Jaqueline dos Santos Soares
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jaqueline dos Santos Soares has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Aloisio M. Garcia
Departamento de Física, Universidade Federal de Minas Gerais, 31270-901 Belo Horizonte-MG, Brazil
1 shared publication- Ana Maria de Paula
Departamento de Física, Instituto de Ciências Exatas Universidade Federal de Minas Gerais Belo Horizonte Brazil
1 shared publication - André Luís Morais Ruela
Federal University of Ouro Preto, UFOP
1 shared publication - Eduardo Paulino Júnior
Departamento de Anatomia Patológica e Medicina Legal, Faculdade de Medicina, Universidade Federal de Minas Gerais, Avenida Prof. Alfredo Balena, 190, Belo Horizonte 30130-100, MG, Brazil
1 shared publication Felipe L. Magalhaes
Departamento de Anatomia e Imagem, Faculdade de Medicina, Universidade Federal de Minas Gerais, 30130-100 Belo Horizonte-MG, Brazil
1 shared publicationFlávIa de Souza Marques
Federal University of Ouro Preto, UFOP
1 shared publication
Latest Publications
- Open Access
- 17 July 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (33) , 49938-49953
Modulation of Donepezil Release Through Hydrophobic Ion- Pairing with Oleic Acid in Liquid Crystalline Nanodispersions for Transdermal Delivery
Precursor liquid crystals based on unsaturated monoglycerides, with or without oleic acid (OA), exhibited anisotropy characteristic of an inverse hexagonal phase. Donepezil-loaded liquid crystalline nanodispersions (LCNs) were produced by sonication and exhibited encapsulation efficiencies of 91.3–97.9%, with the OA-containing formulation (LCN-2) displaying a smaller particle size (183.0 ± 1.5 nm), lower polydispersity (0.183 ± 0.006), and improved colloidal stability over 90 days. NMR (1H NMR, 1D NOESY/ROESY and DOSY), molecular docking, and molecular dynamics simulations consistently demonstrated hydrophobic ion-pair formation between donepezil and oleic acid. These molecular interactions reduced drug mobility within the lipid domains, resulting in anomalous release behavior (n = 0.79), more sustained in vitro release, and an approximately 45% higher steady-state skin flux than the control donepezil solution. Overall, hydrophobic ion-pair formation with oleic acid represents an effective strategy to modulate drug release and enhance the transdermal performance of liquid crystalline nanodispersions for donepezil delivery.
- 17 July 2026
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 11 (33) , 49938-49953
Open AccessModulation of Donepezil Release Through Hydrophobic Ion- Pairing with Oleic Acid in Liquid Crystalline Nanodispersions for Transdermal Delivery
Precursor liquid crystals based on unsaturated monoglycerides, with or without oleic acid (OA), exhibited anisotropy characteristic of an inverse hexagonal phase. Donepezil-loaded liquid crystalline nanodispersions (LCNs) were produced by sonication and exhibited encapsulation efficiencies of 91.3–97.9%, with the OA-containing formulation (LCN-2) displaying a smaller particle size (183.0 ± 1.5 nm), lower polydispersity (0.183 ± 0.006), and improved colloidal stability over 90 days. NMR (1H NMR, 1D NOESY/ROESY and DOSY), molecular docking, and molecular dynamics simulations consistently demonstrated hydrophobic ion-pair formation between donepezil and oleic acid. These molecular interactions reduced drug mobility within the lipid domains, resulting in anomalous release behavior (n = 0.79), more sustained in vitro release, and an approximately 45% higher steady-state skin flux than the control donepezil solution. Overall, hydrophobic ion-pair formation with oleic acid represents an effective strategy to modulate drug release and enhance the transdermal performance of liquid crystalline nanodispersions for donepezil delivery.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 40, 1
Second harmonic generation microscopy as a cancer diagnosis tool
Summary form only given. Optical microscopy is one of the most important tool for understanding biology processes. Recently with the advance of femtosecond laser all the nonlinear optical processes have been included into optical microscopy methods and Second Harmonic Generation (SHG) microscopy has emerged as a powerful new optical imaging tool with applications in disease diagnostics [ 1-2]. The "gold standard" in cancer diagnostics is still the traditional histology analysis where accuracy depends on the experience and interpretation skill of the pathologist. A major development would be to use the SHG microscopy as a quantitative tool to cancer diagnosis. Here we show SHG imaging results of the collagen fibers in prostate cancer tissue that can be directly correlated with the cancer malignancy diagnostic [3]. We performed SHG imaging in a back-scattering geometry on the histological slides from the same biopsies that were analyzed by the pathologist. We studied prostate from patients treated at the the Urology Center of UFMG Hospital, Belo Horizonte. A 1 mm diameter punch biopsy was extracted from multiple peripheral zone of the prostate showing normal tissue and cancer tissue with Gleason scores ranging from 3 to 5. The study was approved by the UFMG Institutional Review Board and the Brazilian National Health Committee on the use of humans as experimental subjects. Written informed consent was obtained from all participants before their biopsy procedures. Figure 1 shows SHG images for normal and cancer tissue. The SHG images show major differences on the collagen fiber alignment that changes with cancer progression. The average direction of the fibers in the image was calculated and we obtained a value for the fiber anisotropy [4]. The statistical analysis is presented in the boxplot in figure 1. Note that both the average values (crosses) and the median lines (black center lines) are well separated for the normal and cancer tissue.In summary we present SHG measurements for prostate tissue that allows to obtain a quantitative analysis of the collagen fiber alignment. Our results suggest that this new method could be useful as a complementary tool on grading prostate cancer. Financial support: the Brazilian funding agencies Fapemig, CNPq, and Capes.
- 1 June 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 40, 1
Second harmonic generation microscopy as a cancer diagnosis tool
Summary form only given. Optical microscopy is one of the most important tool for understanding biology processes. Recently with the advance of femtosecond laser all the nonlinear optical processes have been included into optical microscopy methods and Second Harmonic Generation (SHG) microscopy has emerged as a powerful new optical imaging tool with applications in disease diagnostics [ 1-2]. The "gold standard" in cancer diagnostics is still the traditional histology analysis where accuracy depends on the experience and interpretation skill of the pathologist. A major development would be to use the SHG microscopy as a quantitative tool to cancer diagnosis. Here we show SHG imaging results of the collagen fibers in prostate cancer tissue that can be directly correlated with the cancer malignancy diagnostic [3]. We performed SHG imaging in a back-scattering geometry on the histological slides from the same biopsies that were analyzed by the pathologist. We studied prostate from patients treated at the the Urology Center of UFMG Hospital, Belo Horizonte. A 1 mm diameter punch biopsy was extracted from multiple peripheral zone of the prostate showing normal tissue and cancer tissue with Gleason scores ranging from 3 to 5. The study was approved by the UFMG Institutional Review Board and the Brazilian National Health Committee on the use of humans as experimental subjects. Written informed consent was obtained from all participants before their biopsy procedures. Figure 1 shows SHG images for normal and cancer tissue. The SHG images show major differences on the collagen fiber alignment that changes with cancer progression. The average direction of the fibers in the image was calculated and we obtained a value for the fiber anisotropy [4]. The statistical analysis is presented in the boxplot in figure 1. Note that both the average values (crosses) and the median lines (black center lines) are well separated for the normal and cancer tissue.In summary we present SHG measurements for prostate tissue that allows to obtain a quantitative analysis of the collagen fiber alignment. Our results suggest that this new method could be useful as a complementary tool on grading prostate cancer. Financial support: the Brazilian funding agencies Fapemig, CNPq, and Capes.