Anastasios G. Skrivanos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anastasios G. Skrivanos has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ioannis Kouretas
Electrical and Computer Engineering Department, University of Patras, Patras, Greece
4 shared publications - Konstantinos Peppas
Department of Informatics and Communications, University of Peloponnese, 22100 Tripoli, Greece
4 shared publications - Nikolaos C. Sagias
Department of Informatics and Communications, University of Peloponnese, Tripoli, Greece
3 shared publications - George Malaperdas
Department of Environment, Ionian University, M. Minotou-Giannopoulou str. Panagoula, 29100 Zakynthos, Greece
1 shared publication - Nikolaos Simantiris
Department of Environment, Ionian University, 29100 Zakynthos, Greece
1 shared publication - Spyridon K. Chronopoulos
Electronics-Telecommunications and Applications Laboratory, Physics Department, University of Ioannina, 45110 Ioannina, Greece
1 shared publication
Latest Publications
- Open Access
- 17 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3663
Hardware Aspects of Machine Learning-Based Cardiac Fibrillation Diagnosis
This paper presents the hardware aspects of a Hjorth-parameter deep neural network (DNN)-based cardiac fibrillation diagnosis pipeline targeting low-power Internet of Medical Things (IoMT) devices and ASIC implementations. Building on earlier edge-to-cloud studies where Hjorth activity, mobility, and complexity were computed in software on microcontrollers and classified by a floating-point DNN, we introduce a fully synthesizable fixed-point hardware module that computes these parameters in real time, together with a quantized neural network (QNN) operating directly on the resulting fixed-point features. The Hjorth block includes derivative generation, accumulator banks, variance computation, and hardware divider and square-root units. Using the Shandong Provincial Hospital Database (SPHD) as in our previous work, we evaluate the impact of end-to-end fixed-point quantization on the AF-related arrhythmia detection performance for bit widths between 6 and 16 bits. For 10–12-bit configurations, the quantized pipeline achieves accuracy of approximately 93.7% and an area under the ROC curve (AUC) above 0.97, closely matching the floating-point baseline while significantly reducing the arithmetic complexity and memory footprint. ASIC synthesis in a 28 nm CMOS standard-cell library shows that the complete atrial detector core, integrating the Hjorth extractor and the hardware fully connected QNN, occupies on the order of and dissipates about 3 mW, with a critical-path delay of 7.08 ns. For the optimal 10–12-bit operating points, the synthesized core achieves per-inference energy in the range of 18.6–19.0 nJ (18,600–19,000 pJ) per classification, confirming its suitability for integration into wearable and IoMT ECG monitoring nodes. These results demonstrate that co-designed fixed-point Hjorth hardware and quantized DNNs can deliver a favorable trade-off between diagnostic performance, area, power, latency, and per-inference energy compared with existing MCU-, FPGA-, and ASIC-based ECG classifiers.- 17 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (16) , 3663
Open AccessHardware Aspects of Machine Learning-Based Cardiac Fibrillation Diagnosis
This paper presents the hardware aspects of a Hjorth-parameter deep neural network (DNN)-based cardiac fibrillation diagnosis pipeline targeting low-power Internet of Medical Things (IoMT) devices and ASIC implementations. Building on earlier edge-to-cloud studies where Hjorth activity, mobility, and complexity were computed in software on microcontrollers and classified by a floating-point DNN, we introduce a fully synthesizable fixed-point hardware module that computes these parameters in real time, together with a quantized neural network (QNN) operating directly on the resulting fixed-point features. The Hjorth block includes derivative generation, accumulator banks, variance computation, and hardware divider and square-root units. Using the Shandong Provincial Hospital Database (SPHD) as in our previous work, we evaluate the impact of end-to-end fixed-point quantization on the AF-related arrhythmia detection performance for bit widths between 6 and 16 bits. For 10–12-bit configurations, the quantized pipeline achieves accuracy of approximately 93.7% and an area under the ROC curve (AUC) above 0.97, closely matching the floating-point baseline while significantly reducing the arithmetic complexity and memory footprint. ASIC synthesis in a 28 nm CMOS standard-cell library shows that the complete atrial detector core, integrating the Hjorth extractor and the hardware fully connected QNN, occupies on the order of and dissipates about 3 mW, with a critical-path delay of 7.08 ns. For the optimal 10–12-bit operating points, the synthesized core achieves per-inference energy in the range of 18.6–19.0 nJ (18,600–19,000 pJ) per classification, confirming its suitability for integration into wearable and IoMT ECG monitoring nodes. These results demonstrate that co-designed fixed-point Hjorth hardware and quantized DNNs can deliver a favorable trade-off between diagnostic performance, area, power, latency, and per-inference energy compared with existing MCU-, FPGA-, and ASIC-based ECG classifiers. - Open Access
