Arnold S. de Beer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arnold S. de Beer has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Adrianus Johannes Han Vinck
Institute of Digital Signal Processing, University of Duisburg-Essen, 47057 Duisburg, Germany
4 shared publications - Hendrik Christoffel Ferreira
University of Johannesburg, Auckland Park, Johannesburg, South Africa
4 shared publications A. Emleh
Department of Electrical and Electronic Engineering Science, University of Johannesburg, P.O. Box 524, Auckland Park, 2006, South Africa
1 shared publicationA. Sheri
Department of Electrical and Electronic Engineering Science, University of Johannesburg, P. O. Box 524, Auckland Park, 2006, South Africa
1 shared publicationAllan Emleh
Department of Electrical and Electronic Engineering Science, University of Johannesburg, P.O. Box 524, Auckland Park, 2006, South Africa
1 shared publication- Petrus A. Janse van Rensburg
Central Queensland University, Mackay, Australia
1 shared publication
Latest Publications
- Open Access
- 15 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Gate Drives generating EMI in the absence of Power Converter loading
This paper shows how a power converter can generate electromagnetic interference (EMI) through the operation of gate drives only - in the absence of any power conversion. This is due to parasitic capacitances connecting the power semiconductor’s gate to the main circuit. A half bridge converter is used to illustrate this concept. Practical measurements are compared to simulations for an energized and non-energized converter. Even without loading, a converter can exceed regulatory conducted emission EMI limits. This effect is important to consider during the design of converter EMI mitigation - especially for low power converters where the load current is not dominant.
- 15 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in TechRxiv
Open AccessGate Drives generating EMI in the absence of Power Converter loading
This paper shows how a power converter can generate electromagnetic interference (EMI) through the operation of gate drives only - in the absence of any power conversion. This is due to parasitic capacitances connecting the power semiconductor’s gate to the main circuit. A half bridge converter is used to illustrate this concept. Practical measurements are compared to simulations for an energized and non-energized converter. Even without loading, a converter can exceed regulatory conducted emission EMI limits. This effect is important to consider during the design of converter EMI mitigation - especially for low power converters where the load current is not dominant.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Channel frequency response for a low voltage indoor cable up to 1GHz
The Channel Frequency Response (CFR) is essential in the understanding and specification of Power Line Communications (PLC) equipment. In this paper a 10m indoor low voltage Flat Twin and Earth power cable is characterized up to 1GHz. This is higher in frequency than existing PLC specifications. This is done because the effect of frequencies in the upper VHF and lower UHF bands on PLC is largely unknown. Measurements and simulation are used to show that at higher frequencies, the traditional transmission line models of wave propagation on a power line are no longer valid. Classic attenuation models do not predict the correct CFR above typically 250MHz for a 10m cable. This effect is explained in terms of electromagnetic radiation from the cable. After 500MHz it is speculated that the line becomes a waveguide. These transmission modes have important implications for UHF PLC, either directly (connected cable) or when used in contactless mode where the power line is used as antenna.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Channel frequency response for a low voltage indoor cable up to 1GHz
The Channel Frequency Response (CFR) is essential in the understanding and specification of Power Line Communications (PLC) equipment. In this paper a 10m indoor low voltage Flat Twin and Earth power cable is characterized up to 1GHz. This is higher in frequency than existing PLC specifications. This is done because the effect of frequencies in the upper VHF and lower UHF bands on PLC is largely unknown. Measurements and simulation are used to show that at higher frequencies, the traditional transmission line models of wave propagation on a power line are no longer valid. Classic attenuation models do not predict the correct CFR above typically 250MHz for a 10m cable. This effect is explained in terms of electromagnetic radiation from the cable. After 500MHz it is speculated that the line becomes a waveguide. These transmission modes have important implications for UHF PLC, either directly (connected cable) or when used in contactless mode where the power line is used as antenna.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 251-254
Influence of LED tubes on the throughput of an indoor broadband PLC channel
This paper shows how Light Emitting Diode (LED) Tubes negatively influence the data rate throughput of an indoor broadband Power Line Communications (PLC) channel. This negative influence on the data rate is due to noise being generated by the lamps. Differential Mode measurements were done with two PLC modems communicating and then introducing LED lamps that add noise to the channel. Drops in data throughput rates were measured and compared to a clean (no noise) channel. A significant decrease (up to 50%) in throughput was observed which can have important implications for applications of PLC in the presence of LED Tubes.
