Martin Piroh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martin Piroh has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Andrii Diadiura
Sumy State University
1 shared publication - Damián Peti
Faculty of Manufacturing Technologies with a Seat in Presov, Technical University of Kosice, Štúrova St. 31, 080 01 Presov, Slovakia
1 shared publication - Igor Prokopovich
Odesa Polytechnic National University
1 shared publication - Irina Dyadyura
Sumy State University
1 shared publication - Michal Hatala
Technical University of Košice
1 shared publication - Miroslav Gombár
Department of Machining Technology, Faculty of Mechanical Engineering, University of West Bohemia in Pilsen, 30100 Pilsen, Czech Republic
1 shared publication
Latest Publications
- Open Access
Process Capability Assessment and Surface Quality Monitoring in Cathodic Electrodeposition of S235JRC+N Electric-Charging Station
This study presents a statistically robust quality-engineering evaluation of an industrial cathodic electrodeposition (CED) process applied to large electric-charging station components. In contrast to predominantly laboratory-scale studies, the analysis is based on 1250 thickness measurements, enabling reliable assessment of process uniformity, positional effects, and long-term stability under real production conditions. The mean coating thickness was specified at 21.84 µm with a standard deviation of 3.14 µm, fully within the specified tolerance window of 15–30 µm. One-way ANOVA revealed statistically significant but technologically small inter-station differences (F(49, 1200) = 3.49, p < 0.001), with an effect size of η2 ≈ 12.5%, indicating that most variability originates from inherent within-station common causes. Shewhart X¯–R–S control charts confirmed process stability, with all subgroup means and dispersions well inside the control limits and no evidence of special-cause variation. Distribution tests (χ2, Kolmogorov–Smirnov, Shapiro–Wilk, Anderson–Darling) detected deviations from perfect normality, primarily in the tails, attributable to the superposition of slightly heterogeneous station-specific distributions rather than fundamental non-Gaussian behaviour. Capability and performance indices were evaluated using Statistica and PalstatCAQ according to ISO 22514; the results (Cp = 0.878, Cpk = 0.808, Pp = 0.797, Ppk = 0.726) classify the process as conditionally capable, with improvement potential mainly linked to reducing positional effects and centering the mean closer to the target thickness. To complement the statistical findings, an AIAG–VDA FMEA was conducted across the entire value stream. The highest-risk failure modes—surface contamination, incorrect bath chemistry, and improper hanging—corresponded to the same mechanisms identified by SPC and ANOVA as contributors to thickness variability. Proposed corrective actions reduced RPN values by 50–62.5%, demonstrating strong potential for capability improvement. A predictive machine-learning model was implemented to estimate layer thickness and successfully reproduced the global trend while filtering process-related noise, offering a practical tool for future predictive quality control.
Open AccessProcess Capability Assessment and Surface Quality Monitoring in Cathodic Electrodeposition of S235JRC+N Electric-Charging Station
This study presents a statistically robust quality-engineering evaluation of an industrial cathodic electrodeposition (CED) process applied to large electric-charging station components. In contrast to predominantly laboratory-scale studies, the analysis is based on 1250 thickness measurements, enabling reliable assessment of process uniformity, positional effects, and long-term stability under real production conditions. The mean coating thickness was specified at 21.84 µm with a standard deviation of 3.14 µm, fully within the specified tolerance window of 15–30 µm. One-way ANOVA revealed statistically significant but technologically small inter-station differences (F(49, 1200) = 3.49, p < 0.001), with an effect size of η2 ≈ 12.5%, indicating that most variability originates from inherent within-station common causes. Shewhart X¯–R–S control charts confirmed process stability, with all subgroup means and dispersions well inside the control limits and no evidence of special-cause variation. Distribution tests (χ2, Kolmogorov–Smirnov, Shapiro–Wilk, Anderson–Darling) detected deviations from perfect normality, primarily in the tails, attributable to the superposition of slightly heterogeneous station-specific distributions rather than fundamental non-Gaussian behaviour. Capability and performance indices were evaluated using Statistica and PalstatCAQ according to ISO 22514; the results (Cp = 0.878, Cpk = 0.808, Pp = 0.797, Ppk = 0.726) classify the process as conditionally capable, with improvement potential mainly linked to reducing positional effects and centering the mean closer to the target thickness. To complement the statistical findings, an AIAG–VDA FMEA was conducted across the entire value stream. The highest-risk failure modes—surface contamination, incorrect bath chemistry, and improper hanging—corresponded to the same mechanisms identified by SPC and ANOVA as contributors to thickness variability. Proposed corrective actions reduced RPN values by 50–62.5%, demonstrating strong potential for capability improvement. A predictive machine-learning model was implemented to estimate layer thickness and successfully reproduced the global trend while filtering process-related noise, offering a practical tool for future predictive quality control.
