CKChristian Keller

Christian Keller

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christian Keller has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A comparison of face-to-face, brochure- and video-assisted anesthesia interviews: a qualitative randomized survey study

    by Berthold Moser, Tamara Nold, Lukas Gasteiger, Vanessa Moll, Christian Keller, Winfried Zinn

    Article: A comparison of face-to-face, brochure- and video-assisted anesthesia interviews: a qualitative randomized survey study - Minerva Anestesiologica 2022 Jan 24 - Minerva Medica - Journals


  • Breathing-motion-compensated robotic guided stereotactic body radiation therapy

    by Susanne Stera, Panagiotis Balermpas, Mark K. H. Chan, Stefan Huttenlocher, Stefan Wurster, Christian Keller, Detlef Imhoff, Dirk Rades, Jürgen Dunst, Claus Rödel, et al.

    We retrospectively evaluated the patterns of failure for robotic guided real-time breathing-motion-compensated (BMC) stereotactic body radiation therapy (SBRT) in the treatment of tumors in moving organs.


  • Head-position angles in children for opening the upper airway

    by Peter Paal, Thomas Niederklapfer, Christian Keller, Achim von Goedecke, Günter Luckner, Daniel Pehboeck, Thomas Mitterlechner, Holger Herff, Ursula Riccabona, Volker Wenzel


  • Lachgasbedingte Todesfälle

    by H. Herff, P. Paal, K.H. Lindner, A. von Goedecke, C. Keller, V. Wenzel

    Trotz gesetzlicher Vorschriften in der europäischen Norm EN 740 zur Verwendung von Messgeräten der inspiratorischen Sauerstofffraktion (FIO2-Meter) treten Todesfälle durch fälschliche Beatmung mit reinem Lachgas häufiger auf als erwartet, insbesondere nach Bau- oder Reparaturmaßnahmen an den Gasleitungen. Sofern Lachgas weiter in einer Klinik verwendet werden soll, sollten daher alle technischen und logistischen Schutzmaßnahmen zur Prävention von Zwischenfällen ergriffen werden. Dazu gehört neben einer Messung der inspiratorischen Sauerstoffkonzentration eine automatische Lachgasbeschränkung. Hinzu kommt die genaue Information der beteiligten Anästhesisten über etwaige Umbaumaßnahmen. Zudem muss das Bewusstsein für die Lachgasproblematik geschärft werden. Außerdem gilt es die Sicherheitssysteme weiterzuentwickeln, damit Lachgaskomplikationen sowohl in einer Klinik als auch landesweit besser erfasst und analysiert werden können. Dies könnte neben besserer Vernetzung der Fehlererfassungssysteme und Rückgriff auf Datenbanken der Versicherungen nach Haftpflichtprozessen auch den direkten Einbezug von Experten in die Unfallaufklärung beinhalten. Despite inspiratory oxygen fraction measurement being regulated by law in the European norm EN 740, fatal errors in nitrous oxide delivery still occur more frequently than expected, especially after construction or repair of gas connection tubes. Therefore, if nitrous oxide is to be used further in a hospital, all technical measures and system procedures should be employed to avoid future catastrophes. Among these are measurement of the inspiratory oxygen fraction (FIO2) and an automatic limitation of nitrous oxide. Also all anaesthetists involved should be informed about repair or construction of central gas supply tubes. Additionally, more awareness of this problem in daily routine is necessary. Furthermore, a system of detecting and analysing errors in anaesthesia has to be improved in each hospital as well as in the anaesthesia community as a whole. Measures for a better „error culture” could include data exchange between different critical incident reporting systems, analysis of closed claims, and integration of medical experts in examination of recent catastrophes.


  • Airway protection with the ProSealTM laryngeal mask airway in a child

    by Christian Keller, Joseph Brimacombe, Achim Goedecke, Philipp Lirk

    We describe a case where a size 2 ProSeal laryngeal mask airway successfully channelled regurgitated fluid away from the respiratory tract in a 5-year-old child following an inguinal hernia repair.