- 10 July 2026
- Published by MDPI AG in Preprints.org
Hardware Aspects of Machine Learning-Based Cardiac Fibrillation Diagnosis
This paper presents the hardware aspects of a Hjorth-parameter and deep neural network 2 (DNN)–based cardiac fibrillation diagnosis pipeline targeting low-power Internet of Medi- 3 cal Things (IoMT) devices and ASIC implementations. Building on earlier edge-to-cloud 4 studies where Hjorth activity, mobility, and complexity were computed in software on 5 microcontrollers and classified by a floating-point DNN, we introduce a fully synthesizable 6 fixed-point hardware module that computes these parameters in real time, together with a 7 quantized neural network (QNN) operating directly on the resulting fixed-point features. 8 The Hjorth block includes derivative generation, accumulator banks, variance computa- 9 tion, and hardware divider and square-root units. Using the Shandong Provincial Hospital 10 Database (SPHD) and the same 1-minute ECG windowing protocol as in our previous work, 11 we evaluate the impact of end-to-end fixed-point quantization on AF-related arrhythmia 12 detection performance for bit-widths between 6 and 16 bits. For 10–12-bit configurations, 13 the quantized pipeline achieves accuracy of approximately 93.7% and area under the ROC 14 curve (AUC) above 0.97, closely matching the floating-point baseline while significantly 15 reducing arithmetic complexity and memory footprint. ASIC synthesis in a 28 nm CMOS 16 standard-cell library shows that the complete atrial_detector core, integrating the Hjorth 17 extractor and the hardware fully connected QNN, occupies on the order of 2 × 104 µm2 and 18 dissipates about 3 mW, with a critical-path delay of 7.08 ns, confirming its suitability for 19 integration into wearable and IoMT ECG monitoring nodes. These results demonstrate that 20 co-designed fixed-point Hjorth hardware and quantized DNNs can deliver a favourable 21 trade-off between diagnostic performance, area, power, and latency compared with existing 22 MCU-, FPGA-, and ASIC-based ECG classifiers.
- 10 July 2026
- Published by MDPI AG in Preprints.org
Open AccessHardware Aspects of Machine Learning-Based Cardiac Fibrillation Diagnosis
This paper presents the hardware aspects of a Hjorth-parameter and deep neural network 2 (DNN)–based cardiac fibrillation diagnosis pipeline targeting low-power Internet of Medi- 3 cal Things (IoMT) devices and ASIC implementations. Building on earlier edge-to-cloud 4 studies where Hjorth activity, mobility, and complexity were computed in software on 5 microcontrollers and classified by a floating-point DNN, we introduce a fully synthesizable 6 fixed-point hardware module that computes these parameters in real time, together with a 7 quantized neural network (QNN) operating directly on the resulting fixed-point features. 8 The Hjorth block includes derivative generation, accumulator banks, variance computa- 9 tion, and hardware divider and square-root units. Using the Shandong Provincial Hospital 10 Database (SPHD) and the same 1-minute ECG windowing protocol as in our previous work, 11 we evaluate the impact of end-to-end fixed-point quantization on AF-related arrhythmia 12 detection performance for bit-widths between 6 and 16 bits. For 10–12-bit configurations, 13 the quantized pipeline achieves accuracy of approximately 93.7% and area under the ROC 14 curve (AUC) above 0.97, closely matching the floating-point baseline while significantly 15 reducing arithmetic complexity and memory footprint. ASIC synthesis in a 28 nm CMOS 16 standard-cell library shows that the complete atrial_detector core, integrating the Hjorth 17 extractor and the hardware fully connected QNN, occupies on the order of 2 × 104 µm2 and 18 dissipates about 3 mW, with a critical-path delay of 7.08 ns, confirming its suitability for 19 integration into wearable and IoMT ECG monitoring nodes. These results demonstrate that 20 co-designed fixed-point Hjorth hardware and quantized DNNs can deliver a favourable 21 trade-off between diagnostic performance, area, power, and latency compared with existing 22 MCU-, FPGA-, and ASIC-based ECG classifiers.
