Oriol Fernández-Serracanta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Oriol Fernández-Serracanta has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Min Zhang
University of Strathclyde
5 shared publications - Alexander Shchukin
University of Strathclyde, Glasgow, U.K.
3 shared publications - Jin Zhang
Queen Mary University of London
3 shared publications - Weijia Yuan
University of Strathclyde
3 shared publications - Ivan V. Konoplev
The John Adams Institute, Department of Physics, University of Oxford, Oxford OX1 3RH, United Kingdom
2 shared publications - Rui Li
University of Strathclyde
2 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (11) , 115003
Digital compensation framework for transport AC loss measurements in multistack superconducting coils
High-temperature superconducting (HTS) coils are used in high-current, high-field applications such as fusion magnets and electric aviation. In many designs, several tapes or stacks are connected within each turn to increase current capacity while maintaining low operating voltage. However, these multistack configurations can develop non-uniform current distributions, which affect alternating current (AC) losses and complicate their experimental characterisation. This work presents and evaluates a digital compensation framework for transport AC loss measurements in multi-stack HTS coils. The proposed framework is formulated as a common post-processing procedure in which three elements can vary: the inductive reference signal, its representation during compensation, and the fitting region used to estimate the compensation coefficient. Two global reference strategies are investigated under the same experimental conditions: a Rogowski-based reference and a secondary-coil reference obtained from a dedicated primary-secondary compensation circuit. For each, both full-waveform and phase-guided compensation approaches are assessed. The framework is evaluated across a hierarchy of coil topologies, including single-tape, single-stack, balanced double-stack, and unbalanced double-stack coils. The results show that the secondary-coil full-waveform implementation provides the most robust performance and is recommended as the preferred default when available. In contrast, Rogowski-based compensation is more sensitive to coil topology, frequency, sensor placement, and current redistribution. Full-waveform compensation generally gives the closest agreement with manual compensation, whereas secondary phase-guided compensation often remains close to the corresponding full-waveform implementation despite using reduced reference information. It therefore provides a useful reduced-information alternative when the reference phase is stable. A fitting-window sensitivity study shows that window location is more critical than window size, with the best performance obtained for low-current windows placed near, but slightly shifted from, the current zero crossing. Overall, the proposed framework provides a practical method-selection and qualification route for AC loss characterisation in complex HTS windings and clarifies when simplified reference representations remain valid.
- 1 November 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (11) , 115003
Open AccessDigital compensation framework for transport AC loss measurements in multistack superconducting coils
High-temperature superconducting (HTS) coils are used in high-current, high-field applications such as fusion magnets and electric aviation. In many designs, several tapes or stacks are connected within each turn to increase current capacity while maintaining low operating voltage. However, these multistack configurations can develop non-uniform current distributions, which affect alternating current (AC) losses and complicate their experimental characterisation. This work presents and evaluates a digital compensation framework for transport AC loss measurements in multi-stack HTS coils. The proposed framework is formulated as a common post-processing procedure in which three elements can vary: the inductive reference signal, its representation during compensation, and the fitting region used to estimate the compensation coefficient. Two global reference strategies are investigated under the same experimental conditions: a Rogowski-based reference and a secondary-coil reference obtained from a dedicated primary-secondary compensation circuit. For each, both full-waveform and phase-guided compensation approaches are assessed. The framework is evaluated across a hierarchy of coil topologies, including single-tape, single-stack, balanced double-stack, and unbalanced double-stack coils. The results show that the secondary-coil full-waveform implementation provides the most robust performance and is recommended as the preferred default when available. In contrast, Rogowski-based compensation is more sensitive to coil topology, frequency, sensor placement, and current redistribution. Full-waveform compensation generally gives the closest agreement with manual compensation, whereas secondary phase-guided compensation often remains close to the corresponding full-waveform implementation despite using reduced reference information. It therefore provides a useful reduced-information alternative when the reference phase is stable. A fitting-window sensitivity study shows that window location is more critical than window size, with the best performance obtained for low-current windows placed near, but slightly shifted from, the current zero crossing. Overall, the proposed framework provides a practical method-selection and qualification route for AC loss characterisation in complex HTS windings and clarifies when simplified reference representations remain valid.
