Yu He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yu He has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Dianping Tang
Fuzhou University
4 shared publications Man Xu
Fuzhou University
3 shared publicationsZhichao Yu
Fuzhou University
3 shared publicationsDi Wu
Fuzhou University
2 shared publicationsEntai Sheng
Fuzhou University
2 shared publicationsFengrui Gao
Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry
2 shared publications
Latest Publications
- 18 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (45) , 33397-33405
Valence-Engineered Regulation of Built-In Electric Field in Hollow CuS@CeO2 Heterojunction for Photoelectrochemical Immunoassay
Work function (Φ) strongly affects interfacial charge distribution and built-in electric field (BIEF) formation, fundamentally determining the photoelectric conversion efficiency of photoelectrochemical (PEC) sensors. Exploring the inherent correlation between Φ and BIEF is therefore essential to guide the rational design of PEC sensors. In this work, a PEC sensing platform was fabricated based on hollow CuS@CeO2 heterojunctions, where BIEF intensity was precisely regulated by cerium valence-state engineering. A robust BIEF was formed in high-valence CuS@CeO2(IV), which facilitates efficient photogenerated carrier separation and yields a high initial PEC signal. Following the sandwich-type immunoassay recognition of carcinoembryonic antigen (CEA), hydrogen peroxide (H2O2) generated by enzymatic reactions was used to react with high-valence CuS@CeO2(IV). After CuS@CeO2(IV) underwent a reduction reaction with H2O2, the Ce atoms in the heterojunction were reduced to form low-valence CuS@CeO2(III). The reduction in Ce valence states was accompanied by a decrease in work function difference (ΔΦ) values, which weakened the BIEF intensity. The weakened BIEF is unfavorable for the photogenerated carrier separation, thereby inducing an obvious decline in the PEC signal. Relying on this distinct signal variation, sensitive CEA detection is successfully realized by the PEC platform, which exhibits a linear detection range of 0.02−50 ng/mL and a low detection limit of 0.53 pg/mL. This study validates the efficacy of valence engineering in BIEF regulation, offering a promising strategy for the development of advanced PEC sensors for clinical diagnostic applications.
- 18 October 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (45) , 33397-33405
Valence-Engineered Regulation of Built-In Electric Field in Hollow CuS@CeO2 Heterojunction for Photoelectrochemical Immunoassay
Work function (Φ) strongly affects interfacial charge distribution and built-in electric field (BIEF) formation, fundamentally determining the photoelectric conversion efficiency of photoelectrochemical (PEC) sensors. Exploring the inherent correlation between Φ and BIEF is therefore essential to guide the rational design of PEC sensors. In this work, a PEC sensing platform was fabricated based on hollow CuS@CeO2 heterojunctions, where BIEF intensity was precisely regulated by cerium valence-state engineering. A robust BIEF was formed in high-valence CuS@CeO2(IV), which facilitates efficient photogenerated carrier separation and yields a high initial PEC signal. Following the sandwich-type immunoassay recognition of carcinoembryonic antigen (CEA), hydrogen peroxide (H2O2) generated by enzymatic reactions was used to react with high-valence CuS@CeO2(IV). After CuS@CeO2(IV) underwent a reduction reaction with H2O2, the Ce atoms in the heterojunction were reduced to form low-valence CuS@CeO2(III). The reduction in Ce valence states was accompanied by a decrease in work function difference (ΔΦ) values, which weakened the BIEF intensity. The weakened BIEF is unfavorable for the photogenerated carrier separation, thereby inducing an obvious decline in the PEC signal. Relying on this distinct signal variation, sensitive CEA detection is successfully realized by the PEC platform, which exhibits a linear detection range of 0.02−50 ng/mL and a low detection limit of 0.53 pg/mL. This study validates the efficacy of valence engineering in BIEF regulation, offering a promising strategy for the development of advanced PEC sensors for clinical diagnostic applications.
