Maciej Kozarski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Maciej Kozarski has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Marek Darowski
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, ul. Ks. Trojdena 4, 02-109 Warsaw, Poland
7 shared publications - Krzysztof Zieliński
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
5 shared publications - Barbara Stankiewicz
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
4 shared publications - Krzysztof Jakub Pałko
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
4 shared publications - Tomasz Urbankowski
Department of Modeling and Supporting of Internal Organs Functions, Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
3 shared publications Gianfranco Ferrari
Nałęcz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
2 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-13
Model-Based Elastic–Resistive Partitioning of Inspiratory Mechanical Power During Conventional and Energy-Targeted Ventilation in a Hybrid Respiratory Simulator
Purpose: Mechanical power provides a global description of the energetic load imposed by mechanical ventilation, but similar total values may reflect different elastic and resistive components. This study applied a model-based framework to characterize elastic and resistive inspiratory mechanical power during conventional and investigational energy-targeted ventilation in a hybrid respiratory simulator. Methods: An experimental bench study was performed using a hybrid respiratory simulator coupled with a prototype ventilator. Four respiratory system conditions were simulated: normal mechanics and mild, moderate, and severe ARDS-like elastic impairment. Compliance was reduced from 60 to 30 mL/cmH 2 O, while resistance was kept constant at 10 cmH 2 O/L/s. Volume-controlled, pressure-controlled, and mechanical power-controlled ventilation were evaluated at respiratory rates of 10, 15, and 20 breaths/min. Maximal and mean elastic and resistive inspiratory mechanical power were assessed. Results: Ventilation mode significantly affected all analyzed power components. Mechanical power-controlled ventilation produced the lowest pooled maximal elastic power, with reductions of 16.2% versus volume-controlled ventilation and 24.3% versus pressure-controlled ventilation (both p < 0.001). This effect was most evident at lower respiratory rates and under more severe elastic impairment. For resistive power, pressure-controlled ventilation produced the highest values, volume-controlled ventilation the lowest, and mechanical power-controlled ventilation remained intermediate. Conclusion: Component-level analysis revealed ventilation mode-dependent differences in inspiratory energy transfer that were not captured by total mechanical power alone.
- 27 October 2026
- Published by Springer Nature in Annals of Biomedical Engineering
- p. 1-13
Open AccessModel-Based Elastic–Resistive Partitioning of Inspiratory Mechanical Power During Conventional and Energy-Targeted Ventilation in a Hybrid Respiratory Simulator
Purpose: Mechanical power provides a global description of the energetic load imposed by mechanical ventilation, but similar total values may reflect different elastic and resistive components. This study applied a model-based framework to characterize elastic and resistive inspiratory mechanical power during conventional and investigational energy-targeted ventilation in a hybrid respiratory simulator. Methods: An experimental bench study was performed using a hybrid respiratory simulator coupled with a prototype ventilator. Four respiratory system conditions were simulated: normal mechanics and mild, moderate, and severe ARDS-like elastic impairment. Compliance was reduced from 60 to 30 mL/cmH 2 O, while resistance was kept constant at 10 cmH 2 O/L/s. Volume-controlled, pressure-controlled, and mechanical power-controlled ventilation were evaluated at respiratory rates of 10, 15, and 20 breaths/min. Maximal and mean elastic and resistive inspiratory mechanical power were assessed. Results: Ventilation mode significantly affected all analyzed power components. Mechanical power-controlled ventilation produced the lowest pooled maximal elastic power, with reductions of 16.2% versus volume-controlled ventilation and 24.3% versus pressure-controlled ventilation (both p < 0.001). This effect was most evident at lower respiratory rates and under more severe elastic impairment. For resistive power, pressure-controlled ventilation produced the highest values, volume-controlled ventilation the lowest, and mechanical power-controlled ventilation remained intermediate. Conclusion: Component-level analysis revealed ventilation mode-dependent differences in inspiratory energy transfer that were not captured by total mechanical power alone.
