Wenbo Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Wenbo Li has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Shuaishuai Sun
University of Science and Technology of China
4 shared publications - Lei Deng
School of Electrical, Computer & Telecommunications Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
2 shared publications - Liang Zhang
Anhui University
2 shared publications - Shiwu Zhang
University of Science and Technology of China
2 shared publications - Weihua Li
School of Mechanical, Materials, Mechatronic and Biomedical Engineering, University of Wollongong, Wollongong, New South Wales 2522, Australia
2 shared publications - Xianlong Mai
Department of Excellence in Robotics and AI Institute of Mechanical Intelligence, Scuola Superiore Sant'Anna (SSSA) Pisa Italy
2 shared publications
Latest Publications
- 1 September 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (9) , 095008
Physics-guided modeling and semi-active control of magnetorheological actuators for quadruped locomotion
Magnetorheological actuators (MRAs) provide current-dependent resistance that can be used for load support and damping in legged robots, but their nonlinear, hysteretic, and history-dependent torque response makes them difficult to model and schedule during locomotion. This paper presents MRA-aware semi-active locomotion (MRA-SAL), a physics-guided modeling and control framework for MR_Go-SAL, a quadruped robot equipped with calf-joint MRAs. MRA-SAL separates the semi-active function of the MRA into current-regulated stance holding and velocity-opposing disturbance damping. A current-aware Bouc–Wen model with a PG-RLSTM residual term predicts the dynamic MRA torque, while a pre-yield current–torque fit estimates the holding capacity. The resulting model is embedded into the Isaac Gym low-level torque loop for actuator-aware policy training, while the MRA-SAL scheduler is deployed on hardware. The PG-RLSTM achieves the lowest prediction error, with an average RMSE of 0.355 Nm on ten unseen actuator trajectories. Current-sweep disturbance tests show consistent attenuation trends in simulation and hardware: as current increases from 0 to 1.5 A, the minimum CoM height increases by 14.7 % and 14.3 % , respectively, while the peak downward velocity magnitude decreases by 19.3 % and 35.4 % . Locomotion experiments show COT reductions of 20.2 – 25.4 % at 0.3 m s − 1 and 21.3 – 24.9 % at 0.5 m s − 1 relative to baseline MR_Go. Across three repeated 300 m field tasks, MR_Go-SAL reduces mean battery state-of-charge depletion from 59.3 ± 1.5 to 52.5 ± 2.0 percentage points relative to the matched MR_Go baseline. In the field-task thermal comparison, the mean temperature rise across the four calf motors decreases from 22.25 ∘ C for MR_Go to 11.50 ∘ C for MR_Go-SAL.
- 1 September 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (9) , 095008
Physics-guided modeling and semi-active control of magnetorheological actuators for quadruped locomotion
Magnetorheological actuators (MRAs) provide current-dependent resistance that can be used for load support and damping in legged robots, but their nonlinear, hysteretic, and history-dependent torque response makes them difficult to model and schedule during locomotion. This paper presents MRA-aware semi-active locomotion (MRA-SAL), a physics-guided modeling and control framework for MR_Go-SAL, a quadruped robot equipped with calf-joint MRAs. MRA-SAL separates the semi-active function of the MRA into current-regulated stance holding and velocity-opposing disturbance damping. A current-aware Bouc–Wen model with a PG-RLSTM residual term predicts the dynamic MRA torque, while a pre-yield current–torque fit estimates the holding capacity. The resulting model is embedded into the Isaac Gym low-level torque loop for actuator-aware policy training, while the MRA-SAL scheduler is deployed on hardware. The PG-RLSTM achieves the lowest prediction error, with an average RMSE of 0.355 Nm on ten unseen actuator trajectories. Current-sweep disturbance tests show consistent attenuation trends in simulation and hardware: as current increases from 0 to 1.5 A, the minimum CoM height increases by 14.7 % and 14.3 % , respectively, while the peak downward velocity magnitude decreases by 19.3 % and 35.4 % . Locomotion experiments show COT reductions of 20.2 – 25.4 % at 0.3 m s − 1 and 21.3 – 24.9 % at 0.5 m s − 1 relative to baseline MR_Go. Across three repeated 300 m field tasks, MR_Go-SAL reduces mean battery state-of-charge depletion from 59.3 ± 1.5 to 52.5 ± 2.0 percentage points relative to the matched MR_Go baseline. In the field-task thermal comparison, the mean temperature rise across the four calf motors decreases from 22.25 ∘ C for MR_Go to 11.50 ∘ C for MR_Go-SAL.