- 29 September 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (40) , 28524-28538
6:2 Chlorinated Polyfluoroalkyl Ether Sulfonate Exposure Disrupts the Gut-Liver Axis and Induces Inflammatory-Dominant Hepatotoxicity via Bile Acid-Farnesoid X Receptor Signaling
6:2 Chlorinated polyfluoroalkyl ether sulfonate (6:2 Cl-PFESA), as an alternative of perfluorooctanesulfonate (PFOS), has been widely used in the electroplating industry and frequently detected in environmental media. However, the mechanisms underlying its chronic hepatotoxicity remain incompletely understood, particularly with respect to the gut-liver axis and bile acid homeostasis. To address this knowledge gap, mice were exposed to 6:2 Cl-PFESA via drinking water for 26 weeks, resulting in estimated daily doses of approximately 0.72 and 7.78 μg/kg body weight. Toxicological evaluation revealed that prolonged 6:2 Cl-PFESA exposure induced hepatic steatosis, oxidative stress, inflammation, and liver dysfunction, accompanied by gut microbiota dysbiosis, colonic inflammation, and elevated lipopolysaccharide (LPS) levels in the colon and liver. Mechanistic analysis indicated that long-term 6:2 Cl-PFESA exposure suppressed hepatic farnesoid X receptor (FXR) signaling, thereby disrupting bile acid homeostasis, inducing gut microbiota dysbiosis, and enhancing lipopolysaccharide translocation, ultimately aggravating liver injury. Notably, pharmacological activation of FXR by obeticholic acid (OCA) partially restored bile acid homeostasis and alleviated hepatotoxicity. Collectively, these findings verify disruption of the gut-liver FXR-bile acid axis as a key mechanism contributing to 6:2 Cl-PFESA-induced liver injury.
- 29 September 2026
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 60 (40) , 28524-28538
6:2 Chlorinated Polyfluoroalkyl Ether Sulfonate Exposure Disrupts the Gut-Liver Axis and Induces Inflammatory-Dominant Hepatotoxicity via Bile Acid-Farnesoid X Receptor Signaling
6:2 Chlorinated polyfluoroalkyl ether sulfonate (6:2 Cl-PFESA), as an alternative of perfluorooctanesulfonate (PFOS), has been widely used in the electroplating industry and frequently detected in environmental media. However, the mechanisms underlying its chronic hepatotoxicity remain incompletely understood, particularly with respect to the gut-liver axis and bile acid homeostasis. To address this knowledge gap, mice were exposed to 6:2 Cl-PFESA via drinking water for 26 weeks, resulting in estimated daily doses of approximately 0.72 and 7.78 μg/kg body weight. Toxicological evaluation revealed that prolonged 6:2 Cl-PFESA exposure induced hepatic steatosis, oxidative stress, inflammation, and liver dysfunction, accompanied by gut microbiota dysbiosis, colonic inflammation, and elevated lipopolysaccharide (LPS) levels in the colon and liver. Mechanistic analysis indicated that long-term 6:2 Cl-PFESA exposure suppressed hepatic farnesoid X receptor (FXR) signaling, thereby disrupting bile acid homeostasis, inducing gut microbiota dysbiosis, and enhancing lipopolysaccharide translocation, ultimately aggravating liver injury. Notably, pharmacological activation of FXR by obeticholic acid (OCA) partially restored bile acid homeostasis and alleviated hepatotoxicity. Collectively, these findings verify disruption of the gut-liver FXR-bile acid axis as a key mechanism contributing to 6:2 Cl-PFESA-induced liver injury.
- 8 September 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (37) , 27626-27635
Colorimetric Fingerprinting of Food Antioxidants and Quality Assessment with Defect-Rich PtCu Alloy Nanozyme-Based Sensing Array
Antioxidants play critical roles in food quality, nutritional value, and health promotion, yet their rapid discrimination in complex food matrices remains challenging because of their diverse structures and redox behaviors. Herein, a defect-rich PtCu (D-PtCu) alloy nanozyme with enhanced peroxidase-like activity was developed to construct a multichannel colorimetric sensor array. By integration of three chromogenic substrates, distinct response fingerprints were generated for six representative food antioxidants. Combined with linear discriminant analysis, the sensor array achieved an accurate classification and identification of different antioxidants. Furthermore, the ascorbic acid contents determined by the proposed method agreed well with high-performance liquid chromatography (HPLC) results, and characteristic antioxidant fingerprints enabled the reliable discrimination of real food samples. This work provides a simple and rapid strategy for antioxidant profiling and food quality evaluation, demonstrating the potential of nanozyme-based sensor arrays for food analysis and nutritional assessments.