- Open Access
- 21 October 2026
- Published by IOP Publishing in Superconductor Science and Technology
Analysis of AC losses and current distribution in parallel-wound HTS coils for superconducting motor armature windings
High temperature superconducting (HTS) coils composed of parallel conductors are being widely investigated to enhance the critical current in superconducting applications. Most studies on parallel-conductor wound coils focus on no-insulation coils under DC conditions, particularly their charging and discharging behaviour. In contrast, the parallel-wound coil considered in this work targets AC applications, such as armature windings in superconducting machines, for which the current distribution and AC loss characteristics remain insufficiently understood. Meanwhile, due to the electrical coupling at the HTS conductor terminals, the current distribution becomes a key issue, which is essential for evaluating the current-carrying capacity and quench limits of the coil. Due to the limited research on this type of coil for AC applications, three numerical methods were first employed to validate the accuracy of the model calculations, namely the weak form T-A formulation with Neumann boundary conditions, the T-A formulation with electrical circuit, and the H formulation, respectively. The three methods show strong agreement. Subsequently, the current distribution and AC losses of inductance-imbalanced and inductance-balanced coils were systematically compared under different excitation conditions. It is found that inductance imbalance induces circulating currents between parallel stacks, resulting in asymmetric current distribution, enhanced AC losses, and increased risk of local overcurrent, particularly under time-varying magnetic fields. In contrast, the inductance-balanced coil maintains more stable electromagnetic behaviour, where both the current distribution and AC losses exhibit weak sensitivity to variations in the externally applied parallel magnetic field. We also compared the current distribution and AC losses of coils with different numbers of parallel conductors under different excitation conditions and clarified the effects of transport current and applied magnetic field on the losses. These findings demonstrate the importance of inductance balancing for the reliable and safe operation of HTS AC power devices.
- 21 October 2026
- Published by IOP Publishing in Superconductor Science and Technology
Open AccessAnalysis of AC losses and current distribution in parallel-wound HTS coils for superconducting motor armature windings
High temperature superconducting (HTS) coils composed of parallel conductors are being widely investigated to enhance the critical current in superconducting applications. Most studies on parallel-conductor wound coils focus on no-insulation coils under DC conditions, particularly their charging and discharging behaviour. In contrast, the parallel-wound coil considered in this work targets AC applications, such as armature windings in superconducting machines, for which the current distribution and AC loss characteristics remain insufficiently understood. Meanwhile, due to the electrical coupling at the HTS conductor terminals, the current distribution becomes a key issue, which is essential for evaluating the current-carrying capacity and quench limits of the coil. Due to the limited research on this type of coil for AC applications, three numerical methods were first employed to validate the accuracy of the model calculations, namely the weak form T-A formulation with Neumann boundary conditions, the T-A formulation with electrical circuit, and the H formulation, respectively. The three methods show strong agreement. Subsequently, the current distribution and AC losses of inductance-imbalanced and inductance-balanced coils were systematically compared under different excitation conditions. It is found that inductance imbalance induces circulating currents between parallel stacks, resulting in asymmetric current distribution, enhanced AC losses, and increased risk of local overcurrent, particularly under time-varying magnetic fields. In contrast, the inductance-balanced coil maintains more stable electromagnetic behaviour, where both the current distribution and AC losses exhibit weak sensitivity to variations in the externally applied parallel magnetic field. We also compared the current distribution and AC losses of coils with different numbers of parallel conductors under different excitation conditions and clarified the effects of transport current and applied magnetic field on the losses. These findings demonstrate the importance of inductance balancing for the reliable and safe operation of HTS AC power devices.
