Dan Van Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dan Van Nguyen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Bibek Raut
Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47906, USA
3 shared publications - Jonathan Alexander Pasternak
Department of Animal and Food Sciences, University of Kentucky, Lexington, USA
3 shared publications - Mohit S. Verma
Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47906, USA
3 shared publications - Palla Gopal
Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN 47906, USA
3 shared publications - Virendra Kumar
Department of Agricultural and Biological Engineering, Purdue University, West Lafayette, IN 47906, USA
3 shared publications Aaron Ault
Department of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47906, USA
2 shared publications
Latest Publications
- Open Access
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (18) , 4970-4983
A solid-state heater-imager for quantitative evaluation of colorimetric isothermal nucleic acid amplification on paper
ThermiQuant™ VitroMini combines dual-sided thin-film heating with a transparent imaging window to minimize through-thickness temperature gradients and enable real-time quantitative analysis of isothermal nucleic acid amplification reactions.
- 16 September 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (18) , 4970-4983
Open AccessA solid-state heater-imager for quantitative evaluation of colorimetric isothermal nucleic acid amplification on paper
ThermiQuant™ VitroMini combines dual-sided thin-film heating with a transparent imaging window to minimize through-thickness temperature gradients and enable real-time quantitative analysis of isothermal nucleic acid amplification reactions.
- Open Access
A rapid, field-deployable paper-based biosensor for the detection of African swine fever virus in whole blood
African swine fever virus (ASFV) poses a major transboundary threat to global swine production, underscoring the need for rapid and field-deployable diagnostic tools. Although quantitative polymerase chain reaction (qPCR)-based assays are the standard molecular assay for ASFV detection, their reliance on centralized laboratory infrastructure, multi-step sample preparation, and trained personnel limit their utility for timely decision-making at the point of need (PON). Here, we report a portable molecular diagnostic platform that enables colorimetric quantitative loop-mediated isothermal amplification (qLAMP) directly from diluted whole blood on microfluidic paper-based analytical devices (μPADs). The assay targets the conserved ASFV viral protein 72 (VP72) and topoisomerase II (TOPII) genes and incorporates objective image-based colorimetric signal analysis to reduce user-dependent interpretation. Using plasmid DNA spiked into whole blood diluted to 5% (v/v) in 5% D-mannitol, the μPAD-LAMP assay achieved a limit of detection (LOD) of 25 copies per reaction (67 copies/μL of whole blood sample) for VP72 targets with no observed cross-reactivity against nine common swine pathogens, demonstrating 100% analytical sensitivity and specificity during in-house testing and 90% and 92% analytical sensitivity and specificity respectively in an external laboratory evaluation. The complete assay was performed within 60 minutes using a portable heating and imaging platform. Together, these results demonstrate a simple, DNA extraction-free molecular diagnostic approach that enables rapid and reliable ASFV detection from whole blood applicable to field-relevant conditions.
Open AccessA rapid, field-deployable paper-based biosensor for the detection of African swine fever virus in whole blood
African swine fever virus (ASFV) poses a major transboundary threat to global swine production, underscoring the need for rapid and field-deployable diagnostic tools. Although quantitative polymerase chain reaction (qPCR)-based assays are the standard molecular assay for ASFV detection, their reliance on centralized laboratory infrastructure, multi-step sample preparation, and trained personnel limit their utility for timely decision-making at the point of need (PON). Here, we report a portable molecular diagnostic platform that enables colorimetric quantitative loop-mediated isothermal amplification (qLAMP) directly from diluted whole blood on microfluidic paper-based analytical devices (μPADs). The assay targets the conserved ASFV viral protein 72 (VP72) and topoisomerase II (TOPII) genes and incorporates objective image-based colorimetric signal analysis to reduce user-dependent interpretation. Using plasmid DNA spiked into whole blood diluted to 5% (v/v) in 5% D-mannitol, the μPAD-LAMP assay achieved a limit of detection (LOD) of 25 copies per reaction (67 copies/μL of whole blood sample) for VP72 targets with no observed cross-reactivity against nine common swine pathogens, demonstrating 100% analytical sensitivity and specificity during in-house testing and 90% and 92% analytical sensitivity and specificity respectively in an external laboratory evaluation. The complete assay was performed within 60 minutes using a portable heating and imaging platform. Together, these results demonstrate a simple, DNA extraction-free molecular diagnostic approach that enables rapid and reliable ASFV detection from whole blood applicable to field-relevant conditions.
