Elisabet Maristany Bosch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elisabet Maristany Bosch has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Edward John Despott
Royal Free Unit for Endoscopy The Royal Free Hospital and University College London (UCL) Institute for Liver and Digestive Health London UK
5 shared publications Alberto Murino
Royal Free Hospital, United Kingdom of Great Britain and Northern Ireland
4 shared publicationsGeorgios Kalopitas
Royal Free Hospital, United Kingdom of Great Britain and Northern Ireland
4 shared publicationsHironori Yamamoto
Endoscopy Center Jichi Medical University Hospital Shimotsuke Japan
2 shared publications- Hironori Yamamoto
Jichi Medical University, Tochigi Prefecture, Japan
2 shared publications - Alberto Murino
Royal Free Hospital, London, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 28 September 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 05) , E1053-E1054
Endoscopic full-thickness resection of a colonic granular cell tumour using a full-thickness resection device system
- 28 September 2026
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 58 (S 05) , E1053-E1054
Open AccessEndoscopic full-thickness resection of a colonic granular cell tumour using a full-thickness resection device system
- Open Access
- 3 December 2025
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 41 (1) , 268-277
The Saline‐Immersion/Irrigation TEchnique for Endoscopic Submucosal Dissection of Colorectal Lesions: Outcomes From a Large Western Cohort
Background and Study Aims: Endoscopic submucosal dissection (ESD) is increasingly used for the resection of complex lesions of the gastrointestinal tract. However, its adoption in the management of colonic lesions in Western practice remains challenging, mainly due to the anatomical complexities of the colon. The saline‐immersion/irrigation technique (SITE), combined with the pocket‐creation method (PCM) may help to overcome these challenges. This study evaluates outcomes of SITE‐PCM ESD in a Western tertiary center. Methods: We analyzed consecutive colorectal ESD procedures performed at our center between 2017 and 2024. SITE‐PCM was used in all cases. Lesion characteristics, procedural outcomes, histopathological findings, adverse events, and follow‐up data were analyzed. Results: A total of 181 lesions in 177 patients were resected en bloc using SITE‐PCM ESD. Sixty lesions (33.1%) were located in the proximal colon, while 79 (43.6%) were rectal lesions. R0 and curative resection rates were 92.3% and 90.6%, respectively. The median procedure time was 120 min. Adverse events occurred in 4.4% of cases, with only three patients necessitating hospitalization and nonsurgical intervention due to delayed bleeding, and one patient requiring surgical management after a delayed perforation. Notably, 93.4% of the procedures were performed under conscious sedation. Conclusions: In our experience SITE‐PCM‐ESD appears to be a safe and effective minimally invasive approach for complex colorectal lesions. It achieves high R0 and curative resection rates with low adverse events and is feasible under conscious sedation. These findings support broader adoption of SITE‐PCM in Western practice and justify prospective multicenter validation.
- 3 December 2025
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 41 (1) , 268-277
Open AccessThe Saline‐Immersion/Irrigation TEchnique for Endoscopic Submucosal Dissection of Colorectal Lesions: Outcomes From a Large Western Cohort
Background and Study Aims: Endoscopic submucosal dissection (ESD) is increasingly used for the resection of complex lesions of the gastrointestinal tract. However, its adoption in the management of colonic lesions in Western practice remains challenging, mainly due to the anatomical complexities of the colon. The saline‐immersion/irrigation technique (SITE), combined with the pocket‐creation method (PCM) may help to overcome these challenges. This study evaluates outcomes of SITE‐PCM ESD in a Western tertiary center. Methods: We analyzed consecutive colorectal ESD procedures performed at our center between 2017 and 2024. SITE‐PCM was used in all cases. Lesion characteristics, procedural outcomes, histopathological findings, adverse events, and follow‐up data were analyzed. Results: A total of 181 lesions in 177 patients were resected en bloc using SITE‐PCM ESD. Sixty lesions (33.1%) were located in the proximal colon, while 79 (43.6%) were rectal lesions. R0 and curative resection rates were 92.3% and 90.6%, respectively. The median procedure time was 120 min. Adverse events occurred in 4.4% of cases, with only three patients necessitating hospitalization and nonsurgical intervention due to delayed bleeding, and one patient requiring surgical management after a delayed perforation. Notably, 93.4% of the procedures were performed under conscious sedation. Conclusions: In our experience SITE‐PCM‐ESD appears to be a safe and effective minimally invasive approach for complex colorectal lesions. It achieves high R0 and curative resection rates with low adverse events and is feasible under conscious sedation. These findings support broader adoption of SITE‐PCM in Western practice and justify prospective multicenter validation.