  • Open Access

    Is It Unethical to Use the Combitube in Elective Surgery Patients?

    by Joseph R. Brimacombe, Christian Keller

  • Coherence and decoherence in de Broglie interference of fullerenes

    by M. Arndt, O. Nairz, J. Petschinka, J. Voss-Andreae, G. van der Zouw, C. Keller, A. Zeilinger

    Summary form only given, as follows. In a recent experiment we were able to demonstrate the de Broglie wave character of the fullerene molecule C/sub 60/ by diffraction at a free standing material grating. This proves that it is possible to preserve quantum coherence almost completely in the external degrees of freedom of a hot, massive and complex object over a long time and distance. This may seem astonishing in the light of the fact that the fullerenes were produced in a thermal source which was kept at about 900 K. At such a high temperature the de Broglie wavelength is about 400 times smaller than the size of the molecule (/spl lambda//sub dB//spl sim/25 pm), all internal degrees of freedom (174 different vibrational modes, and rotational modes up to J>100) are excited and the molecules may emit a few infrared photons (blackbody radiation and vibrational quanta) during their time of flight through the apparatus. Our published measurements so far have been essentially consistent with the absence of decoherence during the time of flight of the molecules. The interference contrast in all experiments has however so far been limited by the thermal velocity spread and the finite collimation of the fullerene beam.


  • Open Access

    The cuffed oropharyngeal airway vs. the laryngeal mask airway: a randomised cross‐over study of oropharyngeal leak pressure and fibreoptic view in paralysed patients

    by J. Brimacombe, C. Keller

    We conducted a randomised cross‐over study of 20 patients to test the hypothesis that oropharyngeal leak pressure and the fibreoptic view differ between the cuffed oropharyngeal airway and laryngeal mask airway in paralysed patients. We also tested the design premise that inflation of the cuffed oropharyngeal airway cuff elevates the epiglottis from the posterior pharyngeal wall. Both airways were inserted into each patient in random order. Oropharyngeal leak pressure and fibreoptic view were documented at zero volume and after each additional 10 ml up to the maximum recommended volume for each device. The laryngeal mask had a higher maximum (23 vs. 16 cmH 2 O, p = 0.03), minimum (9 vs. 2 cmH 2 O, p < 0.02) and overall (17 vs. 9 cmH 2 O, p < 0.001) oropharyngeal leak pressure compared with the cuffed oropharyngeal airway. The glottic inlet was visible more frequently with the laryngeal mask (96 vs. 39%, p < 0.0001). There was no elevation of the epiglottis from the posterior pharyngeal wall with the cuffed oropharyngeal airway. We conclude that the laryngeal mask forms a more effective seal and provides a better fibreoptic view of the glottic inlet than the cuffed oropharyngeal airway in paralysed patients. Inflation of the cuffed oropharyngeal airway cuff does not cause elevation of the epiglottis.


  • Endotracheal Tube Safety During Electrodissection Tonsillectomy

    by Christopher Keller, Wallace Elliott, Richard N. Hubbell

    • A case report of an endotracheal tube fire occurring during electrodissection tonsillectomy is presented. The authors believe that this incident occurred because a retrograde leak of ventilating gases around an uncuffed endotracheal tube during positive-pressure ventilation produced a high oxygen concentration in the mouth, allowing indirect ignition of the tube. In vitro testing supported this hypothesis. Ignition tests on polyvinylchloride endotracheal tubes using electrocautery in various oxygen concentrations were performed. As oxygen concentration increased, the endotracheal tube could be moved further from the cautery and still allow ignition of the tube. At 52% oxygen, with the cautery set at 25-W coagulation current, the endotracheal tube could not be ignited. Recommendations to prevent a recurrence of this incident are included. (Arch Otolaryngol Head Neck Surg.1992;118:643-645)