Borys Komarov
Research Subjects
Research Interests
Borys Komarov has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alla Reznik
Department of Physics, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
1 shared publication - Brandon Baldassi
Radialis Inc., Thunder Bay, ON P7A 7T1, Canada
1 shared publication - Harutyun Poladyan
Department of Physics, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
1 shared publication - Henry Maa-Hacquoil
Department of Physics, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
1 shared publication - Janos Rado
Department of Physics, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
1 shared publication - Oleksandr Bubon
Department of Physics, Lakehead University, Thunder Bay, ON P7B 5E1, Canada
1 shared publication
Latest Publications
- Open Access
Improved Edge Pixel Resolution in Modular PET Detectors with Partly Segmented Light Guides
Background: The asymmetric distribution of optical photons near the edges of Positron Emission Tomography (PET) sensor modules introduces errors in the coordinate reconstruction of scintillation events when center-of-gravity (CoG) algorithms are utilized. This issue, sometimes referred to as the “edge effect”, results in overlap of crystal pixel signatures in flood maps and potential image artifacts in reconstructed PET images. Methods: Partly segmented 5 mm thick borosilicate light guides with slits cut parallel to the edges are filled with barium sulfate to restrict the spread of optical photons near the edges of the light guide. Data acquisitions are performed using single PET sensor modules in coincidence, both with single and multiplexed channel readout. CoG and truncated center-of-gravity (TCoG) methods are used for coordinate reconstruction. Results: A 22 × 22 array of crystal signatures are distinguishable on crystal flood maps produced using sensor modules with solid light guides and 24 × 24 arrays can be identified when using a partly segmented light guide. The pixel resolution around the edges and corners of the flood map is further improved when TCoG is used for coordinate reconstruction. Summary: We show that the introduction of a partly segmented light guide greatly improves coordinate reconstruction accuracy at the edges of a sensor module. In addition, it is demonstrated that the partly segmented light guides can be used in parallel with other proposed methods designed to fix the “edge effect”, including TCoG, to further coordinate reconstruction improve accuracy and crystal flood map quality.
Open AccessImproved Edge Pixel Resolution in Modular PET Detectors with Partly Segmented Light Guides
Background: The asymmetric distribution of optical photons near the edges of Positron Emission Tomography (PET) sensor modules introduces errors in the coordinate reconstruction of scintillation events when center-of-gravity (CoG) algorithms are utilized. This issue, sometimes referred to as the “edge effect”, results in overlap of crystal pixel signatures in flood maps and potential image artifacts in reconstructed PET images. Methods: Partly segmented 5 mm thick borosilicate light guides with slits cut parallel to the edges are filled with barium sulfate to restrict the spread of optical photons near the edges of the light guide. Data acquisitions are performed using single PET sensor modules in coincidence, both with single and multiplexed channel readout. CoG and truncated center-of-gravity (TCoG) methods are used for coordinate reconstruction. Results: A 22 × 22 array of crystal signatures are distinguishable on crystal flood maps produced using sensor modules with solid light guides and 24 × 24 arrays can be identified when using a partly segmented light guide. The pixel resolution around the edges and corners of the flood map is further improved when TCoG is used for coordinate reconstruction. Summary: We show that the introduction of a partly segmented light guide greatly improves coordinate reconstruction accuracy at the edges of a sensor module. In addition, it is demonstrated that the partly segmented light guides can be used in parallel with other proposed methods designed to fix the “edge effect”, including TCoG, to further coordinate reconstruction improve accuracy and crystal flood map quality.