Ahmet Baran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ahmet Baran has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Erdal Karavas
Department of Radiology, Bandırma Onyedi Eylul University School of Medicine, Balıkesir, Türkiye
1 shared publication - İsmail Akgül
ERZİNCAN BİNALİ YILDIRIM ÜNİVERSİTESİ, MÜHENDİSLİK FAKÜLTESİ, BİLGİSAYAR MÜHENDİSLİĞİ BÖLÜMÜ, BİLGİSAYAR BİLİMLERİ ANABİLİM DALI
1 shared publication - Sonay Aydin
Department of Radiology, Erzincan Binali Yıldırım University, Erzincan 24100, Turkey
1 shared publication - Volkan Kaya
Erzincan Binali Yildirim Universitesi
1 shared publication
Latest Publications
- 30 January 2024
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 72 (3) , 149172
A novel artificial intelligence-based hybrid system to improve breast cancer detection using DCE-MRI
The interpretation of breast magnetic resonance imaging (MRI) in the healthcare field depends on the good knowledge and experience of radiologists. Recent developments in artificial intelligence (AI) have shown advances in the field of radiology. However, the desired levels have not been reached in the field of radiology yet. In this study, a novel model structure is proposed to characterize the diagnostic performance of AI technology for individual breast dynamic contrast material–enhanced (DCE) MRI sequences. In the proposed model structure, Inception-v3, EfficientNet-B3, and DenseNet-201 models were used as hybrids together with the Yolo-v3 algorithm to detect breast and cancer regions. In the proposed model, DCE-MRI sequences (T2, ADC, Diffusion, Non-Contrast Fat Non-Suppressed T1, Non-Contrast Fat Suppressed T1, Contrast Fat Suppressed T1, and Subtraction T1) were evaluated separately and validation was made, thus providing a unique perspective. According to the validation results, the model structure with the best performance was determined as Yolo-v3 + DenseNet-201. With this model structure, 92.41% accuracy, 0.5936 loss, 92.44% sensitivity, and 92.44% specificity rates were obtained. In addition, it was determined that the results obtained without using contrast material in the best model were 91.53% accuracy, 0.9646 loss, 92.19% sensitivity, and 92.19% specificity. Therefore, it is predicted that the need for contrast material use can be reduced with the help of this model structure.
- 30 January 2024
- Published by Polish Academy of Sciences Chancellery in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
- Vol. 72 (3) , 149172
A novel artificial intelligence-based hybrid system to improve breast cancer detection using DCE-MRI
The interpretation of breast magnetic resonance imaging (MRI) in the healthcare field depends on the good knowledge and experience of radiologists. Recent developments in artificial intelligence (AI) have shown advances in the field of radiology. However, the desired levels have not been reached in the field of radiology yet. In this study, a novel model structure is proposed to characterize the diagnostic performance of AI technology for individual breast dynamic contrast material–enhanced (DCE) MRI sequences. In the proposed model structure, Inception-v3, EfficientNet-B3, and DenseNet-201 models were used as hybrids together with the Yolo-v3 algorithm to detect breast and cancer regions. In the proposed model, DCE-MRI sequences (T2, ADC, Diffusion, Non-Contrast Fat Non-Suppressed T1, Non-Contrast Fat Suppressed T1, Contrast Fat Suppressed T1, and Subtraction T1) were evaluated separately and validation was made, thus providing a unique perspective. According to the validation results, the model structure with the best performance was determined as Yolo-v3 + DenseNet-201. With this model structure, 92.41% accuracy, 0.5936 loss, 92.44% sensitivity, and 92.44% specificity rates were obtained. In addition, it was determined that the results obtained without using contrast material in the best model were 91.53% accuracy, 0.9646 loss, 92.19% sensitivity, and 92.19% specificity. Therefore, it is predicted that the need for contrast material use can be reduced with the help of this model structure.