Selda Gökçe Erdal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Selda Gökçe Erdal has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Aynur Beyza Çavuşculu Güdül
Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Kozlu, Turkey
1 shared publication- Ayşegül KÖROĞLU
Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, 67600 Zonguldak, Türkiye
1 shared publication Ayşegül Köroğlu
Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Kozlu, Turkey
1 shared publication- Ayşegül Köroğlu
Department of Prosthodontics, Faculty of Dentistry, Zonguldak Bülent Ecevit University, Zonguldak 67600, Turkey
1 shared publication - Baki Hazer
Department of Aircraft Airframe Engine Maintenance Kapadokya University Nevsehir Turkey
1 shared publication - Doğu Ömür Dede
Department of Prosthodontics, Faculty of Dentistry, Ordu University, 52200 Ordu, Türkiye
1 shared publication
Latest Publications
- Open Access
Effect of Sulfonate-, Phosphonate-, and Lipoate-Functional Modifiers on the Mechanical and Thermal Properties of Polymethyl Methacrylate Denture Base Resin
Objective: This study aimed to evaluate the mechanical and thermal properties of heat-polymerized polymethyl methacrylate (PMMA) denture base resin modified with different concentrations of sodium 4-styrenesulfonate (SO), 5,5-bis(diisopropoxyphosphoryl)pentyl methacrylate (PO), and 5,5-bis(diisopropoxyphosphoryl)pentyl lipoate (LIP). Materials and Methods: Heat-polymerized PMMA specimens were divided into a control group and experimental groups modified with 2%, 3%, or 5% SO, PO, or LIP (n = 8 per group). Maximum deflection, flexural strength, and Young’s modulus were determined using a three-point bending test. Surface hardness was evaluated using the Vickers hardness test, thermal behavior was assessed by thermogravimetric analysis (TGA), and fracture surfaces were examined by scanning electron microscopy (SEM). Data were analyzed using two-way ANOVA (modifier type × concentration) with Bonferroni-adjusted pairwise comparisons, and comparisons including the control group were performed using Welch’s or one-way ANOVA followed by Tamhane’s T2 or Bonferroni post hoc tests, depending on the homogeneity of variances (α = 0.05). Results: Modifier type significantly affected maximum deflection, flexural strength, Young’s modulus, and Vickers hardness of specimens. The LIP-containing groups showed the highest mean deflection values but significantly lower flexural strength, Young’s modulus, and hardness than the control group. In contrast, the SO-containing groups generally maintained mechanical properties closer to those of unmodified PMMA. TGA showed that all modifiers altered the thermal degradation profile of PMMA, with PO increasing the main degradation temperature by approximately 40 °C. Conclusions: The investigated modifiers produced distinct, modifier-dependent changes in the mechanical and thermal behavior of heat-polymerized PMMA. Although LIP increased deformation capacity, this occurred at the expense of flexural strength and stiffness. SO and PO modifications showed comparatively smaller changes in mechanical properties at selected concentrations. Further studies including direct fracture-toughness, fatigue, and clinically relevant aging assessments are required to determine whether these modifications provide functional advantages for denture base applications.
Open AccessEffect of Sulfonate-, Phosphonate-, and Lipoate-Functional Modifiers on the Mechanical and Thermal Properties of Polymethyl Methacrylate Denture Base Resin
Objective: This study aimed to evaluate the mechanical and thermal properties of heat-polymerized polymethyl methacrylate (PMMA) denture base resin modified with different concentrations of sodium 4-styrenesulfonate (SO), 5,5-bis(diisopropoxyphosphoryl)pentyl methacrylate (PO), and 5,5-bis(diisopropoxyphosphoryl)pentyl lipoate (LIP). Materials and Methods: Heat-polymerized PMMA specimens were divided into a control group and experimental groups modified with 2%, 3%, or 5% SO, PO, or LIP (n = 8 per group). Maximum deflection, flexural strength, and Young’s modulus were determined using a three-point bending test. Surface hardness was evaluated using the Vickers hardness test, thermal behavior was assessed by thermogravimetric analysis (TGA), and fracture surfaces were examined by scanning electron microscopy (SEM). Data were analyzed using two-way ANOVA (modifier type × concentration) with Bonferroni-adjusted pairwise comparisons, and comparisons including the control group were performed using Welch’s or one-way ANOVA followed by Tamhane’s T2 or Bonferroni post hoc tests, depending on the homogeneity of variances (α = 0.05). Results: Modifier type significantly affected maximum deflection, flexural strength, Young’s modulus, and Vickers hardness of specimens. The LIP-containing groups showed the highest mean deflection values but significantly lower flexural strength, Young’s modulus, and hardness than the control group. In contrast, the SO-containing groups generally maintained mechanical properties closer to those of unmodified PMMA. TGA showed that all modifiers altered the thermal degradation profile of PMMA, with PO increasing the main degradation temperature by approximately 40 °C. Conclusions: The investigated modifiers produced distinct, modifier-dependent changes in the mechanical and thermal behavior of heat-polymerized PMMA. Although LIP increased deformation capacity, this occurred at the expense of flexural strength and stiffness. SO and PO modifications showed comparatively smaller changes in mechanical properties at selected concentrations. Further studies including direct fracture-toughness, fatigue, and clinically relevant aging assessments are required to determine whether these modifications provide functional advantages for denture base applications.
