ZWZhengwei Wang

Zhengwei Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhengwei Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reverse Osmosis Membrane Cleaning Optimization from Textile Dyeing Wastewater Reuse Applications

    by Zhengwei Wang, Rulu Ouyang, Guorui Zhang, Chunhai Wei, Shiming Ji, Qixuan Li, Chunyang Tao, Hongwei Rong

    Reverse osmosis (RO) is the key process for textile dyeing wastewater reuse applications. Membrane fouling reduces both permeability and rejection capability, negatively affecting the technological economy of RO process. Membrane cleaning is critical to recovery of the permeability of fouled RO membranes. Based on multi-batch filtration and cleaning experiments, this study systematically evaluated the RO membrane fouling potential of pre-treated textile dyeing wastewater by a membrane bioreactor and the recovery performance of fouled RO membranes after different cleaning methods. A significant decline (more than 15%) in RO membrane permeability occurred after RO membrane permeate production of 625 L/m2 at a water recovery ratio of 60%. Protein-like substances and soluble microbial products were identified as the primary organic foulants via three-dimensional fluorescence excitation-emission matrix spectrometry (3D-FEEM). The single forward flushing with either pure water, acid, alkaline, or sodium hypochlorite solutions with a low active chlorine concentration showed very limited recovery of fouled RO membrane permeability. The combined forward flushing with acid followed by alkaline solutions restored fouled membrane permeability by up to 87% of a new RO membrane. The addition of pure water backwashing at a transmembrane pressure (TMP) of 0.5 MPa after both acid and alkaline solutions combined forward flushing restored fouled membrane permeability by up to 97% of a new RO membrane but deteriorated the rejection capability of the RO membrane. The backwashing parameters were further optimized at a TMP of 0.125 MPa and crossflow velocity (CFV) of 0.5 m/s, achieving fouled RO membrane permeability by up to 96% of a new RO membrane, and there were no negative effects on the rejection capability of the RO membrane. Alkaline forward flushing followed by pure water backwashing was the dominant contributor for fouled RO membrane permeability recovery. A preliminary economic analysis showed that the total chemical cost per RO production was 0.763 CNY/m3 and could be further reduced via removing acid cleaning and replacing combined alkaline flushing and pure water backwashing with alkaline backwashing.


  • Open Access

    Reverse Osmosis Membrane Cleaning Optimization from Textile Dyeing Wastewater Reuse Application

    by Zhengwei Wang, Rulu Ouyang, Guorui Zhang, Chun-Hai Wei, Shiming Ji, Qixuan Li, Chunyang Tao, Hongwei Rong

    Based on multi-batch filtration and cleaning experiments, this study systematically evaluated the fouling potential of pre-treated textile dyeing wastewater by membrane bioreactor on reverse osmosis (RO) membranes and the recovery performance of fouled RO membranes after different cleaning methods. After a permeate production of 625 L/m², continuous foulants accumulation resulted in a significant decline in RO membrane permeability. Protein-like substances and sol-uble microbial products were identified as the primary organic foulants via three-dimensional fluorescence excitation-emission matrix spectrometry (3D-FEEM). The single forward flushing with pure water, acid solution (pH 3.5), alkaline solution (pH 10.5), and sodium hypochlorite with low effective chlorine concentration (1-2 mg/L) showed very limited recovery of fouled RO membrane permeability. The combined forward flushing with acid solution (pH 2) followed by alkaline solution (pH 11.5) restored fouled membrane permeability up to 87% of new RO mem-brane. The addition of pure water backwashing at transmembrane pressure of 0.5 MPa after both acid and alkaline combined forward flushing restored fouled membrane permeability up to 97% of new RO membrane but deteriorated the rejection capacity of RO membrane. The backwashing parameters were further optimized as transmembrane pressure of 0.5 MPa and crossflow veloci-ty of 0.5 m/s, achieving fouled membrane permeability up to 96% of new RO membrane and no negative effects on the rejection capacity of RO membrane. Therefore, the combined cleaning of acid forward flushing → pure water backwashing → alkaline forward flushing → pure water backwashing was proposed for RO membrane cleaning from textile dyeing wastewater reuse application.