A. S. M. Jahid Hasan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
A. S. M. Jahid Hasan has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Jubair Yusuf
Sandia National Laboratories, Albuquerque, NM, USA
4 shared publications Sadrul Ula
University of California Riverside
3 shared publications- Luis Fernando Enriquez-Contreras
Department of Electrical and Computer Engineering, University of California, Riverside, CA
2 shared publications Farhana Akter Tumpa
Ahsanullah University of Science and Technology,Dhaka,Bangladesh
1 shared publication- Jacqueline Garrido
Department of Electrical Engineering, University of Colorado Denver, Denver, CO 80204, USA
1 shared publication Matthew J. Barth
University of California Riverside
1 shared publication
Latest Publications
- Open Access
- 3 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Location Agnostic Source-Free Domain Adaptive Learning to Predict Solar Power Generation
The prediction of solar power generation is a challenging task due to its dependence on climatic characteristics that exhibit spatial and temporal variability. The performance of a prediction model may vary across different places due to changes in data distribution, resulting in a model that works well in one region but not in others. Furthermore, as a consequence of global warming, there is a notable acceleration in the alteration of weather patterns on an annual basis. This phenomenon introduces the potential for diminished efficacy of existing models, even within the same geographical region, as time progresses. In this paper, a domain adaptive deep learning-based framework is proposed to estimate solar power generation using weather features that can solve the aforementioned challenges. A feed-forward deep convolutional network model is trained for a known location dataset in a supervised manner and utilized to predict the solar power of an unknown location later. This adaptive data-driven approach exhibits notable advantages in terms of computing speed, storage efficiency, and its ability to improve outcomes in scenarios where state-of-the-art non-adaptive methods fail. Our method has shown an improvement of 10.47%, 7.44%, 5.11% in solar power prediction accuracy compared to best performing non-adaptive method for California (CA), Florida (FL) and New York (NY), respectively.
- 3 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Open AccessLocation Agnostic Source-Free Domain Adaptive Learning to Predict Solar Power Generation
The prediction of solar power generation is a challenging task due to its dependence on climatic characteristics that exhibit spatial and temporal variability. The performance of a prediction model may vary across different places due to changes in data distribution, resulting in a model that works well in one region but not in others. Furthermore, as a consequence of global warming, there is a notable acceleration in the alteration of weather patterns on an annual basis. This phenomenon introduces the potential for diminished efficacy of existing models, even within the same geographical region, as time progresses. In this paper, a domain adaptive deep learning-based framework is proposed to estimate solar power generation using weather features that can solve the aforementioned challenges. A feed-forward deep convolutional network model is trained for a known location dataset in a supervised manner and utilized to predict the solar power of an unknown location later. This adaptive data-driven approach exhibits notable advantages in terms of computing speed, storage efficiency, and its ability to improve outcomes in scenarios where state-of-the-art non-adaptive methods fail. Our method has shown an improvement of 10.47%, 7.44%, 5.11% in solar power prediction accuracy compared to best performing non-adaptive method for California (CA), Florida (FL) and New York (NY), respectively.
- Open Access
- 15 June 2022
- Published by Elsevier in SSRN Electronic Journal
A Comparative Techno-Economic Assessment of Bidirectional Heavy Duty and Light Duty Plug-In Electric Vehicles Operation: A Case Study
The proliferation of electric vehicles all around the world offers both challenges and opportunities. Bidirectional charging capabilities at workplace charging facilities (e.g., as part of a microgrid) have now made the overall economic optimization more attractive, but also more complex. This paper investigates the cost optimization problem for bidirectional charging at a workplace microgrid with the goal of determining the optimal framework for a combination of both heavy-duty and light-duty electric vehicles (HDEV and LDEV). A deep learning-based model has been developed to forecast the 15-minute solar generation and building power consumption. Real-time travel profile data is used to represent the temporal uncertainty of electric vehicle charging. The cost optimization problem is formulated as a Mixed Integer Programming (MIP) model which also addresses battery life degradation. Further, a comprehensive cost-benefit analysis has been carried out to analyze the payback period, peak reduction, and cost savings for two different buildings at the same workplace with both on-board and off-board charger configurations. It has been found that HDEVs are a better cost-effective solution in comparison to LDEVs in terms of energy cost reduction and payback periods. Net metering capability leads to higher energy savings and peak reductions in most cases
- 15 June 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Comparative Techno-Economic Assessment of Bidirectional Heavy Duty and Light Duty Plug-In Electric Vehicles Operation: A Case Study
The proliferation of electric vehicles all around the world offers both challenges and opportunities. Bidirectional charging capabilities at workplace charging facilities (e.g., as part of a microgrid) have now made the overall economic optimization more attractive, but also more complex. This paper investigates the cost optimization problem for bidirectional charging at a workplace microgrid with the goal of determining the optimal framework for a combination of both heavy-duty and light-duty electric vehicles (HDEV and LDEV). A deep learning-based model has been developed to forecast the 15-minute solar generation and building power consumption. Real-time travel profile data is used to represent the temporal uncertainty of electric vehicle charging. The cost optimization problem is formulated as a Mixed Integer Programming (MIP) model which also addresses battery life degradation. Further, a comprehensive cost-benefit analysis has been carried out to analyze the payback period, peak reduction, and cost savings for two different buildings at the same workplace with both on-board and off-board charger configurations. It has been found that HDEVs are a better cost-effective solution in comparison to LDEVs in terms of energy cost reduction and payback periods. Net metering capability leads to higher energy savings and peak reductions in most cases
