Dominik Przepiórka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dominik Przepiórka has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Paweł Pijarski
Department of Power Engineering, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, Nadbystrzycka 38D, 20-618 Lublin, Poland
4 shared publications - Adrian Belowski
Department of Power Engineering, Lublin University of Technology, 20-618 Lublin, Poland
2 shared publications - Damir Jakus
Faculty of Electrical Engineering, Mechanical Engineering and Naval Architecture, University of Split, Ruđera Boškovića 32, 21000 Split, Croatia
2 shared publications - Jarosław Wiśniowski
Department of Power Electronics and Power Engineering, Rzeszów University of Technology, al. Powstańców Warszawy 12, 35-029 Rzeszów, Poland
1 shared publication - Jonas Vanagas
Faculty of Electronics, Vilnius Gediminas Technical University, 10223 Vilnius, Lithuania
1 shared publication - Kristián Eliáš
Department of Electric Power Engineering, Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 1/9, 040 01 Košice, Slovakia
1 shared publication
Latest Publications
- Open Access
- 23 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (19) , 9453
Analysis of the Readiness of Low-Voltage Distribution Networks for Decentralized Energy: A Case Study of a Real Distribution Network Using Smart Meter Data
Decentralized energy sources are currently an integral part of low-voltage distribution networks. In line with the energy policy of the European Union, it can be expected that their penetration in these networks will continue to grow. But are distribution networks prepared for such a future? This study addresses this question using data measured over 30 days in a real low-voltage distribution network where PV systems are installed at 18% of the consumption points. In cooperation with a Polish distribution system operator, all consumption points were equipped with smart meters, which allowed the voltage magnitude, voltage unbalance, and transferred power to be evaluated at 51 measurement points simultaneously. Data analysis shows that decentralized sources significantly affect power flows and the overall active power balance, which is directly reflected in the network’s voltage profile. A surplus of active power was recorded on 29 of the 30 days and raised the voltage above the upper limit defined by the EN 50160 standard on 27 of them. The hosting capacity of the analyzed network is therefore already exceeded at the current penetration, and the network is not ready to integrate further decentralized sources in line with European Union energy targets.
- 23 September 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (19) , 9453
Open AccessAnalysis of the Readiness of Low-Voltage Distribution Networks for Decentralized Energy: A Case Study of a Real Distribution Network Using Smart Meter Data
Decentralized energy sources are currently an integral part of low-voltage distribution networks. In line with the energy policy of the European Union, it can be expected that their penetration in these networks will continue to grow. But are distribution networks prepared for such a future? This study addresses this question using data measured over 30 days in a real low-voltage distribution network where PV systems are installed at 18% of the consumption points. In cooperation with a Polish distribution system operator, all consumption points were equipped with smart meters, which allowed the voltage magnitude, voltage unbalance, and transferred power to be evaluated at 51 measurement points simultaneously. Data analysis shows that decentralized sources significantly affect power flows and the overall active power balance, which is directly reflected in the network’s voltage profile. A surplus of active power was recorded on 29 of the 30 days and raised the voltage above the upper limit defined by the EN 50160 standard on 27 of them. The hosting capacity of the analyzed network is therefore already exceeded at the current penetration, and the network is not ready to integrate further decentralized sources in line with European Union energy targets.
- Open Access
- 26 August 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Using selected flexibility resources in the power system to eliminate overloads on high-voltage lines
- 26 August 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 265
Open AccessUsing selected flexibility resources in the power system to eliminate overloads on high-voltage lines
- Open Access
- 4 March 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (5) , 2489
Operational Optimisation of the Medium-Voltage Network Containing Renewable Energy Sources and Energy Storage
The rapid growth of renewable electricity generation introduces technical challenges that were previously uncommon. These include, for example, problems with exceeding the permissible voltage values in network nodes, overloading of transformers and line sections located behind the transformer, as well as balance problems. This article proposes an original methodology for eliminating these problems. Four objective functions reflecting different operator priorities were used. Attention is drawn to the increasing importance of the development of electricity storage. The results confirm that coordinated optimisation of voltage regulation, energy storage, and flexible load management enables increased renewable energy connection capacity while reducing power losses and improving the grid voltage profile. The case study results demonstrate the effectiveness of the proposed approach under the considered operating scenarios. The proposed tool can support network operators in managing MV grid operation under the considered scenarios. The ongoing energy transition requires network operators to react quickly to emerging problems. Therefore, advanced computational methods are needed to mitigate operational risks and respond to emerging constraints.
- 4 March 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (5) , 2489
Open AccessOperational Optimisation of the Medium-Voltage Network Containing Renewable Energy Sources and Energy Storage
The rapid growth of renewable electricity generation introduces technical challenges that were previously uncommon. These include, for example, problems with exceeding the permissible voltage values in network nodes, overloading of transformers and line sections located behind the transformer, as well as balance problems. This article proposes an original methodology for eliminating these problems. Four objective functions reflecting different operator priorities were used. Attention is drawn to the increasing importance of the development of electricity storage. The results confirm that coordinated optimisation of voltage regulation, energy storage, and flexible load management enables increased renewable energy connection capacity while reducing power losses and improving the grid voltage profile. The case study results demonstrate the effectiveness of the proposed approach under the considered operating scenarios. The proposed tool can support network operators in managing MV grid operation under the considered scenarios. The ongoing energy transition requires network operators to react quickly to emerging problems. Therefore, advanced computational methods are needed to mitigate operational risks and respond to emerging constraints.
