PKPeifeng Ke

Peifeng Ke

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Peifeng Ke has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Xianzhang Huang

    Department of Laboratory Medicine/State Key Laboratory of Dampness Syndrome of Chinese Medicine The Second Affiliated Hospital of Guangzhou University of Chinese Medicine Guangzhou China

    4 shared publications
  • Zemin Wan

    Department of Laboratory Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China

    4 shared publications
  • Xiaobin Wu

    Development Center of Plant Germplasm Resources, College of Life Sciences, Shanghai Normal University, Shanghai 200234, China

    3 shared publications
  • Yunxiu Wang

    Department of Laboratory Medicine , The Second Affiliated Hospital of Guangzhou University of Chinese Medicine , Guangzhou , P.R. China

    3 shared publications
  • Feng Qiu

    School of Chinese Materia Medica, Tianjin University of Traditional Chinese Medicine, Tianjin, China

    2 shared publications
  • Hongcan Liu

    Department of Laboratory Medicine , The Second Affiliated Hospital of Guangzhou University of Chinese Medicine , Guangzhou , P.R. China

    2 shared publications

Latest Publications

  • Open Access

    Effects of sample handling on the stability of interleukin-6 in patients with breast neoplasms

    by Yunxiu Wang, Baiye Wang, Lanhui She, Jijuan Wang, Yingting Chen, Di Huang, Guang Han, Miaolian Lu, Xiaobin Wu, Zemin Wan, et al.

    Objectives: To investigate the influence of preservation methods and processes on the plasma interleukin-6 (IL-6) stability. Methods: Lithium-heparin plasma was collected from female patients: 32 female patients with invasive breast neoplasms and 20 healthy females. Each sample was divided into three tubes. Samples were stored at different temperatures or at different times. The concentration of IL-6 was detected. Results: IL-6 levels in patients were not altered significantly compared to the control group after storage at 4 °C or 25 °C for 12 h. However, IL-6 levels were significantly higher compared to controls (p<0.05) after storage at 25 °C for 48 h. IL-6 levels in patients with breast neoplasms were significantly higher compared to the control group (p<0.05) when stored at 4 °C after 12 h. IL-6 levels in patients with breast neoplasm increased more than 10-folds compared to the control group after only 2 h storage at 25 °C. Conclusions: Concentrations of IL-6 in breast neoplasms samples significantly change under different storage conditions. Pretreatment needs to be standardized for blood sample handling procedure. Comparison of different storage conditions of IL-6 levels may not be reliable.


  • Open Access

    Design and Evaluation of Multiplex One-Step Reverse Transcription PCR–Dipstick Chromatography Method for the Analysis of Seven Respiratory Pathogens

    by Li Luo, Qianming Chen, Sheng Qin, Qiang Luo, Zhenjie Liu, Qiong Li, Shuilan Zheng, Xianzhang Huang, Peifeng Ke, Xiangsheng Yang, et al.

    Influenza A, influenza B, severe acute respiratory syndrome coronavirus 2, adenovirus, respiratory syncytial virus, Mycoplasma pneumoniae, and Chlamydophila pneumoniae are common pathogens that can cause severe pneumonia and other symptoms, resulting in acute lower respiratory tract infections. The objective of this study was to design and evaluate a sensitive and specific multiplex one-step reverse transcription PCR (RT-PCR)–dipstick chromatography method for simultaneous rapid detection of these seven pathogens. Streptavidin-coated blue latex particles were used to read out a positive signal. Based on the DNA–DNA hybridization of oligonucleotide sequences (Tag) for forward primer with the complementary oligonucleotide sequence (cTag) on the dipstick and biotin–streptavidin interactions, PCR products were able to be illuminated visually on the dipstick. The specificity and the limit of detection (LOD) were also evaluated. Moreover, the clinical performance of this method was compared with Sanger sequencing for 896 samples. No cross reaction with other pathogens was found, confirming the high specificity of this method. The LOD was 10 copies/µL for each of the tested pathogens, and the whole procedure took less than 40 min. Using 896 samples, the sensitivity and specificity were shown to be no lower than 94.5%. The positive predictive value was higher than 82.1%, and the negative predictive value was higher than 99.5%. The kappa value between the PCR–dipstick chromatography method and Sanger sequencing ranged from 0.869 to 0.940. In summary, our one-step RT-PCR–dipstick chromatography method is a sensitive and specific tool for rapidly detecting multiplex respiratory pathogens.