- 7 July 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (8) , 085003
Development of a Magnetorheological-Based Electrical Robotic Joint with characteristics of High Load Capability and High Energy Efficiency
With the rapid advancement of robotics in industrial, exploration, logistics, and domestic applications, actuator performance has become a critical factor in enabling robust and energy-efficient operation. While electric actuators offer compactness and precise control, they often suffer from limited load capacity and high energy consumption under sustained loads and impact conditions.To address these challenges, we propose a compact magnetorheological-enhanced joint that integrates electric actuation with magnetorheological (MR) damping. The proposed joint enables seamless switching between electric actuation and MR-based damping modes, exploiting the field-dependent rheological properties of magnetorheological fluid (MRF) to enhance impact mitigation and passive load-holding capability. Experimental characterization shows that the proposed MR actuator achieves a torque-to-mass ratio (TMR) of 174.3 Nm/kg and a torqueto-volume ratio (TVR) of 4.21 × 10 -4 Nm/mm 3 . When evaluated at the joint level, the system exhibits a TMR of 52.3 Nm/kg and a TVR of 8.4 × 10 -5 Nm/mm 3 . On a single-legged robotic testbed, the MR-enhanced joint reduces peak impact torque by 28% and peak vertical acceleration by 11.5% during free-fall landing compared to a purely electric baseline. In addition, quasi-static load tests demonstrate that the joint supports a 9 kg payload while consuming only 8 W, compared to 6 kg at 11.62 W for the baseline configuration. These results demonstrate that the proposed MR-enhanced joint provides improved impact robustness, increased load capacity, and reduced energy consumption within a compact and easily integrable actuator architecture.
- 7 July 2026
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 35 (8) , 085003
Development of a Magnetorheological-Based Electrical Robotic Joint with characteristics of High Load Capability and High Energy Efficiency
With the rapid advancement of robotics in industrial, exploration, logistics, and domestic applications, actuator performance has become a critical factor in enabling robust and energy-efficient operation. While electric actuators offer compactness and precise control, they often suffer from limited load capacity and high energy consumption under sustained loads and impact conditions.To address these challenges, we propose a compact magnetorheological-enhanced joint that integrates electric actuation with magnetorheological (MR) damping. The proposed joint enables seamless switching between electric actuation and MR-based damping modes, exploiting the field-dependent rheological properties of magnetorheological fluid (MRF) to enhance impact mitigation and passive load-holding capability. Experimental characterization shows that the proposed MR actuator achieves a torque-to-mass ratio (TMR) of 174.3 Nm/kg and a torqueto-volume ratio (TVR) of 4.21 × 10 -4 Nm/mm 3 . When evaluated at the joint level, the system exhibits a TMR of 52.3 Nm/kg and a TVR of 8.4 × 10 -5 Nm/mm 3 . On a single-legged robotic testbed, the MR-enhanced joint reduces peak impact torque by 28% and peak vertical acceleration by 11.5% during free-fall landing compared to a purely electric baseline. In addition, quasi-static load tests demonstrate that the joint supports a 9 kg payload while consuming only 8 W, compared to 6 kg at 11.62 W for the baseline configuration. These results demonstrate that the proposed MR-enhanced joint provides improved impact robustness, increased load capacity, and reduced energy consumption within a compact and easily integrable actuator architecture.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 2633-2644
Design and Validation of a Body-Powered Lower Extremity Exoskeleton Featuring Explosive Locomotion Augmentation
Exoskeletons, designed to enhance human strength and mobility, hold the potential to revolutionize fields such as rehabilitation, sports, industrial work, and defense. However, current designs are limited in augmenting explosive locomotion and reducing dependence on external energy sources. Given these challenges, we proposed a body-powered lower extremity exoskeleton employing clutched parallel elastic magnetorheological actuators (CPEMAs). The CPEMA on the knee joint primarily comprises a high-stiffness torsional spring to recycle the human body’s kinetic energy, three high-torque magnetorheological fluid bearings functioning as clutches, and a gear reducer for torque amplification. When the torsional springs are engaged, the CPEMAs accumulate energy from the knee’s periodic flexion and extension with low power consumption. Then, the stored energy can be released in one burst for explosive actuation. Theoretical analysis and experimental evaluation demonstrate the capabilities of the proposed exoskeleton, including enhancements of around 53% in kicking force, 31% in lower extremity strength, and 12% in jumping ability. The system advances the understanding of exoskeleton-assisted high-performance locomotion, showcasing a substantial potential to transcend the human body’s limitations.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 2633-2644
Design and Validation of a Body-Powered Lower Extremity Exoskeleton Featuring Explosive Locomotion Augmentation
Exoskeletons, designed to enhance human strength and mobility, hold the potential to revolutionize fields such as rehabilitation, sports, industrial work, and defense. However, current designs are limited in augmenting explosive locomotion and reducing dependence on external energy sources. Given these challenges, we proposed a body-powered lower extremity exoskeleton employing clutched parallel elastic magnetorheological actuators (CPEMAs). The CPEMA on the knee joint primarily comprises a high-stiffness torsional spring to recycle the human body’s kinetic energy, three high-torque magnetorheological fluid bearings functioning as clutches, and a gear reducer for torque amplification. When the torsional springs are engaged, the CPEMAs accumulate energy from the knee’s periodic flexion and extension with low power consumption. Then, the stored energy can be released in one burst for explosive actuation. Theoretical analysis and experimental evaluation demonstrate the capabilities of the proposed exoskeleton, including enhancements of around 53% in kicking force, 31% in lower extremity strength, and 12% in jumping ability. The system advances the understanding of exoskeleton-assisted high-performance locomotion, showcasing a substantial potential to transcend the human body’s limitations.
