AHAles Hamacek

Ales Hamacek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ales Hamacek has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Washing Resistance of Textile Ribbon Dismountable Interconnections in Smart Textiles

    by Karel Sima, Jan Reboun, Daniela Moravcova, Lucie Svecova, David Kalas, Radek Soukup, Ales Hamacek

    This paper is focused on the stability and reliability of interconnections in smart textiles between textile ribbons and other smart textiles functional blocks. There was selected one interconnection method based on the pin/connector crimping. Two commercially available crimps were chosen for testing. The testing showed the possibility of this method for the usage of crimps in smart textiles. The testing was done by multiple clothes washing cycles according to ISO 6330.


  • Reliability of Glued SMD Components on Smart Textile

    by Martin Hirman, Jiri Navratil, Frantisek Steiner, Ales Hamacek

    The paper deals with temperature ageing reliability of joints glued by non-conductive adhesive (NCA) onto the conductive ribbon. The samples prepared with NCA were accelerated aged at 85 °C temperature for 1000 hours. The samples were also stretched on 150 % of their relaxed length during the ageing. The main aim of the experiment was to verify the possibility of NCA using to make a conductive connection of components onto the ribbon. The joints electrical resistance was measured before, during and after ageing. The results show that using this technology for standard use of ribbons is suitable and reliable.


  • Fully Printed IoT Antenna for Drone-Deployed Autonomous Sensor Unit

    by Martin Pavec, Jiri Navratil, Radek Soukup, Vaclav Smitka, Ales Hamacek

    This paper presents research focused on the development of a flexible fully printed IoT antenna for a drone-deployed autonomous sensor unit optimized for IoT applications. Aerosol Jet® was chosen as manufacturing technology. DuPont™ Kapton® HN 500 polyimide foil was used as a substrate. Conductive silver nanoparticle ink Clariant Prelect TPS50 was used for printing the antenna. Antennas were prepared with the different number of printed layers. A demonstrator with the fully printed flexible antenna was fabricated by Aerosol Jet printing technology and tested.


  • Aerosol Jet silver printed lines on subsequently bent glass substrates

    by Jiri Navratil, Martin Pavec, Jan Reboun, Tomas Rericha, Ales Hamacek

    This paper presents a research focused on Aerosol Jet printed lines on subsequently bent glass substrates. The thin glass rods were used as the glass substrates. Three different patterns were printed by silver nanoparticle ink on the thin rods and the ink was sintered. The thin rods were bent in a flame in different angles after the ink sintering. The resistivity was measured before and after the bending and also the microscopic observation was realized in order to discover which of the printed patterns is the best for bending.


  • Smart textile-based protective system for firefighters

    by R. Soukup, T. Blecha, A. Hamacek, J. Reboun

    This paper presents a research focused on a smart textile-based protective system which is intended to bring more safety to firefighters facing hazardous conditions. The system is fully integrated into a firefighter protective suit and it is able to monitor heart rate (HR), to detect movements of a firefighter, to detect toxic and combustible gases in the environment and to measure temperature (T) and relative humidity (RH) inside and outside of the suit. The protective system consists of developed integrated sensor modules, e-textile wiring harnesses, body control unit (BCU), central processing unit (CPU), body area network (BAN) and wide area network (WAN). The measured data are wirelessly transmitted over a wide area network with automatic routing algorithm to the central processing unit, which is checked by a firefighter operation chief, who is kept informed about an actual state of individual fire fighters. In case that some monitored parameter oversteps pre-set threshold values the BCU will automatically inform a fire fighter by means of acoustic alarm about oncoming risk.


  • Sensorial characteristics of conductive polymers

    by Jan Reboun, Ales Hamacek, Tomas Dzugan, Michael Kroupa

    This paper deals with the investigation of intrinsic conductive polymer PEDOT-PSS and development of vapour sensors. These sensors are based on the specific vapours influence on the electrical parameters. The designed sensors consist of glazed ceramic substrate with gold interdigital electrodes covered by a thin layer of conductive polymer. The insulation gap between electrodes was investigated in the range of 50 - 200 mum in order to achieve the maximal sensitivity. Temperature and humidity dependences of PEDOT-PSS layers were measured in the climatic chamber, influence of particular vapours on electrical parameters were measured in the special gas chamber. Except for temperature, humidity and vapour sensitivity, long term stability was also studied.