Charalampos Zacharopoulos
Charalampos Zacharopoulos has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ilia N. Ivanov
Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, Oak Ridge, TN 37831-6496, USA
1 shared publication - Kiran Sontakke
Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynska dolina F1, 84248 Bratislava, Slovakia
1 shared publication - Leda G. Bousiakou
IMD Laboratories Co., R&D Section, Lefkippos Technology Park, NCSR Demokritos, P.O. Box 60037, 15130 Athens, Greece
1 shared publication - Maria Pavai
Institute of Materials and Environmental Chemistry, HUN-REN Research Centre for Natural Sciences, Magyar tudósok krt. 2, 1117 Budapest, Hungary
1 shared publication - Minas Kakos
IMD Laboratories Co., R&D Section, Lefkippos Technology Park, NCSR Demokritos, 15341 Agia Paraskevi, Greece
1 shared publication - Tibor Hianik
Faculty of Mathematics, Physics and Informatics, Comenius University, Mlynska dolina F1, 842 48 Bratislava, Slovakia
1 shared publication
Latest Publications
- Open Access
- 21 November 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 106 (1) , 16
Application of the Reduced Graphene Oxide–Multiwalled Carbon Nanotubes Composite for Development of the Electrochemical Aptasensor for Oxytetracycline Detection
Excessive use of oxytetracycline (OTC) in veterinary medicine has increased the presence of antibiotics in food, which accelerates the development of antimicrobial resistance. We report the development of a highly sensitive electrochemical aptasensor for OTC detection, based on a glassy carbon electrode (GCE) modified with reduced graphene oxide (rGO) and multiwalled carbon nanotubes (MWCNTs) nanocomposite. DNA aptamers specific to OTC were covalently attached to the nanocomposite surface via carbodiimide chemistry. Differential pulse voltammetry (DPV) showed a decrease in peak current due to the binding of OTC to the aptamers. The sensor exhibited a limit of detection (LOD) of 1.72 ng/mL, which is below the maximum residue limit (MRL) for OTC (100 ng/mL) established by European Union. The sensor has been tested on a spiked milk sample.
- 21 November 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 106 (1) , 16
Open AccessApplication of the Reduced Graphene Oxide–Multiwalled Carbon Nanotubes Composite for Development of the Electrochemical Aptasensor for Oxytetracycline Detection
Excessive use of oxytetracycline (OTC) in veterinary medicine has increased the presence of antibiotics in food, which accelerates the development of antimicrobial resistance. We report the development of a highly sensitive electrochemical aptasensor for OTC detection, based on a glassy carbon electrode (GCE) modified with reduced graphene oxide (rGO) and multiwalled carbon nanotubes (MWCNTs) nanocomposite. DNA aptamers specific to OTC were covalently attached to the nanocomposite surface via carbodiimide chemistry. Differential pulse voltammetry (DPV) showed a decrease in peak current due to the binding of OTC to the aptamers. The sensor exhibited a limit of detection (LOD) of 1.72 ng/mL, which is below the maximum residue limit (MRL) for OTC (100 ng/mL) established by European Union. The sensor has been tested on a spiked milk sample.