RHRudolf Heer

Rudolf Heer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rudolf Heer has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Tiny Machine Learning Implementation for a Textile-Integrated Breath Rate Sensor

    by Kenneth Egwu, Rudolf Heer, Ferenc Ender, Georgios Kokkinis

    Respiratory rate (RR) is a critical indicator of physiological status, yet unobtrusive and continuous RR monitoring remains challenging, particularly in wearable applications that require soft, lightweight, and low-power sensing systems. This paper presents an integrated approach that combines a textile-embedded embroidered strain-gauge sensor with Tiny Machine Learning (TinyML) to enable real-time, on-device RR estimation. The sensing platform consists of a textile-integrated meander-pattern strain gauge and a fabric-mounted analog readout circuit, which together capture thoracic expansion during breathing. Two lightweight neural network models—a convolutional neural network (CNN) operating on raw respiratory waveforms and a dense neural network (DNN) operating on wavelet features—were developed and trained using a public strain-sensor dataset and a custom dataset collected with the textile system (TexHype dataset). Both models were optimized through 8-bit quantization and deployed to an STM32L4 microcontroller, where end-to-end on-device preprocessing, filtering, segmentation, normalization, and inference were performed. The CNN achieved the highest accuracy, with a mean absolute error (MAE) of 1.23 breaths per minute (BPM) on the TexHype dataset, but exhibited substantial inference latency (5.8–6.2 s) due to its computational complexity. In contrast, the wavelet-based DNN demonstrated lower accuracy (MAE 2.21 BPM) but achieved real-time performance with inference times of 18–96 ms, and a power overhead (ΔP=Pactive−Pidle) of approximately 3.3 mW during inference. Cross-dataset testing revealed limited generalization between different strain-sensor platforms. The findings highlight key trade-offs between accuracy, latency, and energy efficiency, and illustrate the potential of combining stretchable electronics with embedded intelligence to enable next-generation wearable respiratory monitoring systems.


  • Plasmonic-assisted Mach-Zehnder Interferometric photonic sensor using aluminum waveguides

    by E. Chatzianagnostou, A. Manolis, G. Dabos, D. Ketzaki, B. Chmielak, A.L. Giesecke, C. Porschatis, P. J. Cegielski, S. Suckow, L. Markey, et al.

    We demonstrate a CMOS compatible interferometric plasmo-photonic sensor exploiting SisN4 photonic and aluminum (Al) plasmonic stripe waveguides. Experimental evaluation revealed bulk sensitivity of 4764 nm/RIU, holding promise for ultra-sensitive and low cost sensing devices.


  • Multifrequency impedance measurement technique for wireless characterization of microbiological cell cultures

    by J. Wissenwasser, M. J. Vellekoop, W. Kapferer, G. Lepperdinger, R. Heer

    An impedance measurement system with probe signal frequencies up to 50 kHz with AC-probe voltages below 30 mV rms was integrated for wireless and battery-free monitoring of microbiological cell cultures. The here presented modular design and the use of state-of-the-art components greatly eases adoptions to a wide range of biotechnological applications without the need of bulky LCR-meters or potentiostats. The device had a power consumption of less than 2.5 mA at a 3.3 V single power supply and worked trouble-free within the humid environment of a cell culture incubator. Measurements on lumped RC-elements showed an error of less than 1% for absolute values and less than 1° regarding the phase of the complex impedance. The performance of sensor devices with interdigitated electrode structures for the measurement of adherent cell cultures was tested in the presence of phosphate-buffered saline solution in the humid atmosphere of an incubator for biological cell cultures.


  • Temperature Dependent Transport in Spin Valve Transistor Structures

    by R. Heer, J. Smoliner, J. Bornemeier, H. Brückl