Sifan Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sifan Cao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Danni Ai
Beijing Institute of Technology
1 shared publication - Dawei Lu
Beijing Institute of Technology
1 shared publication - Deqiang Xiao
Beijing Institute of Technology
1 shared publication - Hong Song
Beijing Institute of Technology
1 shared publication - Jian Yang
Beijing Institute of Technology
1 shared publication - Jingfan Fan
Beijing Institute of Technology
1 shared publication
Latest Publications
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Intraoperative Tumor-Augmented Imaging Method via a Graph-Optimized Fusion Framework of Endoluminal and External Endoscopic Vision
Accurate intraoperative localization of luminal tumors is crucial for effective resection. However, the limited field of view of endoscopes hinders lesion visualization from the external operative perspective. Furthermore, existing endoscopic fusion navigation techniques struggle to align endoscopic images with preoperative CT scans after deformation of flexible organs. To address this, we propose a novel tumor-augmented imaging method that reconstructs tumor morphology from Intracavitary Endoscopy (IE) images and, by leveraging spatial relationships among sensors, fuses the lesion onto multiple non-fixed Laparoscopic/ Scene Cameras (L/SCs). To mitigate multi-source uncertainties in calibrating external visual coordinate systems, we proposed a graph-optimization-based multi-loop constraint calibration framework. The framework is first modeled as a directed graph, followed by a parameter-sharing strategy leveraging a covariance-weighted approach to quantitatively characterize sensor uncertainty. Building on this, a reprojection error function is constructed for multiple non-fixed camera systems to globally optimize the hand-eye calibration matrix, enabling accurate fusion of tumors reconstructed from absolute tracking data into their corresponding positions in the external views. Experiments on self-built and public calibration datasets demonstrate state-of-the-art accuracy and strong robustness to sensor noise. Ex vivo studies validate the reliability of tumor fusion onto external views, providing a novel fusion-guided surgery navigation method for intraoperative tumor localization.
- 21 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Intraoperative Tumor-Augmented Imaging Method via a Graph-Optimized Fusion Framework of Endoluminal and External Endoscopic Vision
Accurate intraoperative localization of luminal tumors is crucial for effective resection. However, the limited field of view of endoscopes hinders lesion visualization from the external operative perspective. Furthermore, existing endoscopic fusion navigation techniques struggle to align endoscopic images with preoperative CT scans after deformation of flexible organs. To address this, we propose a novel tumor-augmented imaging method that reconstructs tumor morphology from Intracavitary Endoscopy (IE) images and, by leveraging spatial relationships among sensors, fuses the lesion onto multiple non-fixed Laparoscopic/ Scene Cameras (L/SCs). To mitigate multi-source uncertainties in calibrating external visual coordinate systems, we proposed a graph-optimization-based multi-loop constraint calibration framework. The framework is first modeled as a directed graph, followed by a parameter-sharing strategy leveraging a covariance-weighted approach to quantitatively characterize sensor uncertainty. Building on this, a reprojection error function is constructed for multiple non-fixed camera systems to globally optimize the hand-eye calibration matrix, enabling accurate fusion of tumors reconstructed from absolute tracking data into their corresponding positions in the external views. Experiments on self-built and public calibration datasets demonstrate state-of-the-art accuracy and strong robustness to sensor noise. Ex vivo studies validate the reliability of tumor fusion onto external views, providing a novel fusion-guided surgery navigation method for intraoperative tumor localization.