Heidy Daumas
Research Subjects
Research Interests
Heidy Daumas has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Rochelle Ackerley
Aix Marseille Univ, CNRS, CRPN (Centre de Recherche en Psychologie et Neurosciences – UMR 7077), Marseille, France
2 shared publications - Sarah Bonnet
CNRS, Centre de Recherche en Psychologie et Neurosciences (CRPN), UMR 7077, Aix Marseille Univ, CNRS, CRPN (Centre de Recherche en Psychologie et Neurosciences - UMR 7077), Marseille, France
2 shared publications Iuliia Zhurakovskaia
Haptify (formerly V.RTU), Marseille, France
1 shared publication- Rebecca Ericsson
Aix Marseille Univ, CNRS, CRPN (Centre de Recherche en Psychologie et Neurosciences – UMR 7077), Marseille, France
1 shared publication - Roger Holmes Watkins
Aix Marseille Univ, CNRS, CRPN (Centre de Recherche en Psychologie et Neurosciences – UMR 7077), Marseille, France
1 shared publication
Latest Publications
- Open Access
- 18 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 2639-2649
Impact of Sensory Haptic Vibrotactile Feedback on Manual Dexterity in Augmented Reality
The use of immersive environments is increasing, especially in rehabilitation and other areas, like sports and gaming. Tasks performed in virtual/augmented reality (VR/AR) often have poorer motor performance, in part due to reduced tactile and proprioceptive inputs. We investigated whether vibrotactile haptic feedback could enhance motor performance within AR. We used the Box and Block Test (BBT) to investigate manual dexterity, where participants moved cubes over a partition using one hand. Participants performed the task in 8 conditions: Real, AR without feedback, and AR with haptic wristband or ring vibrotactile feedback using different vibration patterns (Impulse, Continuous, Hybrid). Movement features were extracted and machine learning was used to classify the experimental conditions. Results revealed that performance was consistently lower in the AR environment compared to the physical BBT. The conditions with the haptic wristband feedback gave similar performance, compared to the AR condition without haptic feedback, in terms of number of cubes moved and successful grasp rate. Conversely, conditions using the ring showed lower performance compared to AR conditions without haptics and the wristband conditions. Motion analysis of the movement trajectory revealed that using vibrotactile devices, particularly the ring, produced slower and shorter movements, as compared to AR alone. A Gradient Boosting machine learning model did not distinguish between all conditions, showing only some accuracy between AR, wristband, and ring conditions. Our study highlights the challenges of integrating haptic sensory enhancements in AR training environments, advocating a nuanced approach to developing haptic feedback systems that complement AR technologies more effectively.
- 18 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 34 (15344320) , 2639-2649
Open AccessImpact of Sensory Haptic Vibrotactile Feedback on Manual Dexterity in Augmented Reality
The use of immersive environments is increasing, especially in rehabilitation and other areas, like sports and gaming. Tasks performed in virtual/augmented reality (VR/AR) often have poorer motor performance, in part due to reduced tactile and proprioceptive inputs. We investigated whether vibrotactile haptic feedback could enhance motor performance within AR. We used the Box and Block Test (BBT) to investigate manual dexterity, where participants moved cubes over a partition using one hand. Participants performed the task in 8 conditions: Real, AR without feedback, and AR with haptic wristband or ring vibrotactile feedback using different vibration patterns (Impulse, Continuous, Hybrid). Movement features were extracted and machine learning was used to classify the experimental conditions. Results revealed that performance was consistently lower in the AR environment compared to the physical BBT. The conditions with the haptic wristband feedback gave similar performance, compared to the AR condition without haptic feedback, in terms of number of cubes moved and successful grasp rate. Conversely, conditions using the ring showed lower performance compared to AR conditions without haptics and the wristband conditions. Motion analysis of the movement trajectory revealed that using vibrotactile devices, particularly the ring, produced slower and shorter movements, as compared to AR alone. A Gradient Boosting machine learning model did not distinguish between all conditions, showing only some accuracy between AR, wristband, and ring conditions. Our study highlights the challenges of integrating haptic sensory enhancements in AR training environments, advocating a nuanced approach to developing haptic feedback systems that complement AR technologies more effectively.
- Open Access
Physical determinants of perceived vibration intensity: Insights from haptic feedback at the wrist
Understanding how controlled mechanical vibrations applied to the skin translate into tactile sensations is key in advancing our understanding of somatosensory perception and using this in haptic applications. Prior research has established psychophysical thresholds and discrimination levels for vibrotactile stimuli, yet less is known about tactile intensity perception. Understanding the signaling of tactile intensity and how mechanical dynamics of skin transmission shape this is critical for providing effective graded haptic feedback. We investigated how modifying the frequency, amplitude, and waveform shape of vibration at the wrist influence free ratings of perceived tactile intensity. Two accelerometers recorded mechanical signals: one embedded within the vibrotactile wristband and another placed 1 cm away on the skin, enabling tracking of vibration propagation through the tissue. We found that perceived intensity was determined by all three parameters, but each had a distinct role. Vibration frequency exerted a non-linear influence, with perceived intensity peaking around 150 Hz, which also corresponded to the actuator’s mechanical resonance, with lower secondary peaks for square and sawtooth waveforms in-line with vibratory harmonics. Moreover, square waves were consistently rated as most intense. Vibration amplitude provided a consistent scaling of perceived strength, which was strongly correlated with both actuator and skin acceleration, indicating that skin-transmitted accelerations retained the stimulation profile. We find that the skin acts as a non-linear, frequency-dependent mechanical filter that selectively modulates vibration transmission. Understanding these determinants provides insights for the design of wearable haptic devices and how these can be used to provide graded feedback during tactile interactions.
Open AccessPhysical determinants of perceived vibration intensity: Insights from haptic feedback at the wrist
Understanding how controlled mechanical vibrations applied to the skin translate into tactile sensations is key in advancing our understanding of somatosensory perception and using this in haptic applications. Prior research has established psychophysical thresholds and discrimination levels for vibrotactile stimuli, yet less is known about tactile intensity perception. Understanding the signaling of tactile intensity and how mechanical dynamics of skin transmission shape this is critical for providing effective graded haptic feedback. We investigated how modifying the frequency, amplitude, and waveform shape of vibration at the wrist influence free ratings of perceived tactile intensity. Two accelerometers recorded mechanical signals: one embedded within the vibrotactile wristband and another placed 1 cm away on the skin, enabling tracking of vibration propagation through the tissue. We found that perceived intensity was determined by all three parameters, but each had a distinct role. Vibration frequency exerted a non-linear influence, with perceived intensity peaking around 150 Hz, which also corresponded to the actuator’s mechanical resonance, with lower secondary peaks for square and sawtooth waveforms in-line with vibratory harmonics. Moreover, square waves were consistently rated as most intense. Vibration amplitude provided a consistent scaling of perceived strength, which was strongly correlated with both actuator and skin acceleration, indicating that skin-transmitted accelerations retained the stimulation profile. We find that the skin acts as a non-linear, frequency-dependent mechanical filter that selectively modulates vibration transmission. Understanding these determinants provides insights for the design of wearable haptic devices and how these can be used to provide graded feedback during tactile interactions.