JXJingyue Xu

Jingyue Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jingyue Xu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Sensitive and mutiplexed microRNA quantification using amplified time-gated Förster resonance energy transfer

    by Jingyue Xu

    Quantification sensible et mutiplexée des microARNs en utilisant le transfert d'énergie par résonance de type Förster amplifié et résolu en temps: En tant que biomarqueurs de nouvelle génération, les microARNs sont associés à de nombreux cancers et maladies, ce qui a conduit à une forte demande pour le développement de méthodes cliniques de diagnostic des microARNs. Les technologies d'amplification isotherme, telles que l'amplification en cercle roulant et l'assemblage catalytique en épingle à cheveux, sont devenues des méthodes puissantes pour les dosages très rapides, spécifiques et sensibles des microARNs. Cette thèse se concentre sur le développement de biocapteurs de microARNs basés sur les technologies d'amplification isotherme et le transfert d'énergie par résonance de type Förster résolu en temps des complexes de lanthanide aux colorants organiques ou aux points quantiques. Les biocapteurs de microARNs amplifiés proposés ont des limites de détection très basses et sont utilisables dans des échantillons cliniques humains, révélant avec succès leurs pertinence pour le diagnostic du cancer. Comme la détection simultanée de plusieurs microARNs est très demandée, la détection temporelle multiplexée de microARNs est également effectuée basée sur les de durées de vie à l'état excité distinctes des complexes Tb et des colorants. De plus, le nanocapteur microARN amplifié basé sur des points Tb à quantique FRET, a démontré la possibilité d'une détection spectrale multiplexée de microARNs avec une sensibilité et une sélectivité élevées.

  • Aptamers-Based Sensing Strategy for 17β-Estradiol Through Fluorescence Resonance Energy Transfer Between Oppositely Charged CdTe Quantum Dots and Gold Nanoparticles

    by Ying Li, Ruifang Su, Jingyue Xu, Jiaxin Bie, Rui Sun, Luokai Wang, Xin Liu, Chunyan Sun

    A novel aptamers-based fluorescence resonance energy transfer (FRET) assay was developed employing the oppositely charged thioglycolic acid-capped CdTe quantum dots (TGA-CdTe QDs) and cysteamine-stabilized gold nanoparticles (cysteamine-AuNPs). The fluorescence of TGA-CdTe QDs was significantly quenched with addition of cysteamine-AuNPs via the FRET. The FRET process can be modulated by 17β-estradiol in that the specific recognition between 17β-estradiol and aptamers could show different effects on the aptamers-mediated aggregation of cysteamine-AuNPs, and correspondingly adjust the FRET process. The feasibility of the method has been demonstrated by carrying out the detection of 17β-estradiol with the wide linear range from 0.5·ng mL−1 to 150 ng·mL−1 and the low detection limit of 0.057 ng·mL−1. The established assay exhibited favorable selectivity towards 17β-estradiol over other endocrine disrupting compounds and probably coexisting chemicals in real samples. Furthermore, the assay has been successfully applied to detect 17β-estradiol in real tap water samples and feeds samples with good performance. The results were in full consistence with those from HPLC method, indicating the reliability of the detection system. The aptamers-based FRET assay is expected to offer a new opportunity for the rapid analysis of 17β-estradiol in real samples.


  • Visual Screening and Colorimetric Determination of Clenbuterol and Ractopamine Using Unmodified Gold Nanoparticles as Probe

    by Yeli Luo, Xin Liu, Hanting Gao, Ying Li, Jingyue Xu, Fei Shen, Chunyan Sun

    In this paper, a sensitive method for the colorimetric detection of clenbuterol and ractopamine using citrate-stabilized gold nanoparticles (AuNPs) as probe was developed. The concentration of clenbuterol and ractopamine could be determined with naked eyes or a UV-vis spectrometer. By optimizing the influence of NaHSO₄ and incubation time, clenbuterol could be detected in the linear range of 0.1-4 µg/mL with the detection limit of 0.0158 µg/mL, and ractopamine could be detected in the linear range of 1-9 µg/mL with the detection limit of 0.0229 µg/mL. The proposed method could be successfully applied to detect clenbuterol and ractopamine in pig urines by a simple pre-treatment with excellent recoveries. The proposed colorimetric assay exhibits good reproducibility and accuracy, providing a simple and rapid method for the analysis of clenbuterol and ractopamine.


  • Aptamer-based fluorescent detection of bisphenol A using nonconjugated gold nanoparticles and CdTe quantum dots

    by Ying Li, Jingyue Xu, Luokai Wang, Yanjun Huang, Jiajia Guo, Xianyi Cao, Fei Shen, Yeli Luo, Chunyan Sun