Hao Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hao Wu has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Fengjiao Gan
School of Communication Engineering, Hangzhou Dianzi University, Hangzhou, China
1 shared publication - Xu Chen
College of Information and Communication Engineering, Harbin Engineering University, Harbin, China
1 shared publication
Latest Publications
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 32 (10709908) , 4464-4468
Wide Field-of-View MMW SISO-SAR Image Reconstruction Based on Curved Linear Array
This paper presents a wide field-of-view (FoV) millimeter-wave array synthetic aperture radar (SAR) imaging system based on curved linear array. The proposed system retains the low-cost advantage of planar scanning array SARs while offering a broader viewing angle. However, the significant disparity in spatial sampling density across different regions of the sampling aperture results in suboptimal imaging performance when employing the classical back-projection algorithm (BPA). To address this issue, we introduce a measurement-fusion imaging algorithm tailored for this system, which involves constructing uniformly sampled sub-apertures and calculating spatial grid weights. This approach significantly enhances image integrity and mitigates artifacts and sidelobes. Experiments demonstrate high-quality imaging with an extended FoV.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 32 (10709908) , 4464-4468
Wide Field-of-View MMW SISO-SAR Image Reconstruction Based on Curved Linear Array
This paper presents a wide field-of-view (FoV) millimeter-wave array synthetic aperture radar (SAR) imaging system based on curved linear array. The proposed system retains the low-cost advantage of planar scanning array SARs while offering a broader viewing angle. However, the significant disparity in spatial sampling density across different regions of the sampling aperture results in suboptimal imaging performance when employing the classical back-projection algorithm (BPA). To address this issue, we introduce a measurement-fusion imaging algorithm tailored for this system, which involves constructing uniformly sampled sub-apertures and calculating spatial grid weights. This approach significantly enhances image integrity and mitigates artifacts and sidelobes. Experiments demonstrate high-quality imaging with an extended FoV.