Lam Hoang Hao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lam Hoang Hao has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Tran Duy Tap
Faculty of Materials Science and Technology University of Science Ho Chi Minh City Vietnam
2 shared publications Dang Van Hoa
• Faculty of Materials Science and Technology, University of Science, 227 Nguyen Van Cu, District 5, Ho Chi Minh, Viet Nam • Viet Nam National University, Ho Chi Minh, Viet Nam
1 shared publication- Dinh Tran Trong Hieu
Faculty of Materials Science and Technology University of Science Ho Chi Minh City Vietnam
1 shared publication Hoang Long Tran
Faculty of Materials Science and Technology, University of Science, Ho Chi Minh City, 227 Nguyen Van Cu, District 5, Ho Chi Minh City, Viet Nam
1 shared publication- Hong Thi Pham
School of Environmental Science and Technology, Hanoi University of Science and Technology, Hanoi, Vietnam
1 shared publication Huynh My Tue Nguyen
Faculty of Materials Science and Technology, University of Science, Ho Chi Minh City, 227 Nguyen Van Cu, District 5, Ho Chi Minh City, Viet Nam
1 shared publication
Latest Publications
- Open Access
- 1 January 2023
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 26 (4) , 3060-3068
Effects of source correction on positron annihilation lifetime spectroscopic analysis of graft-type polymer electrolyte membranes
Introduction: Recently, the free-volume hole features of poly(styrene sulfonic acid) (PSSA)-grafted poly(ethylene-co-tetrafluoroethylene) polymer electrolyte membranes (ETFE-PEMs) have been studied using positron annihilation lifetime spectroscopy (PALS) to determine the relationship between gas crossover through a PEM and a fuel cell. As one such series, this work investigates the source correction in PAL spectroscopic analysis for ETFE-PEM. Method: ETFE-PEM was prepared by radiation-induced graft polymerization and subsequent sulfonation. The free-volume hole characteristics of ETFE-PEM with a grafting degree (GD) of 106% were determined using PALS with and without source correction. Results: After source correction, the original-ETFE and ETFE-PEM strains exhibited increases in r3 (smaller radius of free-volume holes in the lamellar amorphous regions, the PSSA grafts, and the interface zones inside the lamellae) and r4 (larger radius of free-volume holes in the mobile amorphous layers and the PSSA grafts outside of the lamellae). In addition, the full width at half maximum (FWHM) of r3 is much greater than that of r4 due to the rearrangement in the mobile amorphous region and the polystyrene layers outside the lamellar structure. Conclusion: Source correction causes a significant change in the distribution curves of r3 for the original-ETFE and ETFE-PEM. Thus, source correction of positron annihilation lifetime spectroscopic analyses is an important issue for determining the o-Ps lifetime of polymers, which is near the lifetime of positrons in source materials.
- 1 January 2023
- Published by Viet Nam National University Ho Chi Minh City in Journal of Science and Technology Development
- Vol. 26 (4) , 3060-3068
Open AccessEffects of source correction on positron annihilation lifetime spectroscopic analysis of graft-type polymer electrolyte membranes
Introduction: Recently, the free-volume hole features of poly(styrene sulfonic acid) (PSSA)-grafted poly(ethylene-co-tetrafluoroethylene) polymer electrolyte membranes (ETFE-PEMs) have been studied using positron annihilation lifetime spectroscopy (PALS) to determine the relationship between gas crossover through a PEM and a fuel cell. As one such series, this work investigates the source correction in PAL spectroscopic analysis for ETFE-PEM. Method: ETFE-PEM was prepared by radiation-induced graft polymerization and subsequent sulfonation. The free-volume hole characteristics of ETFE-PEM with a grafting degree (GD) of 106% were determined using PALS with and without source correction. Results: After source correction, the original-ETFE and ETFE-PEM strains exhibited increases in r3 (smaller radius of free-volume holes in the lamellar amorphous regions, the PSSA grafts, and the interface zones inside the lamellae) and r4 (larger radius of free-volume holes in the mobile amorphous layers and the PSSA grafts outside of the lamellae). In addition, the full width at half maximum (FWHM) of r3 is much greater than that of r4 due to the rearrangement in the mobile amorphous region and the polystyrene layers outside the lamellar structure. Conclusion: Source correction causes a significant change in the distribution curves of r3 for the original-ETFE and ETFE-PEM. Thus, source correction of positron annihilation lifetime spectroscopic analyses is an important issue for determining the o-Ps lifetime of polymers, which is near the lifetime of positrons in source materials.
- Open Access
- 16 September 2021
- Published by Vietnam National University Journal of Science in VNU Journal of Science: Natural Sciences and Technology
Investigation of the Lamellar Grains of Graft-type Polymer Electrolyte Membranes for Hydrogen Fuel Cell Application using Ultrasmall-angle X-ray Scattering
The extensive ultrasmall-angle X-ray scattering measurements are performed in order to investigate the changes of lamellar grains of poly(styrenesulfonic acid)-grafted poly(ethylene-co-tetrafluoroethylene) polymer electrolyte membranes (ETFE-PEMs) that occur during the alteration of grafting degree (GD) under dry and immersed conditions. The lamellar grains of three series of the samples (polystyrene-grafted ETFE films and dry and hydrated ETFE-PEMs) are formed during the grafting process and develop independently with the change of the lamellar stacks. Interestingly, three series of samples exhibit a very similar trend of lamellar grain at any GD and a significant amount of graft chains is observed directly in the region between the grains (GD £ 59%) and outside of the grain network structures (GD > 59%). This observation indicates: i) The formation of the lamellar grains; ii) The rapid changes in characteristic sizes of the lamellar grains compared with the lamellar stacks; and iii) The newly generated phases consisting of only the graft materials. These findings explain why the lamellar grains and the graft chains play an important role in the higher proton conductivity and compatible tensile strengths of the membranes, compared with Nafion, at the immersed and severe operating conditions.
- 16 September 2021
- Published by Vietnam National University Journal of Science in VNU Journal of Science: Natural Sciences and Technology
Open AccessInvestigation of the Lamellar Grains of Graft-type Polymer Electrolyte Membranes for Hydrogen Fuel Cell Application using Ultrasmall-angle X-ray Scattering
The extensive ultrasmall-angle X-ray scattering measurements are performed in order to investigate the changes of lamellar grains of poly(styrenesulfonic acid)-grafted poly(ethylene-co-tetrafluoroethylene) polymer electrolyte membranes (ETFE-PEMs) that occur during the alteration of grafting degree (GD) under dry and immersed conditions. The lamellar grains of three series of the samples (polystyrene-grafted ETFE films and dry and hydrated ETFE-PEMs) are formed during the grafting process and develop independently with the change of the lamellar stacks. Interestingly, three series of samples exhibit a very similar trend of lamellar grain at any GD and a significant amount of graft chains is observed directly in the region between the grains (GD £ 59%) and outside of the grain network structures (GD > 59%). This observation indicates: i) The formation of the lamellar grains; ii) The rapid changes in characteristic sizes of the lamellar grains compared with the lamellar stacks; and iii) The newly generated phases consisting of only the graft materials. These findings explain why the lamellar grains and the graft chains play an important role in the higher proton conductivity and compatible tensile strengths of the membranes, compared with Nafion, at the immersed and severe operating conditions.