- Open Access
- 3 November 2025
- Published by Walter de Gruyter GmbH in Management Systems in Production Engineering
- Vol. 33 (4) , 486-493
Analysis of Spatio-Temporal Eeg Structures For Application In Technology Brain-Computer Interfaces (Bci)
Brain-computer interfaces (BCIs) enable direct communication between the brain and information technologies, translating brain activity recorded intracranially into commands. Recent advances in BCIs have utilised multimodal approaches, such as electroencephalography (EEG)-based systems in combination with other biosignals, as well as deep learning to improve the efficiency and reliability of such technologies. Due to the inherent uncertainty of the data of electroencephalogram (EEG) patterns, traditional EEG diagnostic methods often face difficulties. Specifically, in multiple neurological disorders, the main motivation is to overcome the limitations of existing methods that are unable to cope with the complex and overlapping nature of EEG signals. In this paper, the use of Karhunen-Loève decomposition functions for the analysis of spatiotemporal EEG signals in a state of calm mental load in healthy persons and patients with nervous disorders is considered. Approaches in the time, frequency, and time-frequency domains are considered. The results in this study show the relationship between EEG modulation during a cognitive task involving healthy people of the control group and the pathological mental state of patients, according to the results of Karhunen-Loève decomposition in pre-selected EEG frequency ranges. The results given in this paper improve the quality and speed of recognising emotional states of patients with emotional expression disorders from the EEG signal, and also develop brain-computer interface (BCI) technologies, including for the application of artificial intelligence.
- 3 November 2025
- Published by Walter de Gruyter GmbH in Management Systems in Production Engineering
- Vol. 33 (4) , 486-493
Open AccessAnalysis of Spatio-Temporal Eeg Structures For Application In Technology Brain-Computer Interfaces (Bci)
Brain-computer interfaces (BCIs) enable direct communication between the brain and information technologies, translating brain activity recorded intracranially into commands. Recent advances in BCIs have utilised multimodal approaches, such as electroencephalography (EEG)-based systems in combination with other biosignals, as well as deep learning to improve the efficiency and reliability of such technologies. Due to the inherent uncertainty of the data of electroencephalogram (EEG) patterns, traditional EEG diagnostic methods often face difficulties. Specifically, in multiple neurological disorders, the main motivation is to overcome the limitations of existing methods that are unable to cope with the complex and overlapping nature of EEG signals. In this paper, the use of Karhunen-Loève decomposition functions for the analysis of spatiotemporal EEG signals in a state of calm mental load in healthy persons and patients with nervous disorders is considered. Approaches in the time, frequency, and time-frequency domains are considered. The results in this study show the relationship between EEG modulation during a cognitive task involving healthy people of the control group and the pathological mental state of patients, according to the results of Karhunen-Loève decomposition in pre-selected EEG frequency ranges. The results given in this paper improve the quality and speed of recognising emotional states of patients with emotional expression disorders from the EEG signal, and also develop brain-computer interface (BCI) technologies, including for the application of artificial intelligence.