Stefano Loreti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stefano Loreti has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
- Mario Pillon
ENEA Department of Fusion and Technologies for Nuclear Safety and Security, Via Enrico Fermi 45, I, 00044 Frascati (Roma), Italy
3 shared publications - Chantal Nobs
Applied Radiation Technology, CCFE, Abingdon, Oxfordshire, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
2 shared publications - Davide Rigamonti
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
2 shared publications - Enrico Perelli Cippo
Institute for Plasma Science and Technology, National Research Council 2 , Milan 20125
2 shared publications - Erik Gallo
Eni S.p.A, Piazzale Mattei 1, 00144 Roma, Italy
2 shared publications - Lee William Packer
United Kingdom Atomic Energy Authority
2 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (10) , 105028
Shutdown dose rate measurements with Ionization Chambers during and at the end of DT operations at JET
Within the framework of EUROfusion’s technological exploitation of deuterium–tritium (DT) operation at JET—initiated under work package JET3 and continued under PrIO—the NEXP sub-project was conceived to exploit the substantial neutron yield expected during the DT campaigns (DTE2 and DTE3) to validate the numerical tools employed for neutron streaming and shutdown dose rate (SDDR) prediction in ITER. This validation, grounded in direct comparison between computational predictions and experimental measurements, constitutes a critical step in demonstrating the reliability of the SDDR methodology that underpins ITER’s radiation safety case. As part of this activity, a dedicated dosimetry system based on spherical air-vented ionization chambers was installed in the JET Torus Hall in 2015 and has since undergone successive hardware and software upgrades to address operational challenges identified across DT experimental campaigns. This work traces the evolution of the SDDR dosimetry system and presents the analysis of the measurements acquired during the DT operation of JET, in particular the third DT campaign (DTE3) and, uniquely, throughout the ongoing final shutdown, a phase offering measurement conditions unlikely to be replicated elsewhere. SDDR predictions with the Advanced D1S tool by ENEA are described as well.
- 1 October 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (10) , 105028
Open AccessShutdown dose rate measurements with Ionization Chambers during and at the end of DT operations at JET
Within the framework of EUROfusion’s technological exploitation of deuterium–tritium (DT) operation at JET—initiated under work package JET3 and continued under PrIO—the NEXP sub-project was conceived to exploit the substantial neutron yield expected during the DT campaigns (DTE2 and DTE3) to validate the numerical tools employed for neutron streaming and shutdown dose rate (SDDR) prediction in ITER. This validation, grounded in direct comparison between computational predictions and experimental measurements, constitutes a critical step in demonstrating the reliability of the SDDR methodology that underpins ITER’s radiation safety case. As part of this activity, a dedicated dosimetry system based on spherical air-vented ionization chambers was installed in the JET Torus Hall in 2015 and has since undergone successive hardware and software upgrades to address operational challenges identified across DT experimental campaigns. This work traces the evolution of the SDDR dosimetry system and presents the analysis of the measurements acquired during the DT operation of JET, in particular the third DT campaign (DTE3) and, uniquely, throughout the ongoing final shutdown, a phase offering measurement conditions unlikely to be replicated elsewhere. SDDR predictions with the Advanced D1S tool by ENEA are described as well.
- Open Access
- 31 March 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (4)
SiC Neutron Detectors: Enhancing the Dynamic Range through Partial Depletion Operation
Silicon carbide (SiC) detectors are promising candidates for neutron diagnostics in fusion environments, where instruments must endure intense neutron and gamma fluxes, high temperatures, and restricted accessibility. Partial depletion operation enables online control of detector efficiency by varying the applied bias voltage, thereby tuning the response to adapt to the widely changing neutron fluxes expected in future tokamak experiments. In this work, the functionality of two 4H-SiC detectors with different thicknesses (100 μm and 250 μm) is investigated under partial depletion conditions. Measurements are performed with 2.5 MeV and 14 MeV neutrons produced at the Frascati Neutron Generator and benchmarked against Geant4 simulations. Results show that detector efficiency can be predictably controlled within a factor of five without degrading energy resolution. Full depletion in the 100 μm device was reached at lower voltages than expected, possibly due to doping variations or irradiation effects. These findings confirm the potential of partial depletion as a tool for real-time tuning of SiC detector response, with significant implications for neutron diagnostics in future fusion reactors.
- 31 March 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 68 (4)
Open AccessSiC Neutron Detectors: Enhancing the Dynamic Range through Partial Depletion Operation
Silicon carbide (SiC) detectors are promising candidates for neutron diagnostics in fusion environments, where instruments must endure intense neutron and gamma fluxes, high temperatures, and restricted accessibility. Partial depletion operation enables online control of detector efficiency by varying the applied bias voltage, thereby tuning the response to adapt to the widely changing neutron fluxes expected in future tokamak experiments. In this work, the functionality of two 4H-SiC detectors with different thicknesses (100 μm and 250 μm) is investigated under partial depletion conditions. Measurements are performed with 2.5 MeV and 14 MeV neutrons produced at the Frascati Neutron Generator and benchmarked against Geant4 simulations. Results show that detector efficiency can be predictably controlled within a factor of five without degrading energy resolution. Full depletion in the 100 μm device was reached at lower voltages than expected, possibly due to doping variations or irradiation effects. These findings confirm the potential of partial depletion as a tool for real-time tuning of SiC detector response, with significant implications for neutron diagnostics in future fusion reactors.