- 13 November 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (5)
Fast quench detection via coolant-gas-temperature monitoring of a high-temperature superconducting magnet
- 13 November 2025
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 24 (5)
Fast quench detection via coolant-gas-temperature monitoring of a high-temperature superconducting magnet
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-4
AC Loss of Parallel-wound HTS Coils Designed for the Armature Coil of Aviation Propulsion Motor
Aviation electric propulsion requires reliable, high-current, low-loss armature windings with low mass to achieve high motor power density. A new approach using parallel-stacked superconducting tapes in wet windings has been proposed to meet these requirements. The coil was designed and tested in liquid nitrogen. This paper focuses on the AC loss characterization of the HTS coil by comparing experimental and simulation results. Instead of employing a coupled circuit model with uncertain resistivity values, directly using the experimentally measured current distribution provides a faster solution with good agreement to the experimental results. The method can be used to predict AC losses at higher currents.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-4
AC Loss of Parallel-wound HTS Coils Designed for the Armature Coil of Aviation Propulsion Motor
Aviation electric propulsion requires reliable, high-current, low-loss armature windings with low mass to achieve high motor power density. A new approach using parallel-stacked superconducting tapes in wet windings has been proposed to meet these requirements. The coil was designed and tested in liquid nitrogen. This paper focuses on the AC loss characterization of the HTS coil by comparing experimental and simulation results. Instead of employing a coupled circuit model with uncertain resistivity values, directly using the experimentally measured current distribution provides a faster solution with good agreement to the experimental results. The method can be used to predict AC losses at higher currents.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Gas Properties Studies Using Reflectometry: First Steps Towards Real Time Cooling Gas Temperature Monitoring in Superconducting Magnets
To carry out fast (real time) temperature monitoring of the coolant gas and thus to observe evolution and enable the prevention of the quenching in superconducting (SC) magnets the frequency and time domain reflectometry (FTDR) i.e., analysis of microwave electromagnetic signals propagating in coolant gas channels, have been recently proposed. Here the results of numerical and experimental studies of fundamentals of the application of the microwave (RF) FTDR for quench monitoring are discussed. Through the studies, we show that variations of external conditions induce change in the gas permittivity, which can be measured fast and accurately. The methodology presented is based on correlations between thermodynamic gas variables (temperature and pressure) with its electromagnetic properties (refractive index). The sensitivity to both temperature and pressure suggests that the technique allow monitoring other anomalies i.e., not only temperature, including the gas pressure, the flow rate variations and turbulence. Through the numerical studies it was found that a localised hotspot can be detected with minimal time delay, which is crucial consideration for quench prevention and magnet “health” monitoring. The experimental data observed agree well with the theoretical understandings, and the preliminary findings promote further investigations in cryogenic environment of the proposed technique.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (3) , 1-5
Gas Properties Studies Using Reflectometry: First Steps Towards Real Time Cooling Gas Temperature Monitoring in Superconducting Magnets
To carry out fast (real time) temperature monitoring of the coolant gas and thus to observe evolution and enable the prevention of the quenching in superconducting (SC) magnets the frequency and time domain reflectometry (FTDR) i.e., analysis of microwave electromagnetic signals propagating in coolant gas channels, have been recently proposed. Here the results of numerical and experimental studies of fundamentals of the application of the microwave (RF) FTDR for quench monitoring are discussed. Through the studies, we show that variations of external conditions induce change in the gas permittivity, which can be measured fast and accurately. The methodology presented is based on correlations between thermodynamic gas variables (temperature and pressure) with its electromagnetic properties (refractive index). The sensitivity to both temperature and pressure suggests that the technique allow monitoring other anomalies i.e., not only temperature, including the gas pressure, the flow rate variations and turbulence. Through the numerical studies it was found that a localised hotspot can be detected with minimal time delay, which is crucial consideration for quench prevention and magnet “health” monitoring. The experimental data observed agree well with the theoretical understandings, and the preliminary findings promote further investigations in cryogenic environment of the proposed technique.