- 1 November 2025
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 34 (11) , 115028
Development of a magnetorheological hand exoskeleton featuring a high force-to-power ratio for enhanced grip endurance
Hand exoskeletons have significant potential in labor-intensive fields by mitigating hand grip fatigue, enhancing hand strength, and preventing injuries. However, most of the traditional hand exoskeletons are driven by motors, whose output force is limited in the constrained installation conditions. Besides, they also come with the disadvantages of high power consumption, complex and bulky assistive systems, and high instability. In this work, we develop a novel hand exoskeleton integrated with innovative magnetorheological (MR) clutches that offers a high force-to-power ratio to improve grip endurance. The clutch features an enhanced structure design, a micro roller enhancing structure, which can significantly boost output forces. The experimental data demonstrate that, when it is supplied with 2 V, the clutch can deliver a peak holding force of 381.15 N—55 times that when no voltage is provided (7 N). In this scenario, it only consumes 1.38 W, yielding a force-to-power ratio of 256.75 N W −1 , which is 2.35 times higher than the best-reported actuator used for hand exoskeletons. This capability enables the designed MR exoskeleton (MRHE) to provide approximately 419.79 N support force for gripping. The designed MR hand exoskeleton is highly integrated, comprising an exoskeleton frame, MR clutches, a control unit, and a battery. Evaluations through static grip endurance tests and dynamic carrying and lifting tests confirm that the MR hand exoskeleton can effectively reduce muscle fatigue, extend grip endurance, and minimize injuries. These findings highlight its strong potential for practical applications in repetitive tasks such as carrying and lifting in industrial settings.
- 1 November 2025
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 34 (11) , 115028
Development of a magnetorheological hand exoskeleton featuring a high force-to-power ratio for enhanced grip endurance
Hand exoskeletons have significant potential in labor-intensive fields by mitigating hand grip fatigue, enhancing hand strength, and preventing injuries. However, most of the traditional hand exoskeletons are driven by motors, whose output force is limited in the constrained installation conditions. Besides, they also come with the disadvantages of high power consumption, complex and bulky assistive systems, and high instability. In this work, we develop a novel hand exoskeleton integrated with innovative magnetorheological (MR) clutches that offers a high force-to-power ratio to improve grip endurance. The clutch features an enhanced structure design, a micro roller enhancing structure, which can significantly boost output forces. The experimental data demonstrate that, when it is supplied with 2 V, the clutch can deliver a peak holding force of 381.15 N—55 times that when no voltage is provided (7 N). In this scenario, it only consumes 1.38 W, yielding a force-to-power ratio of 256.75 N W −1 , which is 2.35 times higher than the best-reported actuator used for hand exoskeletons. This capability enables the designed MR exoskeleton (MRHE) to provide approximately 419.79 N support force for gripping. The designed MR hand exoskeleton is highly integrated, comprising an exoskeleton frame, MR clutches, a control unit, and a battery. Evaluations through static grip endurance tests and dynamic carrying and lifting tests confirm that the MR hand exoskeleton can effectively reduce muscle fatigue, extend grip endurance, and minimize injuries. These findings highlight its strong potential for practical applications in repetitive tasks such as carrying and lifting in industrial settings.