Shihui Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shihui Wei has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Feng Qiu
Institute of Modern Physics
3 shared publications - Yilin Miao
Institute of Modern Physics
3 shared publications Zhaojie Chen
Institute of Modern Physics
3 shared publicationsChengye Xu
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
2 shared publications- Jinying Ma
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
2 shared publications Liepeng Sun
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
2 shared publications
Latest Publications
- Open Access
- 29 June 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (6)
Online beam phase and current calibration for rf cavities under closed-loop operation
Leveraging the interaction between the beam and the radio-frequency (rf) cavity to measure the beam phase reduces tuning time and mitigates slow drifts induced by ambient conditions. An online phase-measurement approach based on beam-induced rf transients was previously demonstrated at DESY using superconducting rf cavities in an electron accelerator under open-loop operation. However, open-loop operation is unsuitable for high-current proton or heavy-ion linacs due to elevated risks of beam loss and trips. This work proposes two novel schemes that operate under closed-loop conditions. The first, a virtual open-loop (VOL) method, solves the cavity difference equation to remove the contribution of feedback (and/or feedforward) control from the cavity field, thereby recovering the beam-loading signal under an equivalent open-loop condition from which the beam parameters are determined. The second, a steady-state (SS) method, determines the beam parameters (i.e., beam current and phase) when beam-loading and cavity-detuning compensation are sufficient and infers the beam phase and current by computing the vector difference of steady-state forward voltages with and without beam. Both approaches were systematically validated on the buncher cavity at the European Spallation Source (ESS), showing agreement with independent beam diagnostics, with phase error within ± 0.5 ° and current error within ± 4 % . The methods enable real-time, accurate beam-phase measurement during closed-loop operation and are readily extensible to other high-power accelerator systems.
- 29 June 2026
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 29 (6)
Open AccessOnline beam phase and current calibration for rf cavities under closed-loop operation
Leveraging the interaction between the beam and the radio-frequency (rf) cavity to measure the beam phase reduces tuning time and mitigates slow drifts induced by ambient conditions. An online phase-measurement approach based on beam-induced rf transients was previously demonstrated at DESY using superconducting rf cavities in an electron accelerator under open-loop operation. However, open-loop operation is unsuitable for high-current proton or heavy-ion linacs due to elevated risks of beam loss and trips. This work proposes two novel schemes that operate under closed-loop conditions. The first, a virtual open-loop (VOL) method, solves the cavity difference equation to remove the contribution of feedback (and/or feedforward) control from the cavity field, thereby recovering the beam-loading signal under an equivalent open-loop condition from which the beam parameters are determined. The second, a steady-state (SS) method, determines the beam parameters (i.e., beam current and phase) when beam-loading and cavity-detuning compensation are sufficient and infers the beam phase and current by computing the vector difference of steady-state forward voltages with and without beam. Both approaches were systematically validated on the buncher cavity at the European Spallation Source (ESS), showing agreement with independent beam diagnostics, with phase error within ± 0.5 ° and current error within ± 4 % . The methods enable real-time, accurate beam-phase measurement during closed-loop operation and are readily extensible to other high-power accelerator systems.
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (5) , 1830-1840
Automated PI Parameter Optimization for LLRF Systems: A Comparative Study of LLM-Guided Parameter Tuning and Bayesian Optimization Approaches
This paper presents a comparative study of LLM-guided parameter tuning and Bayesian Optimization (BO) for automated PI parameter adjustment in Low Level Radio Frequency (LLRF) systems. Both methods demonstrate effective performance across continuous wave and pulsed operation modes, addressing the challenges of traditional manual tuning in superconducting accelerator facilities. Multi-cavity validation experiments were conducted on both operation modes. For continuous wave 2-parameter optimization, both methods converge to optimal regions within 15 iterations. For pulsed 6-parameter optimization involving coupled amplitude-phase control loops, both methods achieve satisfactory results in around 20 iterations, meeting stability requirements for beam operation. Comparative analysis reveals distinct application advantages: BO is better suited for large-scale batch optimization scenarios, particularly excelling in multi-cavity parallel commissioning and high-dimensional parameter space exploration due to its systematic probabilistic framework. The LLM-guided approach is more appropriate for online optimization scenarios with strict operational constraints, where its conservative optimization strategy and traceable reasoning process make it ideal for parameter fine-tuning during operations. The study provides practical method selection guidelines for intelligent operation of large-scale accelerator facilities.