- Open Access
- 3 March 2026
- Published by Elsevier in SSRN Electronic Journal
Development of Neutron Attenuators for Gamma Ray Measurements in DT fusion experiments
The gamma rays emitted by the T(D,γ)5He fusion reaction have been measured at the FNG neutron irradiation facility in ENEA-Frascati by using a large 3”x3” LaBr3 scintillator crystal. Since the gamma ray emission probability by the DT reaction is 10-5 lower with respect to the main fusion reaction channel T(D,n)4He a neutron attenuator is needed. In this paper we present the design of a neutron attenuator based on a combination of different materials. The neutron attenuator performances have been studied with a series of MCNP simulations benchmarked with an experiment performed with a 137Cs gamma ray source. The analysis of the experimental results shows a gamma component in the region of interest that is compatible with the T(D,γ)5He reaction. Although the results obtained at FNG indicate that the gamma rays emitted by the T(D,γ)5He can be measured with the present set-up, they also show that an improvement of the experimental set-up is needed. An analysis of the background induced by the scattered neutrons is provided and improvements to the neutron attenuator are proposed.
- 3 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment of Neutron Attenuators for Gamma Ray Measurements in DT fusion experiments
The gamma rays emitted by the T(D,γ)5He fusion reaction have been measured at the FNG neutron irradiation facility in ENEA-Frascati by using a large 3”x3” LaBr3 scintillator crystal. Since the gamma ray emission probability by the DT reaction is 10-5 lower with respect to the main fusion reaction channel T(D,n)4He a neutron attenuator is needed. In this paper we present the design of a neutron attenuator based on a combination of different materials. The neutron attenuator performances have been studied with a series of MCNP simulations benchmarked with an experiment performed with a 137Cs gamma ray source. The analysis of the experimental results shows a gamma component in the region of interest that is compatible with the T(D,γ)5He reaction. Although the results obtained at FNG indicate that the gamma rays emitted by the T(D,γ)5He can be measured with the present set-up, they also show that an improvement of the experimental set-up is needed. An analysis of the background induced by the scattered neutrons is provided and improvements to the neutron attenuator are proposed.
- Open Access
- 22 February 2021
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 247, 09011
A COMPARISON OF OXIDE DECAY HEAT SIMULATIONS AND NUCLEAR DATA LIBRARIES WITH FUSION IRRADIATION EXPERIMENTS
We compare existing experimental decay heat data sets measured at the JAEA fusion neutron source (FNS), which employed a fast extraction rabbit system that in certain cases allowed the measurements to capture, at short cooling times, the decay profile of 16N in a range of oxides. Focussing on those data points and timescales that can be attributed to 16N, we compare measurements to simulations performed using the FISPACT-II inventory code together with evaluated nuclear data libraries. Making small corrections for other contributions at these short times, we derive integral cross section data estimates for 16O(n,p)16N from 12 oxide sample measurements and compare with previously obtained measurements in the IAEA EXFOR database and evaluations in the nuclear data libraries themselves.
- 22 February 2021
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 247, 09011
Open AccessA COMPARISON OF OXIDE DECAY HEAT SIMULATIONS AND NUCLEAR DATA LIBRARIES WITH FUSION IRRADIATION EXPERIMENTS
We compare existing experimental decay heat data sets measured at the JAEA fusion neutron source (FNS), which employed a fast extraction rabbit system that in certain cases allowed the measurements to capture, at short cooling times, the decay profile of 16N in a range of oxides. Focussing on those data points and timescales that can be attributed to 16N, we compare measurements to simulations performed using the FISPACT-II inventory code together with evaluated nuclear data libraries. Making small corrections for other contributions at these short times, we derive integral cross section data estimates for 16O(n,p)16N from 12 oxide sample measurements and compare with previously obtained measurements in the IAEA EXFOR database and evaluations in the nuclear data libraries themselves.
- 1 September 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 146, 2658-2662
Neutron spectrum unfolding for the development of a novel neutron detector for fusion
- 1 September 2019
- Published by Elsevier in Fusion Engineering and Design
- Vol. 146, 2658-2662
Neutron spectrum unfolding for the development of a novel neutron detector for fusion
- 1 April 1999
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 67-68, 181-186
Characterisation of Excimer Laser Crystallised Polysilicon by X-Ray Diffraction and by Channeling Contrast in a Scanning Electron Microscope
- 1 April 1999
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 67-68, 181-186
Characterisation of Excimer Laser Crystallised Polysilicon by X-Ray Diffraction and by Channeling Contrast in a Scanning Electron Microscope