- Open Access
- 1 June 2026
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 32 (2) , 79-88
Power-Based Optimization of Ventilation Frequency Without Compliance or Resistance Measurements: A Simulation Study
Background: Mechanical ventilation remains a life-saving intervention but carries risks such as barotrauma, volutrauma, ergotrauma, and hemodynamic disturbances. Modern ventilators incorporate adaptive strategies to minimize the work of breathing (WOB), often relying on measurements of respiratory resistance and compliance. However, such measurements are prone to error and often unavailable in real time. This study presents a novel adaptive ventilation concept that dynamically identifies the optimal ventilation frequency minimizing WOB per minute without requiring resistance or compliance measurements. Material and methods: Using a validated hybrid respiratory simulator, we conducted simulation experiments across three representative lung conditions: normal mechanics, decreased compliance, and increased resistance. The system conceptually searched for the ventilation frequency minimizing WOB/min while maintaining constant alveolar ventilation, with the optimization process emulated manually in this proof-of-concept study. Results: Results confirmed that WOB/min follows a parabolic function of frequency, with optimal frequencies found at 18, 21, and 12 breaths per minute for normal, restrictive, and obstructive patterns, respectively. Importantly, the optimal frequencies aligned with ranges observed in clinical studies of adaptive support ventilation. Furthermore, the system demonstrated natural variability in ventilation rate and tidal volume, which may contribute to alveolar recruitment. Conclusion: Our findings validate the concept of energy-based optimization of ventilation independent of online lung mechanics assessment. The proposed method is robust, physiologically grounded, and may become suitable for integration into next-generation intelligent ventilators after full automation of the adaptive algorithm. Future work will focus on full automation of the adaptive algorithm and its evaluation in preclinical and clinical studies targeting WOB and mechanical power minimization.
- 1 June 2026
- Published by Walter de Gruyter GmbH in Polish Journal of Medical Physics And Engineering
- Vol. 32 (2) , 79-88
Open AccessPower-Based Optimization of Ventilation Frequency Without Compliance or Resistance Measurements: A Simulation Study
Background: Mechanical ventilation remains a life-saving intervention but carries risks such as barotrauma, volutrauma, ergotrauma, and hemodynamic disturbances. Modern ventilators incorporate adaptive strategies to minimize the work of breathing (WOB), often relying on measurements of respiratory resistance and compliance. However, such measurements are prone to error and often unavailable in real time. This study presents a novel adaptive ventilation concept that dynamically identifies the optimal ventilation frequency minimizing WOB per minute without requiring resistance or compliance measurements. Material and methods: Using a validated hybrid respiratory simulator, we conducted simulation experiments across three representative lung conditions: normal mechanics, decreased compliance, and increased resistance. The system conceptually searched for the ventilation frequency minimizing WOB/min while maintaining constant alveolar ventilation, with the optimization process emulated manually in this proof-of-concept study. Results: Results confirmed that WOB/min follows a parabolic function of frequency, with optimal frequencies found at 18, 21, and 12 breaths per minute for normal, restrictive, and obstructive patterns, respectively. Importantly, the optimal frequencies aligned with ranges observed in clinical studies of adaptive support ventilation. Furthermore, the system demonstrated natural variability in ventilation rate and tidal volume, which may contribute to alveolar recruitment. Conclusion: Our findings validate the concept of energy-based optimization of ventilation independent of online lung mechanics assessment. The proposed method is robust, physiologically grounded, and may become suitable for integration into next-generation intelligent ventilators after full automation of the adaptive algorithm. Future work will focus on full automation of the adaptive algorithm and its evaluation in preclinical and clinical studies targeting WOB and mechanical power minimization.
- Open Access
Virtual and Artificial Cardiorespiratory Patients in Medicine and Biomedical Engineering
Recently, ‘medicine in silico’ has been strongly encouraged due to ethical and legal limitations related to animal experiments and investigations conducted on patients. Computer models, particularly the very complex ones (virtual patients—VP), can be used in medical education and biomedical research as well as in clinical applications. Simpler patient-specific models may aid medical procedures. However, computer models are unfit for medical devices testing. Hybrid (i.e., numerical–physical) models do not have this disadvantage. In this review, the chosen approach to the cardiovascular system and/or respiratory system modeling was discussed with particular emphasis given to the hybrid cardiopulmonary simulator (the artificial patient), that was elaborated by the authors. The VP is useful in the education of forced spirometry, investigations of cardiopulmonary interactions (including gas exchange) and its influence on pulmonary resistance during artificial ventilation, and explanation of phenomena observed during thoracentesis. The artificial patient is useful, inter alia, in staff training and education, investigations of cardiorespiratory support and the testing of several medical devices, such as ventricular assist devices and a membrane-based artificial heart.
