Payam Rabbanifar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Payam Rabbanifar has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
Nima Amjady
Department of Electrical Engineering Semnan University Semnan Iran
1 shared publication
Latest Publications
- Open Access
- 2 July 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (17) , 3548-3560
Frequency‐constrained unit‐commitment using analytical solutions for system frequency responses considering generator contingencies
The frequency responses of a power system following a generator outage are closely related to the commitment states of generators, which describe the droop and inertial characteristics and system pre‐contingency power dispatch. This study presents a new model to estimate the transient and steady state frequency responses of two‐area power systems at any moment following the loss of an online generator. In the proposed model, the deviations of tie‐flow, area frequencies and rate of change of area frequencies as well as the extreme values of these functions and their associated time of occurrence following the outage of a generation unit are derived as modified analytical functions. A new approach is also proposed to linearise the modified extreme deviations based on pseudo‐Boolean function theorem. In addition, a frequency‐constrained unit commitment model with modified frequency‐dependent constraints incorporating primary frequency regulation reserve is presented as a mixed‐integer linear programming problem. The results indicate that the proposed method gives acceptable approximations for post‐contingency responses and can ensure power system security from frequency viewpoint.
- 2 July 2020
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 14 (17) , 3548-3560
Open AccessFrequency‐constrained unit‐commitment using analytical solutions for system frequency responses considering generator contingencies
The frequency responses of a power system following a generator outage are closely related to the commitment states of generators, which describe the droop and inertial characteristics and system pre‐contingency power dispatch. This study presents a new model to estimate the transient and steady state frequency responses of two‐area power systems at any moment following the loss of an online generator. In the proposed model, the deviations of tie‐flow, area frequencies and rate of change of area frequencies as well as the extreme values of these functions and their associated time of occurrence following the outage of a generation unit are derived as modified analytical functions. A new approach is also proposed to linearise the modified extreme deviations based on pseudo‐Boolean function theorem. In addition, a frequency‐constrained unit commitment model with modified frequency‐dependent constraints incorporating primary frequency regulation reserve is presented as a mixed‐integer linear programming problem. The results indicate that the proposed method gives acceptable approximations for post‐contingency responses and can ensure power system security from frequency viewpoint.