Siamak Eqtesadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Siamak Eqtesadi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Magnus Johansen Anderson
The Nordic Institute of Dental Materials, NIOM Oslo Norway
2 shared publications - Abdulaziz Gul
Department of Materials Science and Technology, Division 2, Faculty of Odontology Malmö University Malmö Sweden
1 shared publication - André Konarboland1 shared publication
Annika Kozarovska
1 shared publicationAsbjørn Slagtern Fjellvåg
1 shared publication- Azadeh Motealleh
Abalonyx AS, Oslo, Norway
1 shared publication
Latest Publications
- Open Access
- 23 September 2026
- Published by Elsevier in International Dental Journal
- Vol. 76 (6)
Effect of Modified Speed Sintering Temperature and Dwell Time on the Optical and Mechanical Properties of Low-Alumina 3Y-TZP Zirconia
- 23 September 2026
- Published by Elsevier in International Dental Journal
- Vol. 76 (6)
Open AccessEffect of Modified Speed Sintering Temperature and Dwell Time on the Optical and Mechanical Properties of Low-Alumina 3Y-TZP Zirconia
- Open Access
- 13 June 2026
- Published by Wiley in Clinical Oral Implants Research
- Vol. 37 (9) , 1081-1095
Effect of Implant Design on Fracture Resistance, Mode, and Crystal Structure of One‐ and Two‐Piece Zirconia Implants With Ceramic or Titanium Abutment Screws: An In Vitro Study
Objectives: To evaluate the fracture resistance, fracture modes, and crystalline phase changes of zirconia one‐piece implants (OPI) and bone‐level (BLTPI) or tissue‐level, two‐piece implants (TLTPI), with ceramic (C) or titanium (T) abutment screws after dynamic preloading in a moist environment. Materials and Methods: Dynamic preloading under moist conditions and subsequent static load‐to‐fracture testing were performed to evaluate fracture resistance and fracture mode. Scanning electron microscopy (SEM) analysis of fracture surfaces was employed to supplement the observations of macroscopic fracture modes. Crystalline phase changes were assessed using micro‐Raman spectroscopy. Specimen preparations were performed in accordance with ISO 14801:2016. Five different ceramic (zirconia) implant designs were divided into the following groups: OPI, BLTPI (BLC, BLT), TLTPI (TLC, TLT). One‐way and two‐way ANOVA tests were used for comparisons and factor effect analysis. Results: Fracture resistance (N) and bending moment (N cm) differed significantly among the implant groups ( p < 0.001), following the order TLTPI (775.2 ± 71 N) > OPI (605.7 ± 37 N) > BLTPI (498.3 ± 93 N). Within the two‐piece implants (TPI), tissue‐level designs (TL) outperformed bone‐level designs (BL), while designs with different abutment screw materials showed no significant difference ( p = 0.982). Conclusions: Within the limitations of this in vitro study, the evaluated zirconia‐based OPI, BLTPI, and TLTPI systems demonstrate sufficient fracture resistance to support further clinical investigation. Implant‐level design (TL vs. BL) influences mechanical performance, whereas the influence of abutment screw material (ceramic vs. titanium) is less pronounced and varies according to the implant‐level design.
- 13 June 2026
- Published by Wiley in Clinical Oral Implants Research
- Vol. 37 (9) , 1081-1095
Open AccessEffect of Implant Design on Fracture Resistance, Mode, and Crystal Structure of One‐ and Two‐Piece Zirconia Implants With Ceramic or Titanium Abutment Screws: An In Vitro Study
Objectives: To evaluate the fracture resistance, fracture modes, and crystalline phase changes of zirconia one‐piece implants (OPI) and bone‐level (BLTPI) or tissue‐level, two‐piece implants (TLTPI), with ceramic (C) or titanium (T) abutment screws after dynamic preloading in a moist environment. Materials and Methods: Dynamic preloading under moist conditions and subsequent static load‐to‐fracture testing were performed to evaluate fracture resistance and fracture mode. Scanning electron microscopy (SEM) analysis of fracture surfaces was employed to supplement the observations of macroscopic fracture modes. Crystalline phase changes were assessed using micro‐Raman spectroscopy. Specimen preparations were performed in accordance with ISO 14801:2016. Five different ceramic (zirconia) implant designs were divided into the following groups: OPI, BLTPI (BLC, BLT), TLTPI (TLC, TLT). One‐way and two‐way ANOVA tests were used for comparisons and factor effect analysis. Results: Fracture resistance (N) and bending moment (N cm) differed significantly among the implant groups ( p < 0.001), following the order TLTPI (775.2 ± 71 N) > OPI (605.7 ± 37 N) > BLTPI (498.3 ± 93 N). Within the two‐piece implants (TPI), tissue‐level designs (TL) outperformed bone‐level designs (BL), while designs with different abutment screw materials showed no significant difference ( p = 0.982). Conclusions: Within the limitations of this in vitro study, the evaluated zirconia‐based OPI, BLTPI, and TLTPI systems demonstrate sufficient fracture resistance to support further clinical investigation. Implant‐level design (TL vs. BL) influences mechanical performance, whereas the influence of abutment screw material (ceramic vs. titanium) is less pronounced and varies according to the implant‐level design.
- 4 January 2021
- Published by Springer Nature in Cellulose
- Vol. 28 (3) , 1599-1616
Chitosan-Mg(OH)2 based composite membrane containing nitrogen doped GO for direct ethanol fuel cell
- 4 January 2021
- Published by Springer Nature in Cellulose
- Vol. 28 (3) , 1599-1616
Chitosan-Mg(OH)2 based composite membrane containing nitrogen doped GO for direct ethanol fuel cell