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
A Centralized Optimization Approach for Bidirectional Pev Strategy Selection in a Commercial Building-Integrated Microgrid
Building sector is the largest energy user in the United States. Conventional building energy studies mostly involve Heating, Ventilation, and Air Conditioning (HVAC), and lighting energy consumptions. Recent additions of solar Photovoltaics (PV) along with other Distributed Energy Resources (DER), particularly Plug-in Electric Vehicles (PEV) have added a new dimension to this problem and made it more complex. An avant-garde framework is proposed for selecting the best charging/discharging level of PEV for a commercial building-integrated microgrid in this paper. A typical commercial building is used as a microgrid testbed incorporating all the DERs presented in a smart building. A Mixed Integer Linear Programming (MILP) problem is formulated to optimize the energy and demand cost associated with this building operation. The cost function is solved in conjunction with real data and modified to assess the bidirectional PEV impacts on the flexible building loads that are contributing factors in making energy usage decisions. Finally, the impacts of optimized DERs are investigated on a Distribution System (DS) to show the necessity of a holistic approach for selecting the suitable PEV strategies. The results show that bidirectional fast PEV activities can provide higher cost reduction and less voltage deviation in comparison to slow PEV activities.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Centralized Optimization Approach for Bidirectional Pev Strategy Selection in a Commercial Building-Integrated Microgrid
Building sector is the largest energy user in the United States. Conventional building energy studies mostly involve Heating, Ventilation, and Air Conditioning (HVAC), and lighting energy consumptions. Recent additions of solar Photovoltaics (PV) along with other Distributed Energy Resources (DER), particularly Plug-in Electric Vehicles (PEV) have added a new dimension to this problem and made it more complex. An avant-garde framework is proposed for selecting the best charging/discharging level of PEV for a commercial building-integrated microgrid in this paper. A typical commercial building is used as a microgrid testbed incorporating all the DERs presented in a smart building. A Mixed Integer Linear Programming (MILP) problem is formulated to optimize the energy and demand cost associated with this building operation. The cost function is solved in conjunction with real data and modified to assess the bidirectional PEV impacts on the flexible building loads that are contributing factors in making energy usage decisions. Finally, the impacts of optimized DERs are investigated on a Distribution System (DS) to show the necessity of a holistic approach for selecting the suitable PEV strategies. The results show that bidirectional fast PEV activities can provide higher cost reduction and less voltage deviation in comparison to slow PEV activities.
- 18 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 01-05
Bad Cell Identification of Utility-Scale Battery Energy Storage System through Statistical Analysis of Electrical and Thermal Properties
High penetration of renewable integration with the grid has invoked the necessity for battery energy storage applications. This has been further escalated by technology advances and descending costs. Utility-Scale Battery Energy Storage Systems (BESS) are being deployed worldwide in numerous projects due to their ability to provide grid ancillary services such as frequency regulation, flexible ramping, and black start services besides their energy storing and shifting capabilities. To ensure reliable and safe operation, identifying the bad battery cells in a Utility-Scale BESS is of profound importance. This paper proposes a comprehensible method of bad cell identification for Utility-Scale BESS by evaluating the necessary electrical and thermal properties of the cells through statistical approaches. This method only requires data that is easily available and accessible and can save a lot of time and effort. A detailed formulation of the analysis process was carried out and applied to data from a Utility-Scale BESS. Results demonstrated that the method can successfully identify bad cells in a BESS containing a large number of cells. This approach can offer prospective economic benefits by reducing the Operation and Maintenance (O&M) costs associated with Utility-Scale BESS.
- 18 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 01-05
Bad Cell Identification of Utility-Scale Battery Energy Storage System through Statistical Analysis of Electrical and Thermal Properties
High penetration of renewable integration with the grid has invoked the necessity for battery energy storage applications. This has been further escalated by technology advances and descending costs. Utility-Scale Battery Energy Storage Systems (BESS) are being deployed worldwide in numerous projects due to their ability to provide grid ancillary services such as frequency regulation, flexible ramping, and black start services besides their energy storing and shifting capabilities. To ensure reliable and safe operation, identifying the bad battery cells in a Utility-Scale BESS is of profound importance. This paper proposes a comprehensible method of bad cell identification for Utility-Scale BESS by evaluating the necessary electrical and thermal properties of the cells through statistical approaches. This method only requires data that is easily available and accessible and can save a lot of time and effort. A detailed formulation of the analysis process was carried out and applied to data from a Utility-Scale BESS. Results demonstrated that the method can successfully identify bad cells in a BESS containing a large number of cells. This approach can offer prospective economic benefits by reducing the Operation and Maintenance (O&M) costs associated with Utility-Scale BESS.