IPIosif Pagkalos

Iosif Pagkalos

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Iosif Pagkalos has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long-Term Clinical and Radiographic Osseointegration Outcomes of a Highly Porous 3D-Printed Titanium Collar Compared with a Hydroxyapatite-Coated Collar in Megaprostheses

    by Hariharan Triplicane Dwarakanathan, Natalie Green, Thomas Haider, Iosif Pagkalos, Guy Morris, Rajesh Botchu, Lee M. Jeys

    This is a retrospective, single-center cohort study comparing the long-term radiographic osseointegration and aseptic loosening between a 3D-printed EPORE® collar and a prior generation HA-coated collar in endoprosthetic reconstructions. Achieving stable bone integration in endoprosthetic reconstructions remains challenging, with hydroxyapatite (HA)-coated collars being the only option available in the past. Earlier studies from our center have shown reliable and accelerated osseointegration at the bone–collar interface using a novel highly porous 3D-printed EPORE® collar system compared to a previously used HA-coated collar. Methods: Twenty-eight patients who underwent an implantation of endoprostheses utilizing the novel 3D-printed EPORE® collar system were case-matched to 24 patients who had previously undergone surgeries using a HA-coated collar. The mean age at surgery was 65.2 years (range: 17–95 years). Patients in the HA-coated collar group had a mean age of 63.8 years (range: 17–86 years), while those in the 3D-printed collar group had a mean age of 66.7 years (range: 32–95 years), with no statistically significant difference between groups (p = 0.876). A minimum radiological and clinical follow-up of 2 years was available in all included cases. Osseointegration was evaluated using postoperative plain radiographs in two planes based on a previously validated semi-quantitative score. Results: When aseptic loosening was used as the primary endpoint, no failures occurred in the 3D-printed EPORE® group during the study period. The overall rate of stem loosening (including both aseptic and septic causes) was 7% (2/28) in the 3D-printed group and 16% (4/24) in the HA-coated group. All cases of loosening in the 3D-printed cohort were related to septic failure. This translates into a 2-year aseptic-loosening-free survival of 100% in the 3D-printed group. When the radiographic osseointegration was analyzed as the endpoint, the rate of successful osseointegration was significantly higher in the 3D-printed group (92.9%, 26/28; 95% CI 76.5–99.1%) compared with the HA-coated group (70.8%, 17/24; 95% CI 48.9–87.4%; p = 0.04). The distribution of ongrowth scores also differed significantly between groups. The highest ongrowth score (grade 4) was achieved in 82.14% of 3D-printed implants (23/28; 95% CI 63.1–93.9%), compared with 37.5% of HA-coated implants (9/24; p = 0.0002). The time to achieve grade 4 ongrowth was significantly shorter in the 3D-printed cohort, with a median of 470 days (IQR 360–610), compared with 1482 days (IQR 1020–1860) in the HA-coated group (p < 0.0001). In addition, patients in the 3D-printed implant group had a significantly higher mean body mass index compared with the HA-coated group (32.51 vs. 28.36, p = 0.01). Conclusions: These results show that the novel highly porous 3D-printed EPORE® collars reduce aseptic loosening and accelerate extracortical bridging in endoprosthetic replacements. This benefit persisted even in higher BMI or revision contexts when compared to the previously used HA-coated collars.


  • Open Access

    Long Term Clinical and Radiographic Osseointegration Outcomes of a Highly Porous 3D Printed Titanium Collar for Megaprostheses Compared to a Previous Generation Ha Coated Collar

    by Hariharan Triplicane Dwarakanathan, Natalie Green, Thomas Haider, Iosif Pagkalos, Guy Morris, Rajesh Botchu, Lee M Jeys

    Achieving stable bone integration in megaprosthetic reconstructions remains challenging, with traditional hydroxyapatite (HA)-coated collars showing variable outcomes. This study compares long-term osseointegration and clinical performance of a novel 3D-printed porous collar (EPORE®) versus conventional HA-coated collars in 52 patients (28 with 3D-printed, 24 with HA-coated). Radiographic osseointegration was assessed using a validated scoring system, with follow-up exceeding two years. The 3D-printed group demonstrated significantly higher osseointegration rates (92.9% vs. 70.8%, p=0.04) and faster bone ongrowth (470 vs. 1482 days to full integration, p<0.0001), with 89.3% achieving the highest integration score compared to 37.5% in the HA group (p=0.0002). Notably, no aseptic loosening occurred with 3D-printed collars, while HA-coated collars had an 8% aseptic loosening rate. Despite higher BMI in the 3D-printed group (32.5 vs. 28.4, p=0.01), outcomes were superior, suggesting the porous design mitigates obesity-related risks. These findings indicate that 3D-printed collars enhance biological fixation, reduce loosening, and improve implant stability, particularly in complex revisions. This technology represents a significant advancement in megaprosthetic design, with potential to improve long-term outcomes in high-risk patients.