- 1 July 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 251-254
Influence of LED tubes on the throughput of an indoor broadband PLC channel
This paper shows how Light Emitting Diode (LED) Tubes negatively influence the data rate throughput of an indoor broadband Power Line Communications (PLC) channel. This negative influence on the data rate is due to noise being generated by the lamps. Differential Mode measurements were done with two PLC modems communicating and then introducing LED lamps that add noise to the channel. Drops in data throughput rates were measured and compared to a clean (no noise) channel. A significant decrease (up to 50%) in throughput was observed which can have important implications for applications of PLC in the presence of LED Tubes.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 172-177
The influence of high pressure sodium lamps on the power line communications channel
The high pressure sodium lamp is a high energy outdoor light source that belongs to the high intensity discharge lamp family. It comes in different shapes and requires a ballast to start it. The high pressure sodium lamp is a source of interference to the power line communications channel as it injects noise when connected to the 220V mains. This paper investigates the influence of the high pressure sodium lamp on the narrowband and broadband power line communications channel. It is shown that the frequency band: 3kHz-150kHz is not highly infected whereas in the band: 150kHz-30MHz, PLC signals compete with Electromagnetic Compatibility (EMC) levels.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 172-177
The influence of high pressure sodium lamps on the power line communications channel
The high pressure sodium lamp is a high energy outdoor light source that belongs to the high intensity discharge lamp family. It comes in different shapes and requires a ballast to start it. The high pressure sodium lamp is a source of interference to the power line communications channel as it injects noise when connected to the 220V mains. This paper investigates the influence of the high pressure sodium lamp on the narrowband and broadband power line communications channel. It is shown that the frequency band: 3kHz-150kHz is not highly infected whereas in the band: 150kHz-30MHz, PLC signals compete with Electromagnetic Compatibility (EMC) levels.
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 35-40
A preliminary investigation of the UHF properties of LV cable for WiFi over power line communications
In pursuit of a wireless (contactless) power line communications (W-PLC) system for low voltage (LV) power distribution networks, a commonly utilized bundled low voltage electrical cable called Cabtyre, was energized with a range of frequencies up to 3 GHz. The intention was to characterize the cable from a radio frequency radiation perspective for the utilization of standard low voltage distribution cables as antennas in ultra high frequency (UHF) PLC systems. The range of test frequencies extends 550 MHz beyond the present IEEE 802.11g protocol which has a centre frequency of 2.45 GHz and a 80 MHz total bandwidth. The applied tests therefore allow adequately for the maximum bandwidth required with 40 MHz modulation on either side of the 2.45 GHz centre frequency, [1].
- 1 March 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 35-40
A preliminary investigation of the UHF properties of LV cable for WiFi over power line communications
In pursuit of a wireless (contactless) power line communications (W-PLC) system for low voltage (LV) power distribution networks, a commonly utilized bundled low voltage electrical cable called Cabtyre, was energized with a range of frequencies up to 3 GHz. The intention was to characterize the cable from a radio frequency radiation perspective for the utilization of standard low voltage distribution cables as antennas in ultra high frequency (UHF) PLC systems. The range of test frequencies extends 550 MHz beyond the present IEEE 802.11g protocol which has a centre frequency of 2.45 GHz and a 80 MHz total bandwidth. The applied tests therefore allow adequately for the maximum bandwidth required with 40 MHz modulation on either side of the 2.45 GHz centre frequency, [1].