Li Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Li Chen has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Guangwei Chen
Key Laboratory of Modern Optoelectronic Measurement Technology in Mechanical Industry, Beijing Information Science and Technology University, Beijing 100192, China
2 shared publications Ji Bo Han
Changcheng Institute of Metrology & Measurement
1 shared publication- Jibo Han
Changcheng Institute of Metrology and Measurement, Beijing, China
1 shared publication Peng Yu Yan
1 shared publicationShiyu Yang Yang
1 shared publicationTeng Fei Wu
Changcheng Institute of Metrology & Measurement
1 shared publication
Latest Publications
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-14
Time-Stretched Optical Frequency Comb Dispersive Fourier Transformation for Rapid Measurement of 3-D Morphology of Solar Cells
Accurate measurement and quality inspection of solar cell morphology are essential for ensuring high fabrication yield and device performance. Conventional techniques for online inspection are restricted by slow acquisition speed, limited resolution, or complex implementation, and thus cannot fully satisfy the demands of high-throughput manufacturing. To overcome these limitations, we propose a spectral interference measurement method based on an optical frequency comb (OFC) combined with time-stretched dispersive Fourier transform (TS-DFT), enabling real-time, continuous, and high-speed analysis. Theoretical analysis indicates that the minimum detection time per frame can reach 4 ns owing to the repetition rate of the OFC, whereas the practical acquisition speed in the current implementation is limited to the millisecond scale due to hardware constraints. Experimental results demonstrate a spectral resolution of 0.39 nm and high accuracy with root-mean-square errors of 0.543 μm (locked OFC) and 0.732 μm (unlocked OFC). These results confirm the capability of the proposed system for precise online inspection and its potential in 3D precision manufacturing.
- 13 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-14
Time-Stretched Optical Frequency Comb Dispersive Fourier Transformation for Rapid Measurement of 3-D Morphology of Solar Cells
Accurate measurement and quality inspection of solar cell morphology are essential for ensuring high fabrication yield and device performance. Conventional techniques for online inspection are restricted by slow acquisition speed, limited resolution, or complex implementation, and thus cannot fully satisfy the demands of high-throughput manufacturing. To overcome these limitations, we propose a spectral interference measurement method based on an optical frequency comb (OFC) combined with time-stretched dispersive Fourier transform (TS-DFT), enabling real-time, continuous, and high-speed analysis. Theoretical analysis indicates that the minimum detection time per frame can reach 4 ns owing to the repetition rate of the OFC, whereas the practical acquisition speed in the current implementation is limited to the millisecond scale due to hardware constraints. Experimental results demonstrate a spectral resolution of 0.39 nm and high accuracy with root-mean-square errors of 0.543 μm (locked OFC) and 0.732 μm (unlocked OFC). These results confirm the capability of the proposed system for precise online inspection and its potential in 3D precision manufacturing.
- 19 November 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (24) , 50407-50421
Deep learning-driven recovery of oversaturated interferometric signals for continuous 3D morphology measurement of complex surfaces in OFC-TS-DFT systems
To address signal oversaturation caused by the limited dynamic range of photodetectors in optical frequency comb (OFC) time-stretch spectral interferometry, we design a Uformer 1D network that integrates U-Net and Transformer architectures for signal recovery. The model is trained via a three-stage strategy: large-scale ideal-simulation pretraining, real paired-data fine-tuning with frequency-domain and total variation losses, and self-supervised learning on unlabeled real signals to enhance generalization. Experiments show that the recovered signals achieve a mean measurement error of ∼0.2 µm, with final average log-RMSEs of 0.065 (training) and 0.057 (validation), extending the effective dynamic range from 10 dBm to 15 dBm. Real-time surface reconstruction of a one-yuan coin further demonstrates its potential for continuous, real-time, high-dynamic-range 3D morphology measurement.
- 19 November 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (24) , 50407-50421
Deep learning-driven recovery of oversaturated interferometric signals for continuous 3D morphology measurement of complex surfaces in OFC-TS-DFT systems
To address signal oversaturation caused by the limited dynamic range of photodetectors in optical frequency comb (OFC) time-stretch spectral interferometry, we design a Uformer 1D network that integrates U-Net and Transformer architectures for signal recovery. The model is trained via a three-stage strategy: large-scale ideal-simulation pretraining, real paired-data fine-tuning with frequency-domain and total variation losses, and self-supervised learning on unlabeled real signals to enhance generalization. Experiments show that the recovered signals achieve a mean measurement error of ∼0.2 µm, with final average log-RMSEs of 0.065 (training) and 0.057 (validation), extending the effective dynamic range from 10 dBm to 15 dBm. Real-time surface reconstruction of a one-yuan coin further demonstrates its potential for continuous, real-time, high-dynamic-range 3D morphology measurement.