- Open Access
A solid-state heater-imager for quantitative evaluation of colorimetric isothermal nucleic acid amplification on paper
Maintaining precise isothermal conditions in portable nucleic acid amplification tests (NAATs) is critical for reproducible results but remains challenging with conventional single-sided thin-film heaters, which exhibit temperature gradients and strong dependence on ambient conditions. To close this gap, we engineered ThermiQuant™ VitroMini, a dual-sided heater design that achieves volumetric-level temperature uniformity using thin-film heaters while preserving optical transparency for real-time colorimetric loop-mediated isothermal amplification (LAMP) analysis on microfluidic paper-based analytical devices (µPADs). The device integrates two independently regulated indium tin oxide (ITO) heaters (8 Ω each) controlled by independent proportional–integral–derivative (PID) algorithms. Heaters were evaluated under controlled ambient environments of 4 °C (refrigerated), 23 °C (room temperature), and 50 °C (oven). Analytical tests were performed using a colorimetric LAMP assay targeting the SARS-CoV-2 orf7ab gene on µPADs preloaded with dried LAMP reagents, with time-lapse images (30 seconds interval) analyzed via Amplimetrics™ software. VitroMini maintained 65 ± 0.5 °C across 4 to 50 °C ambient conditions and achieved a limit of detection of 34 copies/reaction (4.5 copies/µL) and limit of quantification of 1000 copies/reaction (133 copies/µL), with quantification time (Tq) linearly correlated with log 10 DNA concentration. Dual-sided heating eliminated temperature bias, condensation artifacts, and ambient-dependent variability while preserving optical transparency for real-time quantitative LAMP reaction. ThermiQuant™ VitroMini bridges the gap between benchtop volumetric heaters and portable diagnostic devices, offering a compact, low-power platform for quantitative colorimetric molecular analysis on paper with potential for decentralized and field-deployable applications.
Open AccessA solid-state heater-imager for quantitative evaluation of colorimetric isothermal nucleic acid amplification on paper
Maintaining precise isothermal conditions in portable nucleic acid amplification tests (NAATs) is critical for reproducible results but remains challenging with conventional single-sided thin-film heaters, which exhibit temperature gradients and strong dependence on ambient conditions. To close this gap, we engineered ThermiQuant™ VitroMini, a dual-sided heater design that achieves volumetric-level temperature uniformity using thin-film heaters while preserving optical transparency for real-time colorimetric loop-mediated isothermal amplification (LAMP) analysis on microfluidic paper-based analytical devices (µPADs). The device integrates two independently regulated indium tin oxide (ITO) heaters (8 Ω each) controlled by independent proportional–integral–derivative (PID) algorithms. Heaters were evaluated under controlled ambient environments of 4 °C (refrigerated), 23 °C (room temperature), and 50 °C (oven). Analytical tests were performed using a colorimetric LAMP assay targeting the SARS-CoV-2 orf7ab gene on µPADs preloaded with dried LAMP reagents, with time-lapse images (30 seconds interval) analyzed via Amplimetrics™ software. VitroMini maintained 65 ± 0.5 °C across 4 to 50 °C ambient conditions and achieved a limit of detection of 34 copies/reaction (4.5 copies/µL) and limit of quantification of 1000 copies/reaction (133 copies/µL), with quantification time (Tq) linearly correlated with log 10 DNA concentration. Dual-sided heating eliminated temperature bias, condensation artifacts, and ambient-dependent variability while preserving optical transparency for real-time quantitative LAMP reaction. ThermiQuant™ VitroMini bridges the gap between benchtop volumetric heaters and portable diagnostic devices, offering a compact, low-power platform for quantitative colorimetric molecular analysis on paper with potential for decentralized and field-deployable applications.
- 1 October 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 296, 126676
A 3D printed screw-and-nut based droplet generator with facile and precise droplet size controllability
- 1 October 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 296, 126676
A 3D printed screw-and-nut based droplet generator with facile and precise droplet size controllability