Open AccessVirtual and Artificial Cardiorespiratory Patients in Medicine and Biomedical Engineering
Recently, ‘medicine in silico’ has been strongly encouraged due to ethical and legal limitations related to animal experiments and investigations conducted on patients. Computer models, particularly the very complex ones (virtual patients—VP), can be used in medical education and biomedical research as well as in clinical applications. Simpler patient-specific models may aid medical procedures. However, computer models are unfit for medical devices testing. Hybrid (i.e., numerical–physical) models do not have this disadvantage. In this review, the chosen approach to the cardiovascular system and/or respiratory system modeling was discussed with particular emphasis given to the hybrid cardiopulmonary simulator (the artificial patient), that was elaborated by the authors. The VP is useful in the education of forced spirometry, investigations of cardiopulmonary interactions (including gas exchange) and its influence on pulmonary resistance during artificial ventilation, and explanation of phenomena observed during thoracentesis. The artificial patient is useful, inter alia, in staff training and education, investigations of cardiorespiratory support and the testing of several medical devices, such as ventricular assist devices and a membrane-based artificial heart.
- 1 October 2021
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 41 (4) , 1365-1377
Assessment of the VAD – Native ventricle pumping system by an equivalent pump: A computational model based procedure
- 1 October 2021
- Published by Elsevier in Biocybernetics and Biomedical Engineering
- Vol. 41 (4) , 1365-1377
Assessment of the VAD – Native ventricle pumping system by an equivalent pump: A computational model based procedure
- 23 August 2019
- Published by Springer Nature
- p. 35-44
A New Method and Device for Differentiating Elastic and Resistive Properties of the Respiratory System
- 23 August 2019
- Published by Springer Nature
- p. 35-44
A New Method and Device for Differentiating Elastic and Resistive Properties of the Respiratory System
- Open Access
- 2 November 2012
- Published by Wiley in Artificial Organs
- Vol. 37 (3) , 237-247
Effects of Intra‐Aortic Balloon Pump Timing on Baroreflex Activities in a Closed‐Loop Cardiovascular Hybrid Model
Despite 50 years of research to assess the intra‐aortic balloon pump (IABP) effects on patients' hemodynamics, some issues related to the effects of this therapy are still not fully understood. One of these issues is the effect of IABP, its inflation timing and duration on peripheral circulation autonomic controls. This work provides a systematic analysis of IABP effects on baroreflex using a cardiovascular hybrid model, which consists of computational and hydraulic submodels. The work also included a baroreflex computational model that was connected to a hydraulic model with a 40‐cm3 balloon. The IABP was operated at different inflation trigger timings (−0.14 to 0.31 s) and inflation durations (0.05–0.45 s), with time of the dicrotic notch being taken as t = 0. Baroreflex‐dependent parameters—afferent and efferent pathway activity, heart rate, peripheral resistance, and venous tone—were evaluated at each of the inflation trigger times and durations considered. Balloon early inflation (0.09 s before the dicrotic notch) with inflation duration of 0.25 s generated a maximum net increment of afferent pathway activity of 10%, thus leading to a decrement of efferent sympathetic activity by 15.3% compared with baseline values. These times also resulted in a reduction in peripheral resistance and heart rate by 4 and 4.3% compared with baseline value. We conclude that optimum IABP triggering time results in positive effects on peripheral circulation autonomic controls. Conversely, if the balloon is not properly timed, peripheral resistance and heart rate may even increase, which could lead to detrimental outcomes.