- 30 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 73 (5) , 1830-1840
Automated PI Parameter Optimization for LLRF Systems: A Comparative Study of LLM-Guided Parameter Tuning and Bayesian Optimization Approaches
This paper presents a comparative study of LLM-guided parameter tuning and Bayesian Optimization (BO) for automated PI parameter adjustment in Low Level Radio Frequency (LLRF) systems. Both methods demonstrate effective performance across continuous wave and pulsed operation modes, addressing the challenges of traditional manual tuning in superconducting accelerator facilities. Multi-cavity validation experiments were conducted on both operation modes. For continuous wave 2-parameter optimization, both methods converge to optimal regions within 15 iterations. For pulsed 6-parameter optimization involving coupled amplitude-phase control loops, both methods achieve satisfactory results in around 20 iterations, meeting stability requirements for beam operation. Comparative analysis reveals distinct application advantages: BO is better suited for large-scale batch optimization scenarios, particularly excelling in multi-cavity parallel commissioning and high-dimensional parameter space exploration due to its systematic probabilistic framework. The LLM-guided approach is more appropriate for online optimization scenarios with strict operational constraints, where its conservative optimization strategy and traceable reasoning process make it ideal for parameter fine-tuning during operations. The study provides practical method selection guidelines for intelligent operation of large-scale accelerator facilities.
- Open Access
- 13 November 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (11)
Analytical modeling and experimental verification of oscillatory ponderomotive instabilities in closed-loop superconducting rf cavities
Superconducting radio-frequency (SRF) cavities with high-loaded-Q are susceptible to ponderomotive instabilities arising from nonlinear electromechanical coupling. Under low-level rf feedback control, stability analysis is challenging and has, until now, lacked comprehensive experimental verification. In this work, we linearize the coupled cavity electromagnetic and mechanical equations about the operating point, deriving explicit small-signal stability criteria for both open- and closed-loop operation. A characteristic equation approach is used to map the oscillatory instability threshold in the detuning–gradient plane. Time-domain simulations confirm the predicted onset of self-excited oscillations at these thresholds. Furthermore, experiments on a 162.5 MHz SRF linac (CAFE2) show that the observed oscillation onset agrees with our analytical predictions within a small margin. By combining analytical modeling, numerical simulation, and direct experimentation, this study providescomprehensive validation of oscillatory ponderomotive instability theory under feedback control, offering practical guidance for the stable operation of high-gradient SRF accelerators.
- 13 November 2025
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 28 (11)
Open AccessAnalytical modeling and experimental verification of oscillatory ponderomotive instabilities in closed-loop superconducting rf cavities
Superconducting radio-frequency (SRF) cavities with high-loaded-Q are susceptible to ponderomotive instabilities arising from nonlinear electromechanical coupling. Under low-level rf feedback control, stability analysis is challenging and has, until now, lacked comprehensive experimental verification. In this work, we linearize the coupled cavity electromagnetic and mechanical equations about the operating point, deriving explicit small-signal stability criteria for both open- and closed-loop operation. A characteristic equation approach is used to map the oscillatory instability threshold in the detuning–gradient plane. Time-domain simulations confirm the predicted onset of self-excited oscillations at these thresholds. Furthermore, experiments on a 162.5 MHz SRF linac (CAFE2) show that the observed oscillation onset agrees with our analytical predictions within a small margin. By combining analytical modeling, numerical simulation, and direct experimentation, this study providescomprehensive validation of oscillatory ponderomotive instability theory under feedback control, offering practical guidance for the stable operation of high-gradient SRF accelerators.