Jakob Richtmann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jakob Richtmann has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Beyza Akay
Chair of Building Physics, Technical University of Munich, 80333 Munich, Germany
1 shared publication - Henrik Beermann
Fraunhofer Institute for Systems and Innovation Research ISI, 04109 Leipzig, Germany
1 shared publication - Martin Krus
Fraunhofer-Institut für Bauphysik IBP
1 shared publication - Natdanai Sinsamutpadung
Excellent Centre for Green and Sustainable Infrastructure, School of Engineering, King Mongkut’s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
1 shared publication - Ralf Kilian
Fraunhofer-Institute for Building Physics, Holzkirchen, Germany
1 shared publication - Stefan Bichlmair
Fraunhofer-Institute for Building Physics IBP, 83607 Holzkirchen, Germany
1 shared publication
Latest Publications
- Open Access
Development of a Demo Building for the Energy-Efficient Renovation of Historical Thai Wooden Houses and Computational Assessment of the Measures
This study investigated energy-efficient renovation strategies for traditional Thai wooden houses through constructing a demo building and computational assessments. The study addresses the challenges posed by climate change and increasing comfort demands, which have led to increasing use of air conditioning in these historically significant structures. A demo building, designed to replicate a traditional Thai house, was constructed, featuring two rooms: one insulated with magnesium-bonded Typha boards and the other uninsulated. The effectiveness of the insulation was evaluated through hygrothermal simulations and real-time temperature and humidity measurements. The frequently occurring problem of missing measurement data was solved by approximately determining unknown variables through iterative adjustment and comparison of simulation results with measured data. The results indicate that the Typha-insulated room maintained a stable indoor climate, with significantly lower energy consumption from air conditioning than the uninsulated room. Since the air conditioning system was insufficiently powerful in the uninsulated room, it is not possible to quantify the energy savings precisely using measurement technology. However, subsequent hygrothermal simulations enabled a comparative assessment of the energy-saving potential of various measures. Depending on insulation measures and manner of room use, savings of 75–80% could be achieved. Such computational and practical studies can contribute to the preservation of historic buildings.
Open AccessDevelopment of a Demo Building for the Energy-Efficient Renovation of Historical Thai Wooden Houses and Computational Assessment of the Measures
This study investigated energy-efficient renovation strategies for traditional Thai wooden houses through constructing a demo building and computational assessments. The study addresses the challenges posed by climate change and increasing comfort demands, which have led to increasing use of air conditioning in these historically significant structures. A demo building, designed to replicate a traditional Thai house, was constructed, featuring two rooms: one insulated with magnesium-bonded Typha boards and the other uninsulated. The effectiveness of the insulation was evaluated through hygrothermal simulations and real-time temperature and humidity measurements. The frequently occurring problem of missing measurement data was solved by approximately determining unknown variables through iterative adjustment and comparison of simulation results with measured data. The results indicate that the Typha-insulated room maintained a stable indoor climate, with significantly lower energy consumption from air conditioning than the uninsulated room. Since the air conditioning system was insufficiently powerful in the uninsulated room, it is not possible to quantify the energy savings precisely using measurement technology. However, subsequent hygrothermal simulations enabled a comparative assessment of the energy-saving potential of various measures. Depending on insulation measures and manner of room use, savings of 75–80% could be achieved. Such computational and practical studies can contribute to the preservation of historic buildings.
Klimabrunnen – Betriebssicherheit einer temperierten Wasserwand
Abstrakt: Zur Betriebssicherheit des Klimabrunnens, einer am Fraunhofer‐Institut für Bauphysik IBP entwickelten temperierten Wasserwand zur Raumluftkonditionierung, wurden verschiedene Untersuchungen und Analysen durchgeführt. In der mobilen Variante des Klimabrunnens ist ein Kupferwärmetauscher verbaut. Aufgrund der potenziellen Korrosionsgefährdung durch den sauren pH‐Wert des vom Hersteller vorgeschriebenen vollentsalzten Betriebswassers (VE‐Wasser) wurde eine qualitative Korrosionsabschätzung durchgeführt. Dazu wurde eine Massenspektrometrie mit induktiv gekoppeltem Plasma (ICP‐MS) angewandt, mit der sich Kupfer‐Ionen in Wasserproben quantifizieren lassen. Die Hypothese, dass nach einer Sättigung des Wassers durch anfallende Kupfer‐Ionen keine weitere Korrosion mehr eintritt, konnte widerlegt werden. Es wurde gezeigt, dass eine stetig fortschreitende Korrosion des Wärmetauschers zu erwarten ist. Auf der Grundlage geeigneter Normen wurden verschiedene für Kupferwerkstoffe relevante Einflussfaktoren und Korrosionsarten untersucht und bewertet sowie entsprechende mögliche Maßnahmen abgeleitet. Darüber hinaus wurde auf Basis von Anleitungen der Systemhersteller und geltender Richtlinien ein Hygiene‐ und Wartungsplan entwickelt. Dabei wurden die durchzuführenden Prüfungen und Maßnahmen sowie deren notwendige zeitliche Intervalle berücksichtigt und zusätzliche Anforderungen einbezogen.
Klimabrunnen – Betriebssicherheit einer temperierten Wasserwand
Abstrakt: Zur Betriebssicherheit des Klimabrunnens, einer am Fraunhofer‐Institut für Bauphysik IBP entwickelten temperierten Wasserwand zur Raumluftkonditionierung, wurden verschiedene Untersuchungen und Analysen durchgeführt. In der mobilen Variante des Klimabrunnens ist ein Kupferwärmetauscher verbaut. Aufgrund der potenziellen Korrosionsgefährdung durch den sauren pH‐Wert des vom Hersteller vorgeschriebenen vollentsalzten Betriebswassers (VE‐Wasser) wurde eine qualitative Korrosionsabschätzung durchgeführt. Dazu wurde eine Massenspektrometrie mit induktiv gekoppeltem Plasma (ICP‐MS) angewandt, mit der sich Kupfer‐Ionen in Wasserproben quantifizieren lassen. Die Hypothese, dass nach einer Sättigung des Wassers durch anfallende Kupfer‐Ionen keine weitere Korrosion mehr eintritt, konnte widerlegt werden. Es wurde gezeigt, dass eine stetig fortschreitende Korrosion des Wärmetauschers zu erwarten ist. Auf der Grundlage geeigneter Normen wurden verschiedene für Kupferwerkstoffe relevante Einflussfaktoren und Korrosionsarten untersucht und bewertet sowie entsprechende mögliche Maßnahmen abgeleitet. Darüber hinaus wurde auf Basis von Anleitungen der Systemhersteller und geltender Richtlinien ein Hygiene‐ und Wartungsplan entwickelt. Dabei wurden die durchzuführenden Prüfungen und Maßnahmen sowie deren notwendige zeitliche Intervalle berücksichtigt und zusätzliche Anforderungen einbezogen.