Yu-Min Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yu-Min Lin has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Cheng Chi Wang
Department of Orthopedics, Taichung Veterans General Hospital, Taichung, Taiwan
1 shared publication - Chung-Yuh Tzeng
Department of Orthopedics, Taichung Veterans General Hospital, Taichung 407, Taiwan
1 shared publication - Kuan-Kai Tung
Department of Orthopedics, Taichung Veterans General Hospital, Taichung 40705, Taiwan
1 shared publication - Kun-Hui Chen
Department of Orthopaedics, Taichung Veterans General Hospital, Taichung 40705, Taiwan
1 shared publication - Yuan-Shao Chen
Department of Orthopaedic Surgery Taichung Veterans General Hospital Taichung Taiwan
1 shared publication Yuan-Ya Liao
Taichung, Taiwan
1 shared publication
Latest Publications
- Open Access
- 1 September 2026
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 10 (9)
Letter to the Editor: Great Minds Think Alike
Was not provided for this article.
- 1 September 2026
- Published by Wolters Kluwer Health in JAAOS: Global Research and Reviews
- Vol. 10 (9)
Open AccessLetter to the Editor: Great Minds Think Alike
Was not provided for this article.
- Open Access
- 1 January 2025
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2025 (1)
Retrieval of Entrapped Broken Guide Wire in the Femoral Head and Hip Joint Using Alligator Forceps: A Case Report and Technique Note
The guide wire plays a crucial role in core decompression procedures for avascular necrosis of the femoral head and fixation of femoral neck fractures using dynamic hip screws (DHSs) or cannulated screws. Although guide wire breakage during surgery is extremely rare, there have been instances where the distal end of the guide wire has fractured and becomes trapped within the fractured femoral head or hip joint. This can occur due to technical errors or poor quality of the guide wire used. The removal of the broken guide wire from the femoral head presents a challenging and complex task that requires precision and efficiency. In this report, we present a safe and efficient method to remove a broken guide wire entrapped within the femoral head and hip joint using alligator forceps. Under the guidance of an image intensifier, the broken guide wire was successfully extracted using this specialized instrument. By sharing this rare case, our goal is to raise awareness among surgeons about the possible complications associated with core decompression procedures and to highlight the importance of preventive measures. Furthermore, we introduce a reliable and alternative technique for removing broken guide wires, providing surgeons with an easier and more efficient approach.
- 1 January 2025
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2025 (1)
Open AccessRetrieval of Entrapped Broken Guide Wire in the Femoral Head and Hip Joint Using Alligator Forceps: A Case Report and Technique Note
The guide wire plays a crucial role in core decompression procedures for avascular necrosis of the femoral head and fixation of femoral neck fractures using dynamic hip screws (DHSs) or cannulated screws. Although guide wire breakage during surgery is extremely rare, there have been instances where the distal end of the guide wire has fractured and becomes trapped within the fractured femoral head or hip joint. This can occur due to technical errors or poor quality of the guide wire used. The removal of the broken guide wire from the femoral head presents a challenging and complex task that requires precision and efficiency. In this report, we present a safe and efficient method to remove a broken guide wire entrapped within the femoral head and hip joint using alligator forceps. Under the guidance of an image intensifier, the broken guide wire was successfully extracted using this specialized instrument. By sharing this rare case, our goal is to raise awareness among surgeons about the possible complications associated with core decompression procedures and to highlight the importance of preventive measures. Furthermore, we introduce a reliable and alternative technique for removing broken guide wires, providing surgeons with an easier and more efficient approach.