Eric Sejor
Research Subjects
Research Interests
Eric Sejor has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Antonia Agapi Pontiki
School of Biomedical Engineering & Imaging Sciences, King’s College London, St Thomas Hospital, London SE1 7EH, UK
2 shared publications - Calum Byrne
St Thomas Hospital, London SE1 7EH, UK
2 shared publications - Camille Benoist
Caranx Medical, 400 Promenade des Anglais, 06200 Nice, France
2 shared publications - Carlo Saija
School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
2 shared publications - Flavie Przybylski
Caranx Medical, 400 Promenade des Anglais, 06200 Nice, France
2 shared publications - Giulio Cerruti
Caranx Medical, 400 Promenade des Anglais, 06200 Nice, France
2 shared publications
Latest Publications
- Open Access
- 16 January 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (2) , 933
Development and Evaluation of a Reusable Self-Healing Ultrasound Phantom for Vascular Access
Ultrasound-guided femoral vascular access (UFVA) is a crucial step in cardiovascular intervention, yet training models remain costly, anatomically limited, or insufficiently durable. This research aimed to develop and evaluate a reusable, self-healing vascularised leg phantom in collaboration with clinicians. This bifurcating vascular model was cast in Plastisol using a customisable silicone mould design. The material exhibited a Shore OO hardness of 18.0 ± 2.2, a speed of sound of 1454 ± 15 m/s, an acoustic attenuation of 1.66 ± 0.02 × 106 kg/m2s, and healed 18G needle lesions within 3 h. Training capabilities were evaluated in a workshop involving 18 medical students: FVA times improved by more than 60% after 5 min of free practice. Qualitative feedback was collected from 31 medical educators via a seven-question Likert survey, with most reporting they would adopt the phantom for teaching. Phantoms cost £7.87 for materials, yet educators valued the models at £100–£500, underscoring its perceived utility. Compared to commercial alternatives, this in-house production approach reduced costs by 10–60 times, achieving comparable durability and anatomical fidelity. This study establishes a scalable, ultra-low-cost method for producing anatomically realistic, self-healing vascular phantoms, validated for effective skill acquisition in both educational and research settings.
- 16 January 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (2) , 933
Open AccessDevelopment and Evaluation of a Reusable Self-Healing Ultrasound Phantom for Vascular Access
Ultrasound-guided femoral vascular access (UFVA) is a crucial step in cardiovascular intervention, yet training models remain costly, anatomically limited, or insufficiently durable. This research aimed to develop and evaluate a reusable, self-healing vascularised leg phantom in collaboration with clinicians. This bifurcating vascular model was cast in Plastisol using a customisable silicone mould design. The material exhibited a Shore OO hardness of 18.0 ± 2.2, a speed of sound of 1454 ± 15 m/s, an acoustic attenuation of 1.66 ± 0.02 × 106 kg/m2s, and healed 18G needle lesions within 3 h. Training capabilities were evaluated in a workshop involving 18 medical students: FVA times improved by more than 60% after 5 min of free practice. Qualitative feedback was collected from 31 medical educators via a seven-question Likert survey, with most reporting they would adopt the phantom for teaching. Phantoms cost £7.87 for materials, yet educators valued the models at £100–£500, underscoring its perceived utility. Compared to commercial alternatives, this in-house production approach reduced costs by 10–60 times, achieving comparable durability and anatomical fidelity. This study establishes a scalable, ultra-low-cost method for producing anatomically realistic, self-healing vascular phantoms, validated for effective skill acquisition in both educational and research settings.
- Open Access
- 17 November 2025
- Published by Springer Nature in Research Square
Development and Evaluation of a Reusable Self-Healing Phantom for Ultrasound-Guided Femoral Vascular Access
Purpose :: Femoral vascular access is a common and often crucial step for cardiovascular intervention. With the growing demand for treatment, increasing pressure is placed on centres to develop new technologies and train more operators. Phantoms have been shown to have positive impacts on training across multiple fields of medicine. Methods :: Using an informed selection of materials, a vascularised leg phantom was developed in collaboration with clinicians. The material properties were investigated and the ability of the phantom to withstand multiple needle punctures was examined. The phantom was then evaluated in a training workshop with 18 medical students, tracking their procedural time before and after 5 minutes of practice. In a separate evaluation, the phantom was demonstrated to 31 medical educators who provided structured feedback using a 7-question survey via a 5-point Likert scale. Results :: Material analysis showed that the phantom had a OO shore hardness of 18.0±2.2, a speed of sound of 1454±15m/s, and could recover from 18-20G needle damage within three hours. Results showed that most students improved their vascular access time by over 60\% after 5 minutes of free practice on the phantom. Most educators said that they would use this phantom for training operators before and whilst training on patients. The total material costs for this phantom were £7.87, yet medical educators valued it at £100-£500 on average. Conclusion :: The methods hereby described propose a viable solution for crafting custom vascular access phantoms for industrial manufacturers, research centres, and training centres with manufacturing capabilities, costing many times less than existing commercial solutions. The phantom was shown to have a positive impact on students, and educators reported they would use it for training. Beyond education, the realistic anatomy, physical properties, and training capabilities achieved with these simple low-cost methods could find numerous applications in academic or industrial research.
- 17 November 2025
- Published by Springer Nature in Research Square
Open AccessDevelopment and Evaluation of a Reusable Self-Healing Phantom for Ultrasound-Guided Femoral Vascular Access
Purpose :: Femoral vascular access is a common and often crucial step for cardiovascular intervention. With the growing demand for treatment, increasing pressure is placed on centres to develop new technologies and train more operators. Phantoms have been shown to have positive impacts on training across multiple fields of medicine. Methods :: Using an informed selection of materials, a vascularised leg phantom was developed in collaboration with clinicians. The material properties were investigated and the ability of the phantom to withstand multiple needle punctures was examined. The phantom was then evaluated in a training workshop with 18 medical students, tracking their procedural time before and after 5 minutes of practice. In a separate evaluation, the phantom was demonstrated to 31 medical educators who provided structured feedback using a 7-question survey via a 5-point Likert scale. Results :: Material analysis showed that the phantom had a OO shore hardness of 18.0±2.2, a speed of sound of 1454±15m/s, and could recover from 18-20G needle damage within three hours. Results showed that most students improved their vascular access time by over 60\% after 5 minutes of free practice on the phantom. Most educators said that they would use this phantom for training operators before and whilst training on patients. The total material costs for this phantom were £7.87, yet medical educators valued it at £100-£500 on average. Conclusion :: The methods hereby described propose a viable solution for crafting custom vascular access phantoms for industrial manufacturers, research centres, and training centres with manufacturing capabilities, costing many times less than existing commercial solutions. The phantom was shown to have a positive impact on students, and educators reported they would use it for training. Beyond education, the realistic anatomy, physical properties, and training capabilities achieved with these simple low-cost methods could find numerous applications in academic or industrial research.