- Open Access
- 13 May 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (10) , 4839
An IoT-Based Real-Time Monitoring and Alert System for Sea Turtle Nest Protection
This paper presents a low-cost Internet-of-Things (IoT) telemetry and alerting system for monitoring and protecting sea turtle nests. The proposed platform integrates temperature, humidity, vibration, ultrasonic proximity, and ambient light sensors into an autonomous sensing node based on the ESP8266 microcontroller. Measurements are transmitted wirelessly to a cloud backend for real-time visualization and rule-based alert generation. The system is designed to support continuous nest-level monitoring and rapid response to environmental and anthropogenic threats such as overheating, artificial light exposure during hatching, and physical disturbance. In contrast to approaches that require extensive historical datasets or machine-learning models, the proposed solution employs transparent threshold-based rules that provide reliable operation without training data. The platform emphasizes low cost, ease of deployment, and scalability, making it suitable for large-scale conservation deployments across multiple nesting sites. It provides conservation practitioners with actionable situational awareness that complements existing field-based monitoring and protection strategies.
- 13 May 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (10) , 4839
Open AccessAn IoT-Based Real-Time Monitoring and Alert System for Sea Turtle Nest Protection
This paper presents a low-cost Internet-of-Things (IoT) telemetry and alerting system for monitoring and protecting sea turtle nests. The proposed platform integrates temperature, humidity, vibration, ultrasonic proximity, and ambient light sensors into an autonomous sensing node based on the ESP8266 microcontroller. Measurements are transmitted wirelessly to a cloud backend for real-time visualization and rule-based alert generation. The system is designed to support continuous nest-level monitoring and rapid response to environmental and anthropogenic threats such as overheating, artificial light exposure during hatching, and physical disturbance. In contrast to approaches that require extensive historical datasets or machine-learning models, the proposed solution employs transparent threshold-based rules that provide reliable operation without training data. The platform emphasizes low cost, ease of deployment, and scalability, making it suitable for large-scale conservation deployments across multiple nesting sites. It provides conservation practitioners with actionable situational awareness that complements existing field-based monitoring and protection strategies.
- Open Access
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 196374-196387
A Machine Learning-Based Heart Disease Detection Scheme for Predicting Spontaneous Termination of Atrial Fibrillation
This study introduces an electrocardiogram (ECG) detection system for predicting the spontaneous termination of atrial fibrillation (AF). The proposed system uses a two-stage approach: first, it extracts features from the ECG signals using Hjorth parameters (activity, mobility, and complexity), and second, it applies a deep neural network (DNN) classifier to analyze these features. The system was validated using clinical data obtained from the Shandong Provincial Hospital Database (SPHD), which includes recordings of various types of AF episodes, such as non-terminating, immediately-terminating, and soon-terminating AF. Experimental results indicate that the proposed system achieves an accuracy of approximately 94%, with precision and F-measure scores of 0.95, demonstrating robust performance in identifying AF termination events. To further assess the model’s effectiveness, we performed confusion matrix and receiver operating characteristic (ROC) analysis. These results confirm the potential of the proposed system for real-time deployment in portable consumer electronic (CE) devices, maintaining low implementation complexity while offering reliable AF detection.
- 11 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 196374-196387
Open AccessA Machine Learning-Based Heart Disease Detection Scheme for Predicting Spontaneous Termination of Atrial Fibrillation
This study introduces an electrocardiogram (ECG) detection system for predicting the spontaneous termination of atrial fibrillation (AF). The proposed system uses a two-stage approach: first, it extracts features from the ECG signals using Hjorth parameters (activity, mobility, and complexity), and second, it applies a deep neural network (DNN) classifier to analyze these features. The system was validated using clinical data obtained from the Shandong Provincial Hospital Database (SPHD), which includes recordings of various types of AF episodes, such as non-terminating, immediately-terminating, and soon-terminating AF. Experimental results indicate that the proposed system achieves an accuracy of approximately 94%, with precision and F-measure scores of 0.95, demonstrating robust performance in identifying AF termination events. To further assess the model’s effectiveness, we performed confusion matrix and receiver operating characteristic (ROC) analysis. These results confirm the potential of the proposed system for real-time deployment in portable consumer electronic (CE) devices, maintaining low implementation complexity while offering reliable AF detection.