Esther Martinez Parrón
Research Subjects
Research Interests
Esther Martinez Parrón has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Agustín Martínez Albiñana
AniCura Aitana Hospital Veterinario, C/de Xirivella, 16, 46920 Mislata, Valencia, Spain
1 shared publication - Ariel Cañón Pérez
Department of Animal Pathology, Faculty of Veterinary Medicine, University of Zaragoza, Spain
1 shared publication - Eva Zoe Hernández-Magaña
Departamento Medicina y Cirugía Animal, Facultad de Veterinaria, Universidad Cardenal Herrera-CEU, CEU Universities, 46115 Valencia, Spain
1 shared publication - Jaime Viscasillas
Anicura Valencia Sur Hospital Veterinario, Picassent 28, 46460 Silla Valencia, Spain
1 shared publication - Jose Ignacio Redondo
Departamento Medicina y Cirugía Animal, Facultad de Veterinaria, Universidad Cardenal Herrera—CEU, CEU Universities, 46115 Valencia, Spain
1 shared publication - Jose Manuel Gómez-Silvestre
London Vet Specialists, London, UK
1 shared publication
Latest Publications
- Open Access
- 22 November 2025
- Published by MDPI AG in Veterinary Sciences
- Vol. 12 (12) , 1112
Evaluation of the V-gel® Advanced Supraglottic Airway Device Across Different Ventilatory Modes in Anaesthetised Cats
Endotracheal intubation in cats carries risks; supraglottic airway devices (SADs) offer a less invasive alternative. This prospective clinical study evaluated the V-gel® advanced in cats undergoing ovariohysterectomy, with the primary aim of intra-anaesthetic gas leakage; secondary aims were ease of placement, complications, and the effect of device re-use. Spirometric inspired/expired tidal volumes were recorded under predefined ventilatory settings; leakage was calculated and analysed. Of 52 cats enrolled, 47 were analysed. Leakage occurred in 13% during spontaneous breathing and rose to 41.8% with Continuous Positive Airway Pressure (CPAP) 5 cmH2O; by contrast, controlled mechanical ventilation showed lower leakage, with the smallest values at Peak Inspiratory Pressure (PIP) of 12 cmH2O and 16 cmH2O (2.1% and 6.5%, respectively). Re-used devices leaked less than new ones (p = 0.003). Placement by students was straightforward after adequate depth was achieved. Complications included mild regurgitant material in three cats and pulmonary aspiration in two (one euthanised, one discharged after supportive care). The V-gel® advanced enabled rapid airway management with leakage influenced by ventilation mode, airway pressure, and device re-use. Findings support cautious use during spontaneous breathing or CPAP, attention to fasting and fresh-gas flows, and further controlled comparisons with prior V-gel® models and endotracheal intubation.
- 22 November 2025
- Published by MDPI AG in Veterinary Sciences
- Vol. 12 (12) , 1112
Open AccessEvaluation of the V-gel® Advanced Supraglottic Airway Device Across Different Ventilatory Modes in Anaesthetised Cats
Endotracheal intubation in cats carries risks; supraglottic airway devices (SADs) offer a less invasive alternative. This prospective clinical study evaluated the V-gel® advanced in cats undergoing ovariohysterectomy, with the primary aim of intra-anaesthetic gas leakage; secondary aims were ease of placement, complications, and the effect of device re-use. Spirometric inspired/expired tidal volumes were recorded under predefined ventilatory settings; leakage was calculated and analysed. Of 52 cats enrolled, 47 were analysed. Leakage occurred in 13% during spontaneous breathing and rose to 41.8% with Continuous Positive Airway Pressure (CPAP) 5 cmH2O; by contrast, controlled mechanical ventilation showed lower leakage, with the smallest values at Peak Inspiratory Pressure (PIP) of 12 cmH2O and 16 cmH2O (2.1% and 6.5%, respectively). Re-used devices leaked less than new ones (p = 0.003). Placement by students was straightforward after adequate depth was achieved. Complications included mild regurgitant material in three cats and pulmonary aspiration in two (one euthanised, one discharged after supportive care). The V-gel® advanced enabled rapid airway management with leakage influenced by ventilation mode, airway pressure, and device re-use. Findings support cautious use during spontaneous breathing or CPAP, attention to fasting and fresh-gas flows, and further controlled comparisons with prior V-gel® models and endotracheal intubation.