Shuai Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shuai Liang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Gangui Yan
College of Electrical Engineering Northeast Electric Power University Jilin People's Republic of China
1 shared publication- Guoju Zhang
Power grid technology laboratory, Institute of electrical engineering, Chinese academy of sciences, Beijing, China
1 shared publication - Jinglei Deng
School of Electrical Engineering and Automation, Wuhan University, Wuhan 430072, China
1 shared publication - Junpeng Deng
Hubei Engineering and Technology Research Center for AC/DC Intelligent Distribution Network 1 , Wuhan 430000
1 shared publication - Liangzhong Yao
Wuhan University
1 shared publication Qi Jia
College of Electrical Engineering Northeast Electric Power University Jilin People's Republic of China
1 shared publication
Latest Publications
- Open Access
- 26 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (23) , 4651
A Novel Strategy for Preventing Commutation Failures During Fault Recovery Using PLL Phase Angle Error Compensation
Existing studies on commutation failure during fault recovery (CFFR) in line-commutated converter high-voltage direct current (LCC-HVDC) systems often neglect the critical influence of phase-locked loop phase tracking error (PLL-PTE) and fail to provide effective control strategies to address this issue. This paper investigates the influence of PLL-PTE on CFFR through electromagnetic transient simulations based on a modified CIGRE benchmark model. The study reveals that phase angle jump (PAJ) caused by DC power fluctuations (DPF) and AC network reconfigurations (ANR) is the fundamental source of PLL-PTE, which in turn leads to the occurrence of CFFR. To mitigate this, a novel control strategy is proposed that dynamically adjusts the extinction angle based on historical and predicted PAJ data. Simulation results demonstrate that the proposed method effectively suppresses CFFR under various fault conditions, including different fault types, locations, resistances, and initiation times. Compared with existing control schemes, the proposed approach avoids adverse side effects while exhibiting strong robustness and adaptability. The proposed control strategy significantly enhances the stability and reliability of LCC-HVDC systems, offering great potential for practical application in increasingly complex power grid environments.
- 26 November 2025
- Published by MDPI AG in Electronics
- Vol. 14 (23) , 4651
Open AccessA Novel Strategy for Preventing Commutation Failures During Fault Recovery Using PLL Phase Angle Error Compensation
Existing studies on commutation failure during fault recovery (CFFR) in line-commutated converter high-voltage direct current (LCC-HVDC) systems often neglect the critical influence of phase-locked loop phase tracking error (PLL-PTE) and fail to provide effective control strategies to address this issue. This paper investigates the influence of PLL-PTE on CFFR through electromagnetic transient simulations based on a modified CIGRE benchmark model. The study reveals that phase angle jump (PAJ) caused by DC power fluctuations (DPF) and AC network reconfigurations (ANR) is the fundamental source of PLL-PTE, which in turn leads to the occurrence of CFFR. To mitigate this, a novel control strategy is proposed that dynamically adjusts the extinction angle based on historical and predicted PAJ data. Simulation results demonstrate that the proposed method effectively suppresses CFFR under various fault conditions, including different fault types, locations, resistances, and initiation times. Compared with existing control schemes, the proposed approach avoids adverse side effects while exhibiting strong robustness and adaptability. The proposed control strategy significantly enhances the stability and reliability of LCC-HVDC systems, offering great potential for practical application in increasingly complex power grid environments.
- Open Access
- 14 January 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 3383-3387
Novel adapted de‐loading control strategy for PV generation participating in grid frequency regulation
Existence PV generation mostly operates under the Maximum Power Point Tracking (MPPT) mode and has no ability to increase or decrease active power, accordingly, PV generation does not participate in grid frequency regulation. Due to an increasing penetration of grid‐connected PV generation, when a frequency contingency event occurs, grid may have neither enough inertia response nor governor support and frequency deviation may have a risk of exceeding the limit. Therefore, a novel adapted de‐loading control strategy without MPPT for grid‐connected inverters is proposed here. This control strategy provides a reserve power in PV system to meet the frequency control demand and an online output Active Power‐Voltage Matching (APVM) technique, which is generated as a control flowchart, is implemented in this control strategy to make it possible to adjust PV output voltage performance matching different active power demand with different operation modes. The proposed control strategy of PVs is simulated using PSCAD/EMTDC Software. Results verify the correctness and effectiveness of the proposed adapted de‐loading control strategy under several operating conditions.
- 14 January 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 3383-3387
Open AccessNovel adapted de‐loading control strategy for PV generation participating in grid frequency regulation
Existence PV generation mostly operates under the Maximum Power Point Tracking (MPPT) mode and has no ability to increase or decrease active power, accordingly, PV generation does not participate in grid frequency regulation. Due to an increasing penetration of grid‐connected PV generation, when a frequency contingency event occurs, grid may have neither enough inertia response nor governor support and frequency deviation may have a risk of exceeding the limit. Therefore, a novel adapted de‐loading control strategy without MPPT for grid‐connected inverters is proposed here. This control strategy provides a reserve power in PV system to meet the frequency control demand and an online output Active Power‐Voltage Matching (APVM) technique, which is generated as a control flowchart, is implemented in this control strategy to make it possible to adjust PV output voltage performance matching different active power demand with different operation modes. The proposed control strategy of PVs is simulated using PSCAD/EMTDC Software. Results verify the correctness and effectiveness of the proposed adapted de‐loading control strategy under several operating conditions.