Yu He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yu He has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- De-Wen Zhang
Xi’an Jiaotong University
1 shared publication Haiming Sun
Electric Power Research Institute of State Grid Heilongjiang Electric Power Company Limited, Harbin, China
1 shared publication- Hongyi Zhou
College of Electrical Engineering Southwest Jiaotong University Chengdu China
1 shared publication - Jian Zhang
State Key Laboratory of Structural Chemistry Fujian Institute of Research on the Structure of Matter Chinese Academy of Sciences Fuzhou Fujian China
1 shared publication Jianquan Liang
Electric Power Research Institute of State Grid Heilongjiang Electric Power Company Limited, Harbin, China
1 shared publication- Li Lin
Purdue University, West Lafayette, IN, USA
1 shared publication
Latest Publications
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1614-1619
A Quantification Method of Harmonic Responsibilities Based on Current Tracing Principle
A responsibility judgment of harmonic sources to loads in power systems is necessary for establishing economic reward and punishment mechanisms. Existing harmonic responsibility quantification methods mainly analyze the responsibility distribution between the user side and the grid side at the point of common coupling (PCC). The contributions of harmonic sources to each bus and branch cannot be quantified in power networks. This paper proposes a harmonic responsibility apportion method that can quantitatively analyze responsibility shares of harmonic sources in the whole power network. The current tracing principle is applied to establish the harmonic responsibility apportion model that represents the influence degree of harmonic sources. The harmonic current data of the entire network is substituted into the apportion model to obtain responsibility shares of harmonic sources at each bus and branch. The contribution of filters on harmonic suppression is analyzed based on the apportion model. Case studies on an IEEE 9-bus system are conducted to verify the effectiveness of the method.
- 1 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1614-1619
A Quantification Method of Harmonic Responsibilities Based on Current Tracing Principle
A responsibility judgment of harmonic sources to loads in power systems is necessary for establishing economic reward and punishment mechanisms. Existing harmonic responsibility quantification methods mainly analyze the responsibility distribution between the user side and the grid side at the point of common coupling (PCC). The contributions of harmonic sources to each bus and branch cannot be quantified in power networks. This paper proposes a harmonic responsibility apportion method that can quantitatively analyze responsibility shares of harmonic sources in the whole power network. The current tracing principle is applied to establish the harmonic responsibility apportion model that represents the influence degree of harmonic sources. The harmonic current data of the entire network is substituted into the apportion model to obtain responsibility shares of harmonic sources at each bus and branch. The contribution of filters on harmonic suppression is analyzed based on the apportion model. Case studies on an IEEE 9-bus system are conducted to verify the effectiveness of the method.