BTBin Tang

Bin Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bin Tang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • Chongxi Xu

    Department of Emergency Medicine, State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China

    1 shared publication
  • Gong Suijun

    Nuclear Power Institute of China, Chengdu, Sichuan, 610213, China

    1 shared publication
  • Junpeng Ma

    Department of Polymer Science and Engineering, MOE Key Laboratory of High Performance Polymer Materials and Technology, School of Chemistry and Chemical Engineering, Nanjing University 1 , Nanjing 210023, China

    1 shared publication
  • Lei Zhou

    State Key Laboratory of Engines, School of Mechanical Engineering, Tianjin University, Tianjin, 300072, China

    1 shared publication
  • Renming Zhong

    1 shared publication
  • Si-Qing Huang

    Department of Neurosurgery, West China Hospital, Sichuan University, Chengdu 610041, China

    1 shared publication

Latest Publications

  • Numerical investigation on the electrohydrodynamic evolution in stretchable micropumps based on lattice Boltzmann method

    by Bin Tang, Renming Zhong, Yuehu Pu

    The electrohydrodynamic behavior of stretchable interdigitated micropumps under transient operating conditions remains poorly understood. This study presents the first high-fidelity lattice Boltzmann simulation of a negatively charge-injected stretchable micropump with realistic geometry. The model accurately reproduced experimental hydrostatic pressure and hydrodynamic flow rates, while resolving previously inaccessible microsecond-scale dynamics. Key findings revealed that the micropump exhibited strong sub-millisecond flow reversals during startup under free-flow conditions, with oscillation amplitudes significantly exceeding steady-state values. These transients can be effectively suppressed by pre-establishing charge distribution before valve actuation. Furthermore, we have identified and explained the “charge-filtered effect” responsible for the emergence and upstream migration of charge voids, which governs vortex restructuring and leads to complex multi-vortex flow patterns. This work provides a validated computational framework for designing soft electrohydrodynamic devices in applications ranging from flexible robotics to implantable medical systems.


  • [Three-Dimensional Nonlinear Finite Element Modeling and Analysis of Concomitant Atlanto-Occipital Fusion and Atlantoaxial Joint Dislocation].

    by Chong-Xi Xu, Bin Tang, Xi-Hang Zeng, Si-Qing Huang, Jun-Peng Ma

    To establish, with finite element technology, a three-dimensional nonlinear finite element model of the normal occipital bone, atlas and axis and a three-dimensional nonlinear finite element model of concomitant atlanto-occipital fusion and atlantoaxial dislocation, providing a biomechanical method for clinical research on the upper cervical spine. Finite element analysis was conducted with the CT data of a 27-year-old male volunteer, and a three-dimensional nonlinear finite element model, i.e., the normal model, of the normal occipital bone, atlas and axis was established accordingly. Finite element analysis was conducted with the CT data of a 35-year-old male patient with concomitant atlanto-occipital fusion and atlantoaxial dislocation. Then, the ideal state of a simple ligament rupture under high load was generated by computer simulation, and a three-dimensional nonlinear finite element model of concomitant atlanto-occipital fusion and atlantoaxial dislocation was established, i.e., the atlanto-occipital fusion with atlantoaxial dislocation model. For both models, a vertical upward torque of 1.5 N·m was applied on the upper surface of the occipital bone. Through comparative analysis of the two models under stress, the data of the range of motion (ROM) for flexion, extension, lateral bending, and rotation were examined. In addition, stress and deformation analysis with 1.5 N·m torque load was conducted to validate the effectiveness of the two three-dimensional nonlinear finite element models established in the study. When the normal model established in the study was under 1.5 N·m torque load, it exhibited a maximum ROM for each unit of flexion, extension, and the ROM approximated the experimental measurement results of human mechanics, confirming the validity of the simulation. The stress and deformation results of the model were consistent with the basic principles of mechanics. The moment-angular displacement of the model showed obvious nonlinear characteristics. Compared with the normal model, the atlanto-occipital fusion with atlantoaxial dislocation model showed reduced ROM of the atlanto-occipital joint under a torque of 1.5 N·m, while the ROM of the C1-C2 joint for the four conditions of flexion, posterior extention, lateral bending, and rotation under load, with the exception of rotating motion, was greatly increased compared with that of the normal model, which was in line with the actual clinical performance of the patient. The atlanto-occipital fusion with atlantoaxial dislocation model and the three-dimensional nonlinear finite element model of the normal occipital bone, atlas and axis were successfully established by finite element technology. The models had valid simulation and reliable kinematic characteristics, and could be used as a reliable tool to simulate clinical diseases.