- Open Access
- 26 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (5) , 2279
Evaluation of the Power System’s Connection Capabilities Using Nonlinear Optimisation with Simulated Annealing
This article presents nonlinear optimisation as a tool for determining the maximum power output of renewable energy sources connected to the transmission grid. The goal of the developed model is to maximise the total power generated by these sources while taking into account the technical and operational constraints of the system. These include permissible load on transmission lines and transformers, cross-border exchange balance limits, and the “must run” limits for the operation of conventional power plants. Particular attention was paid to meeting the N-1 safety criterion, which assumes the system’s resilience to infrastructure failures. Appropriate conditions for post-failure states were incorporated into the set of optimisation constraints. A heuristic simulated annealing algorithm was used to solve the problem, enabling the search for globally optimal solutions in a discontinuous and highly nonlinear space. The calculations yielded a generation vector for renewable energy sources connected to individual grid nodes, thus ensuring maximum utilisation of the available renewable energy potential under the given system conditions. The effectiveness and efficiency of the proposed approach are illustrated with the example of a test network.
- 26 February 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (5) , 2279
Open AccessEvaluation of the Power System’s Connection Capabilities Using Nonlinear Optimisation with Simulated Annealing
This article presents nonlinear optimisation as a tool for determining the maximum power output of renewable energy sources connected to the transmission grid. The goal of the developed model is to maximise the total power generated by these sources while taking into account the technical and operational constraints of the system. These include permissible load on transmission lines and transformers, cross-border exchange balance limits, and the “must run” limits for the operation of conventional power plants. Particular attention was paid to meeting the N-1 safety criterion, which assumes the system’s resilience to infrastructure failures. Appropriate conditions for post-failure states were incorporated into the set of optimisation constraints. A heuristic simulated annealing algorithm was used to solve the problem, enabling the search for globally optimal solutions in a discontinuous and highly nonlinear space. The calculations yielded a generation vector for renewable energy sources connected to individual grid nodes, thus ensuring maximum utilisation of the available renewable energy potential under the given system conditions. The effectiveness and efficiency of the proposed approach are illustrated with the example of a test network.
- Open Access
- 21 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12399
Linear Approximations of Power Flow Equations in Electrical Power System Modelling—A Review of Methods and Their Applications
The power system is constantly changing. New elements are being added. The network structure is being changed. Existing network infrastructure is being modernised. This results in the need to perform various types of computational analyses. These analyses are designed to assess the impact of new and existing power system components on its operation. These analyses can be complicated, complex and difficult. These analyses are influenced by the size of the actual grid, technical conditions, and the specific requirements of grid operators. Therefore, there is a constant search for methods that simplify them without significantly compromising the accuracy of the obtained results. In real networks, computation time is also a crucial parameter, which can be excessive when analysing multiple operating variants. Linearisation of the computational model significantly contributes to reducing computational time but also affects their accuracy. Particular attention should be paid to two frequently used and compared linearization methods: the DC method and the first-order Taylor expansion. The DC (Direct Current) method offers relatively simple formulas. These relationships are based on simplifying assumptions. They are well suited for error analysis, at the expense of neglecting reactive power and voltage changes. Taylor linearization preserves the full AC structure around a selected operating point. It takes reactive power and voltage changes into account. Its accuracy is local and depends on the base point. It may require re-linearization for large changes in the power system operating states. This article presents a detailed literature review. It concerns the linearization of the power flow problem in the context of solving various computational problems in the power system. Selected works are grouped and categorised by topic. Linearisation methods used in the literature are presented, and the most frequently used ones are also indicated. Research gaps that may be addressed in future work are highlighted.
- 21 November 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (23) , 12399
Open AccessLinear Approximations of Power Flow Equations in Electrical Power System Modelling—A Review of Methods and Their Applications
The power system is constantly changing. New elements are being added. The network structure is being changed. Existing network infrastructure is being modernised. This results in the need to perform various types of computational analyses. These analyses are designed to assess the impact of new and existing power system components on its operation. These analyses can be complicated, complex and difficult. These analyses are influenced by the size of the actual grid, technical conditions, and the specific requirements of grid operators. Therefore, there is a constant search for methods that simplify them without significantly compromising the accuracy of the obtained results. In real networks, computation time is also a crucial parameter, which can be excessive when analysing multiple operating variants. Linearisation of the computational model significantly contributes to reducing computational time but also affects their accuracy. Particular attention should be paid to two frequently used and compared linearization methods: the DC method and the first-order Taylor expansion. The DC (Direct Current) method offers relatively simple formulas. These relationships are based on simplifying assumptions. They are well suited for error analysis, at the expense of neglecting reactive power and voltage changes. Taylor linearization preserves the full AC structure around a selected operating point. It takes reactive power and voltage changes into account. Its accuracy is local and depends on the base point. It may require re-linearization for large changes in the power system operating states. This article presents a detailed literature review. It concerns the linearization of the power flow problem in the context of solving various computational problems in the power system. Selected works are grouped and categorised by topic. Linearisation methods used in the literature are presented, and the most frequently used ones are also indicated. Research gaps that may be addressed in future work are highlighted.