- 2 November 2012
- Published by Wiley in Artificial Organs
- Vol. 37 (3) , 237-247
Open AccessEffects of Intra‐Aortic Balloon Pump Timing on Baroreflex Activities in a Closed‐Loop Cardiovascular Hybrid Model
Despite 50 years of research to assess the intra‐aortic balloon pump (IABP) effects on patients' hemodynamics, some issues related to the effects of this therapy are still not fully understood. One of these issues is the effect of IABP, its inflation timing and duration on peripheral circulation autonomic controls. This work provides a systematic analysis of IABP effects on baroreflex using a cardiovascular hybrid model, which consists of computational and hydraulic submodels. The work also included a baroreflex computational model that was connected to a hydraulic model with a 40‐cm3 balloon. The IABP was operated at different inflation trigger timings (−0.14 to 0.31 s) and inflation durations (0.05–0.45 s), with time of the dicrotic notch being taken as t = 0. Baroreflex‐dependent parameters—afferent and efferent pathway activity, heart rate, peripheral resistance, and venous tone—were evaluated at each of the inflation trigger times and durations considered. Balloon early inflation (0.09 s before the dicrotic notch) with inflation duration of 0.25 s generated a maximum net increment of afferent pathway activity of 10%, thus leading to a decrement of efferent sympathetic activity by 15.3% compared with baseline values. These times also resulted in a reduction in peripheral resistance and heart rate by 4 and 4.3% compared with baseline value. We conclude that optimum IABP triggering time results in positive effects on peripheral circulation autonomic controls. Conversely, if the balloon is not properly timed, peripheral resistance and heart rate may even increase, which could lead to detrimental outcomes.
- 1 December 2003
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 26 (12) , 1104-1114
Modelling of Cardiovascular System: Development of a Hybrid (Numerical-Physical) Model
Physical models of the circulation are used for research, training and for testing of implantable active and passive circulatory prosthetic and assistance devices. However, in comparison with numerical models, they are rigid and expensive. To overcome these limitations, we have developed a model of the circulation based on the merging of a lumped parameter physical model into a numerical one (producing therefore a hybrid). The physical model is limited to the barest essentials and, in this application, developed to test the principle, it is a windkessel representing the systemic arterial tree. The lumped parameters numerical model was developed in LabVIEW ™ environment and represents pulmonary and systemic circulation (except the systemic arterial tree). Based on the equivalence between hydraulic and electrical circuits, this prototype was developed connecting the numerical model to an electrical circuit - the physical model. This specific solution is valid mainly educationally but permits the development of software and the verification of preliminary results without using cumbersome hydraulic circuits. The interfaces between numerical and electrical circuits are set up by a voltage controlled current generator and a voltage controlled voltage generator. The behavior of the model is analyzed based on the ventricular pressure-volume loops and on the time course of arterial and ventricular pressures and flow in different circulatory conditions. The model can represent hemodynamic relationships in different ventricular and circulatory conditions.
- 1 December 2003
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 26 (12) , 1104-1114
Modelling of Cardiovascular System: Development of a Hybrid (Numerical-Physical) Model
Physical models of the circulation are used for research, training and for testing of implantable active and passive circulatory prosthetic and assistance devices. However, in comparison with numerical models, they are rigid and expensive. To overcome these limitations, we have developed a model of the circulation based on the merging of a lumped parameter physical model into a numerical one (producing therefore a hybrid). The physical model is limited to the barest essentials and, in this application, developed to test the principle, it is a windkessel representing the systemic arterial tree. The lumped parameters numerical model was developed in LabVIEW ™ environment and represents pulmonary and systemic circulation (except the systemic arterial tree). Based on the equivalence between hydraulic and electrical circuits, this prototype was developed connecting the numerical model to an electrical circuit - the physical model. This specific solution is valid mainly educationally but permits the development of software and the verification of preliminary results without using cumbersome hydraulic circuits. The interfaces between numerical and electrical circuits are set up by a voltage controlled current generator and a voltage controlled voltage generator. The behavior of the model is analyzed based on the ventricular pressure-volume loops and on the time course of arterial and ventricular pressures and flow in different circulatory conditions. The model can represent hemodynamic relationships in different ventricular and circulatory conditions.