power plant including the solar cells, boost converter with maximal power point tracking, voltage‐oriented control and inductor‐capacitor‐inductor (LCL) filter. In such a sense, the applied inverter has many advantages such as a controllable power factor and sinusoidal input current, while the switching frequency of the power switch is relatively high. Therefore, it could cause high‐frequency harmonics around the switching frequency. The traditional way of solving these problems is the usage of LCL filters, where the basic requirement is to achieve sufficient filtering with inductor and capacitor values as small as possible. In addition, emphasis is given to a comparison between two optimisation methods – particle swarm optimisation and differential evolution that are used for the parameters of proportional–integral (PI) controllers determination. These PI controllers represent the main part of the voltage‐oriented control.
- 1 April 2016
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 10 (4) , 522-530
Open AccessComparison between the particle swarm optimisation and differential evolution approaches for the optimal proportional–integral controllers design during photovoltaic power plants modelling
This study deals with photovoltaic power plant modelling and its integration within the distribution network. It presents a simulation model of a whole photovoltaic power plant including the solar cells, boost converter with maximal power point tracking, voltage‐oriented control and inductor‐capacitor‐inductor (LCL) filter. In such a sense, the applied inverter has many advantages such as a controllable power factor and sinusoidal input current, while the switching frequency of the power switch is relatively high. Therefore, it could cause high‐frequency harmonics around the switching frequency. The traditional way of solving these problems is the usage of LCL filters, where the basic requirement is to achieve sufficient filtering with inductor and capacitor values as small as possible. In addition, emphasis is given to a comparison between two optimisation methods – particle swarm optimisation and differential evolution that are used for the parameters of proportional–integral (PI) controllers determination. These PI controllers represent the main part of the voltage‐oriented control.