Neville J. McDonald
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Neville J. McDonald has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Neves Cavalcanti
Department of Cariology, Restorative Sciences and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, MI, USA
1 shared publication - Felipe Gonçalves Belladonna
Department of Endodontics Fluminense Federal University Rio de Janeiro Brazil
1 shared publication Fisher Pham
School of Dentistry University of Michigan Ann Arbor Michigan USA
1 shared publication- Hajime Sasaki
Department of Cariology, Restorative Sciences, and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, USA
1 shared publication - Lucas Peixoto de Araújo
Department of Cariology, Restorative Sciences, and Endodontics, School of Dentistry University of Michigan Ann Arbor Michigan USA
1 shared publication - Marco Antonio Bottino
Department of Cariology, Restorative Sciences, and Endodontics, School of Dentistry, University of Michigan, Ann Arbor, MI 48109, USA
1 shared publication
Latest Publications
- Open Access
- 15 November 2026
- Published by Wiley in Australian Endodontic Journal
Can Contemporary NiTi Systems Reach the Full Working Length Without Prior Glide Path Preparation? A Scoping Review
This scoping review mapped evidence on nickel‐titanium instrumentation without a prior glide path across kinematics, models and outcomes. Six databases were searched from inception to August 2026 for studies using rotary or reciprocating nickel‐titanium instruments without a prior glide path and reporting working length attainment or a procedural outcome. Sixty‐nine studies were included, 65 laboratory and four clinical, none providing a randomised comparison of glide‐path omission. Thirteen addressed reaching the full working length, eleven using single‐file reciprocating instruments, which reached it in 85.6%–96.3% of 1773 canals clinically and 70.9%–100% in the laboratory. The remaining 56 reported procedural outcomes. Kinematics, alloy and taper covaried, and the no‐glide‐path condition was defined inconsistently across different systems. Single‐file reciprocating instruments have reached the full working length without a prior glide path in most canals studied, but differences in anatomy, instrument systems and operative protocols limit generalisation.
- 15 November 2026
- Published by Wiley in Australian Endodontic Journal
Open AccessCan Contemporary NiTi Systems Reach the Full Working Length Without Prior Glide Path Preparation? A Scoping Review
This scoping review mapped evidence on nickel‐titanium instrumentation without a prior glide path across kinematics, models and outcomes. Six databases were searched from inception to August 2026 for studies using rotary or reciprocating nickel‐titanium instruments without a prior glide path and reporting working length attainment or a procedural outcome. Sixty‐nine studies were included, 65 laboratory and four clinical, none providing a randomised comparison of glide‐path omission. Thirteen addressed reaching the full working length, eleven using single‐file reciprocating instruments, which reached it in 85.6%–96.3% of 1773 canals clinically and 70.9%–100% in the laboratory. The remaining 56 reported procedural outcomes. Kinematics, alloy and taper covaried, and the no‐glide‐path condition was defined inconsistently across different systems. Single‐file reciprocating instruments have reached the full working length without a prior glide path in most canals studied, but differences in anatomy, instrument systems and operative protocols limit generalisation.
- Open Access
- 17 November 2025
- Published by Springer Nature in Odontology
- Vol. 114 (4) , 1-10
Multifunctional aloe vera-based biomaterial for vital pulp therapy: an in vivo evaluation
This study aimed to evaluate the effects of Gelatin methacryloyl/Aloe vera (GelMA/AV) scaffolds, both alone and in combination with mineral trioxide aggregate (MTA), on pulp inflammatory response and mineralized tissue formation in a rat model of pulp exposure. GelMA/AV nanofibers (70:30) were fabricated via electrospinning and photocrosslinked. Twenty-four rats were randomly assigned to three groups ( n = 8/ group): GelMA/AV, GelMA/AV + MTA, and MTA (control). Following pulp exposure of the first upper molars ( n = 2/animal), the materials were placed over the exposed pulp as the pulp capping agent, and MTA was applied or not, depending on the group. The cavities were then sealed with glass ionomer. Animals were euthanized at 7 or 28 days post-procedure for histological, immunohistochemical, and micro-computed tomography (micro-CT) analyses. Data were analyzed using one-way or two-way ANOVA at a 5% significance level. Micro-CT analysis at 28 days revealed new hard tissue formation in the pulp chamber across all groups. GelMA/AV + MTA demonstrated comparable mineralized volume and tissue mineral density to MTA. Histologically, the GelMA/AV + MTA group exhibited a significantly lower cell count than the MTA and GelMA/AV groups at 28 days. However, for macrophage polarization, the GelMA/AV + MTA exhibited a similar expression of CD163-positive (M2) and iNOS-positive (M1) cells compared to the MTA. Lastly, GelMA/AV + MTA also showed expression of nestin and DMP1 at 28 days, indicating active mineralization. In conclusion, a thin GelMA/AV sublayer beneath MTA preserves MTA-driven mineralization but does not reduce pulp inflammation or enhance mineralization beyond MTA in this model. Optimization of AV dosing/formulation and longer follow-up are necessary before clinical translation.
- 17 November 2025
- Published by Springer Nature in Odontology
- Vol. 114 (4) , 1-10
Open AccessMultifunctional aloe vera-based biomaterial for vital pulp therapy: an in vivo evaluation
This study aimed to evaluate the effects of Gelatin methacryloyl/Aloe vera (GelMA/AV) scaffolds, both alone and in combination with mineral trioxide aggregate (MTA), on pulp inflammatory response and mineralized tissue formation in a rat model of pulp exposure. GelMA/AV nanofibers (70:30) were fabricated via electrospinning and photocrosslinked. Twenty-four rats were randomly assigned to three groups ( n = 8/ group): GelMA/AV, GelMA/AV + MTA, and MTA (control). Following pulp exposure of the first upper molars ( n = 2/animal), the materials were placed over the exposed pulp as the pulp capping agent, and MTA was applied or not, depending on the group. The cavities were then sealed with glass ionomer. Animals were euthanized at 7 or 28 days post-procedure for histological, immunohistochemical, and micro-computed tomography (micro-CT) analyses. Data were analyzed using one-way or two-way ANOVA at a 5% significance level. Micro-CT analysis at 28 days revealed new hard tissue formation in the pulp chamber across all groups. GelMA/AV + MTA demonstrated comparable mineralized volume and tissue mineral density to MTA. Histologically, the GelMA/AV + MTA group exhibited a significantly lower cell count than the MTA and GelMA/AV groups at 28 days. However, for macrophage polarization, the GelMA/AV + MTA exhibited a similar expression of CD163-positive (M2) and iNOS-positive (M1) cells compared to the MTA. Lastly, GelMA/AV + MTA also showed expression of nestin and DMP1 at 28 days, indicating active mineralization. In conclusion, a thin GelMA/AV sublayer beneath MTA preserves MTA-driven mineralization but does not reduce pulp inflammation or enhance mineralization beyond MTA in this model. Optimization of AV dosing/formulation and longer follow-up are necessary before clinical translation.