  • Open Access

    Inflammation Pharmacological Reaction and YMDD Mutational Patterns in Lamivudine Therapeutics Hepatitis B Virus

    by Hongcan Liu, Zemin Wan, Lanhui She, Yajuan Zhu, Zhiliang Cai, Bin Wu, Qizhen Zhuang, Peifeng Ke, Xinzhong Wu, Zhuo Li, et al.

    Background/Aims: Emergence of tyrosine-methionine-aspartate-aspartate (YMDD) motif in reverse transcriptase is a serious problem in chronic hepatitis B(CHB) patients after Lamivudine (LAM) therapy. However, the relationship between inflammation pharmacological reaction and YMDD mutational patterns of CHB has not been well-characterized. The aim of this study was to investigate the inflammation pharmacological reaction and different YMDD mutants patterns of CHB patients.Methods: We investigated the inflammation pharmacological reaction and YMDD mutational patterns through biochemical, serological and virological detection among 83 CHB patients, including 25 YMDD mutants, 25 under detection, and 33 control patients without YMDD mutants.Results: Prevalence of YMDD mutation patterns is different. Among 25 YMDD mutants patients, YIDD was the dominant mutation (72%), followed YVDD (16%) and the hybrid YIDD + YVDD (12%). The time course during the YMDD mutations was also different. 52.4% patients developed the mutation less than 12 months after the LAM therapy. Serum hepatitis B virus (HBV) DNA level in patients with YMDD mutants were significantly higher than that in control and negative groups. Serum HbsAg and HbeAg in patients with YMDD mutants were also higher than those in control and negative groups, despite no significant difference was found forserum HbeAb. ALT and AST levels were also significantly higher in mutants group.Conclusions: Illuminating inflammation pharmacological reaction and YMDD mutational patterns of CHB during pathological process may have implications for future therapy in YMDD mutation patients. This may have impact on the choice of treatment strategies for lamivudine-resistant HBV.


  • Deafness Gene Mutations in Newborns in the Foshan Area of South China With Bloodspot-Based Genetic Screening Tests

    by Shunwang Cao, Yanhua Sha, Peifeng Ke, Tingting Li, Weixi Yuan, Xianzhang Huang

    Purpose: The aim of this study was to determine the rate of deafness gene mutations in the Foshan area of South China. Method: We enrolled the infants delivered in Foshan Maternity and Children's Healthcare Hospital. Deafness gene mutation was detected by HibriMax method. Our study tested 47,538 newborns within 3 days after birth, including 13 sites in four genes: GJB2 (c.35 del G, c.176 del 16, c.235 del C, c.299 del AT, c.155 del TCTG), GJB3 (c.583 C>T), SLC26A4 (c.2168 A>G, c.919-2 A>G, c.1299 C>T), and mtDNA 12S rRNA (m.1555 A>G, m.1494 C>T, m.12201 T>C, m.7445 A>G). The birth condition of infants was collected, including sex, low or high birth weight, twins, and premature delivery. Results: In a total of 47,538 newborns, 1,415 were positively identified with deafness gene mutations. The total rate of the deafness gene mutation was 2.976%. The carrier rates of GJB2 (c.35 del G, c.176 del 16, c.235 del C, c.299 del AT, c.155 del TCTG), GJB3 (c.583 C>T), SLC26A4 (c.2168 A>G, c.919-2 A>G, c.1299 C>T), and mtDNA 12S rRNA (m.1555 A>G, m.1494 C>T, m.12201 T>C, m.7445 A>G) mutations were 0.000%, 0.048%, 1.422%, 0.185%, 0.000%, 0.076%, 0.116%, 0.755%, 0.160%, 0.187%, 0.021%, 0.000%, and 0.006%, respectively. Conclusions: Our study showed that the c.235 del C GJB2 mutation was the leading deafness-related mutation in the Foshan area of South China. Deafness gene mutations screening in newborns detected by bloodspot-based genetic screening tests can help the diagnosis of newborn congenital hearing loss.