- Top Cited PapersOpen Access
- 13 February 2026
- Published by Springer Nature in BMC Medical Education
- Vol. 26 (1)
The effectiveness of large language models in dental specialty questions: a comparative study in the field of prosthodontics
This study was aimed to compare the accuracy of four state-of-the-art large language models (LLMs)(ChatGPT-5, ChatGPT-4o, DeepSeek, and Gemini 2.5 Pro) on
- 13 February 2026
- Published by Springer Nature in BMC Medical Education
- Vol. 26 (1)
Top Cited PapersOpen AccessThe effectiveness of large language models in dental specialty questions: a comparative study in the field of prosthodontics
This study was aimed to compare the accuracy of four state-of-the-art large language models (LLMs)(ChatGPT-5, ChatGPT-4o, DeepSeek, and Gemini 2.5 Pro) on
- Open Access
Effect of Different Surface Treatments and Toothbrushing Durations on Surface Roughness and Color Stability of CAD/CAM Interim Crown Material
The clinical performance of interim restorations, particularly in the anterior region, largely depends on surface roughness (Ra) and color stability. This study investigated the influence of different toothbrushing durations on the surface roughness and color stability of CAD/CAM interim restorative materials subjected to varying polishing protocols. A total of 140 rectangular specimens (15 × 9 × 2 mm) were fabricated from highly cross-linked PMMA blocks (Telio-CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and allocated to two surface treatment groups: conventional polishing and surface coating with Optiglaze Color (GC Corp, Tokyo, Japan). Each group was further divided into seven subgroups (n = 10), including a control (no brushing) and groups that performed simulated brushing (DentArge TB-6.1, Analitik Medikal, Gaziantep, Turkiye) with distilled water or toothpaste (Colgate Total; Colgate-Palmolive, New York, NY, USA), for 2 weeks, 3 months, or 1 year. Ra values were recorded before (Ra0) and after brushing (Ra1), and color changes (ΔE00) following immersion in coffee solution were calculated. Statistical analysis was performed using a three-way ANOVA and Tukey’s HSD test (α = 0.05). Specimens coated with Optiglaze Color exhibited significantly lower Ra values compared with conventionally polished specimens (p < 0.05). The Con_Tp_1Yr group demonstrated the highest Ra value (0.53 ± 0.08 µm) compared to all other specimen groups (p < 0.05). A one-year brushing duration markedly increased ΔE00 values in both surface treatment groups regardless of brushing medium (p < 0.05). While surface coating was more effective than conventional polishing in obtaining smoother surfaces at all brushing durations, prolonged brushing with toothpaste produced a progressive increase in surface roughness in both treatments. Ra values increased consistently over time, with the most pronounced changes observed after one year of brushing. Within the limitations of using a single CAD/CAM material, it may be concluded that surface coating improves the initial smoothness of interim crowns; however, extended brushing and different brushing media can intensify color changes, indicating that the long-term stability of surface-coated interim restorations may be compromised under abrasive conditions.
Open AccessEffect of Different Surface Treatments and Toothbrushing Durations on Surface Roughness and Color Stability of CAD/CAM Interim Crown Material
The clinical performance of interim restorations, particularly in the anterior region, largely depends on surface roughness (Ra) and color stability. This study investigated the influence of different toothbrushing durations on the surface roughness and color stability of CAD/CAM interim restorative materials subjected to varying polishing protocols. A total of 140 rectangular specimens (15 × 9 × 2 mm) were fabricated from highly cross-linked PMMA blocks (Telio-CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and allocated to two surface treatment groups: conventional polishing and surface coating with Optiglaze Color (GC Corp, Tokyo, Japan). Each group was further divided into seven subgroups (n = 10), including a control (no brushing) and groups that performed simulated brushing (DentArge TB-6.1, Analitik Medikal, Gaziantep, Turkiye) with distilled water or toothpaste (Colgate Total; Colgate-Palmolive, New York, NY, USA), for 2 weeks, 3 months, or 1 year. Ra values were recorded before (Ra0) and after brushing (Ra1), and color changes (ΔE00) following immersion in coffee solution were calculated. Statistical analysis was performed using a three-way ANOVA and Tukey’s HSD test (α = 0.05). Specimens coated with Optiglaze Color exhibited significantly lower Ra values compared with conventionally polished specimens (p < 0.05). The Con_Tp_1Yr group demonstrated the highest Ra value (0.53 ± 0.08 µm) compared to all other specimen groups (p < 0.05). A one-year brushing duration markedly increased ΔE00 values in both surface treatment groups regardless of brushing medium (p < 0.05). While surface coating was more effective than conventional polishing in obtaining smoother surfaces at all brushing durations, prolonged brushing with toothpaste produced a progressive increase in surface roughness in both treatments. Ra values increased consistently over time, with the most pronounced changes observed after one year of brushing. Within the limitations of using a single CAD/CAM material, it may be concluded that surface coating improves the initial smoothness of interim crowns; however, extended brushing and different brushing media can intensify color changes, indicating that the long-term stability of surface-coated interim restorations may be compromised under abrasive conditions.