  • Interference of Thalassemias on Hemoglobin A1c Measurement by Ion-Exchange High-Performance Liquid Chromatography Method Tosoh HLC-723 G8

    by Yan Chao, Zemin Wan, Xiaobin Wu, Feng Qiu, Yunxiu Wang, Peifeng Ke, Xinzhong Wu, Jianhua Xu, Junhua Zhuang, Xianzhang Huang

    The presence of hemoglobinopathies could interfere with some assays for Hemoglobin A1c (HbA1c) measurement; therefore, the effect of thalassemia on ion-exchange high-performance liquid chromatography (IEHPLC) method Tosoh HLC-723 G8 (Tosoh G8) was evaluated. A total of 43 normal controls and 101 thalassemia patients were quantified by Premier Hb9210 and Tosoh G8 (variant-mode) systems. At the same time, 7 normal controls and 8 thalassemia patients were confirmed by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) reference method for verification. For normal controls, the HbA1c values of Tosoh G8 system (y) showed great correlation and agreement with those from Premier Hb9210 (x) (y = 0.9688x + 0.2151, r = 0.9951; mean difference 0.02 ± 0.30%), and no significant relative bias above 7% was observed; the HbA1c values obtained by Tosoh G8 were consistent with the IFCC targets (relative bias < ± 6%) in all of the samples. However, for thalassemia, the correlation between Tosoh G8 (y) and Premier Hb9210 (x) became relatively low (y = 0.8079x + 1.2897, r = 0.7780); the HbA1c values of 91.1% of the samples (92/101) obtained by Tosoh G8 were higher than those by Premier Hb9210 (mean difference 0.33 ± 0.48%) and a significant positive bias above 7% was noticed in 43.3% (45/101) thalassemia patients; when compared with the IFCC targets, the 87.5% (7/8) relative bias was > ± 6%. Thalassemia could directly affect the measurement of HbA1c using the IE-HPLC method Tosoh G8 and the clinical laboratorial staff should pay close attention.


  • Open Access

    Identification of haemoglobin New York by haemoglobin A 1c measurement using the Sebia Capillarys 2 Flex Piercing system

    by Yan Chao, Zemin Wan, Xiaobin Wu, Feng Qiu, Xinzhong Wu, Yunxiu Wang, Peifeng Ke, Jianhua Xu, Junhua Zhuang, Xianzhang Huang

    Haemoglobinopathies may interfere with the haemoglobin A 1c (HbA 1c ) measurement, leading to incorrect diagnosis and inappropriate treatment. It is essential that HbA 1c assays are capable of identifying haemoglobinopathies. We report two cases of haemoglobin New York (HbNY) discovered through HbA 1c analysis using capillary electrophoresis (Capillarys 2 Flex Piercing [C2FP], Sebia). We used these samples to evaluate the ability of three other HbA 1c assays to identify this variant: ion-exchange high-performance liquid chromatography (Variant II Turbo [VII-T], Bio-Rad); boronate affinity high-performance liquid chromatography (Ultra 2 , Trinity Biotech) and immunoassay (Cobas c501 Tina-quant Generation 3, Roche Diagnostics). Each method was used for HbA 1c assay of in samples from two cases of heterozygous haemoglobinopathy: β 0 -thalassemia/HbNY (Case 1) and HbA/NY (Case 2). Only the C2FP system detected HbNY (an additional peak appeared between HbA 1c and HbA 0 ). Clinical laboratories should be aware of the limitations of their HbA 1c assay methods especially in geographic areas, where haemoglobinopathy prevalence is high.