- 8 September 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (37) , 27626-27635
Colorimetric Fingerprinting of Food Antioxidants and Quality Assessment with Defect-Rich PtCu Alloy Nanozyme-Based Sensing Array
Antioxidants play critical roles in food quality, nutritional value, and health promotion, yet their rapid discrimination in complex food matrices remains challenging because of their diverse structures and redox behaviors. Herein, a defect-rich PtCu (D-PtCu) alloy nanozyme with enhanced peroxidase-like activity was developed to construct a multichannel colorimetric sensor array. By integration of three chromogenic substrates, distinct response fingerprints were generated for six representative food antioxidants. Combined with linear discriminant analysis, the sensor array achieved an accurate classification and identification of different antioxidants. Furthermore, the ascorbic acid contents determined by the proposed method agreed well with high-performance liquid chromatography (HPLC) results, and characteristic antioxidant fingerprints enabled the reliable discrimination of real food samples. This work provides a simple and rapid strategy for antioxidant profiling and food quality evaluation, demonstrating the potential of nanozyme-based sensor arrays for food analysis and nutritional assessments.
- 22 April 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (17) , 13153-13161
Target-Induced Tandem Built-In Electric Fields in the Hollow SnS 2 /ZIS@ZnS Heterojunction for the Photoelectrochemical Immunoassay
Both sluggish charge transfer and rapid recombination of photogenerated carriers lead to low photoelectric conversion efficiency, still presenting challenges for the photoelectrochemical (PEC) immunoassay. Herein, an innovative PEC sensing platform was proposed based on hollow surface immobilized SnS2–ZnIn2S4 shell-ZnS core (SnS2/ZIS@ZnS) heterojunctions with a tandem built-in electric field (BIEF). To begin with, Sn(IV)-ZIS@ZnS featuring a hollow core–shell structure was fabricated via lateral epitaxy and adsorption methods. Following the release of H2S, after carcinoembryonic antigen (CEA) was specifically recognized via a sandwich-type immune reaction, the released H2S reacted with Sn(IV)-ZIS@ZnS to form dual S-scheme heterojunction SnS2/ZIS@ZnS. Owing to the inherent differences in work function among these three heterocomponents, a tandem BIEF was established within the heterojunction. The tandem BIEF effectively facilitated charge transfer and enhanced the photoelectric conversion efficiency, ultimately enhancing the photocurrent signal. Benefiting from the pronounced variation in photocurrent, the proposed PEC sensing platform enables highly sensitive detection of CEA, exhibiting a linear detection range from 0.02 to 50 ng/mL with a detection limit as low as 3.5 pg/mL. This work provides a promising avenue to develop a high-performance PEC sensing platform based on BIEF as a signal modulation mechanism for clinical diagnostics.
- 22 April 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (17) , 13153-13161
Target-Induced Tandem Built-In Electric Fields in the Hollow SnS 2 /ZIS@ZnS Heterojunction for the Photoelectrochemical Immunoassay
Both sluggish charge transfer and rapid recombination of photogenerated carriers lead to low photoelectric conversion efficiency, still presenting challenges for the photoelectrochemical (PEC) immunoassay. Herein, an innovative PEC sensing platform was proposed based on hollow surface immobilized SnS2–ZnIn2S4 shell-ZnS core (SnS2/ZIS@ZnS) heterojunctions with a tandem built-in electric field (BIEF). To begin with, Sn(IV)-ZIS@ZnS featuring a hollow core–shell structure was fabricated via lateral epitaxy and adsorption methods. Following the release of H2S, after carcinoembryonic antigen (CEA) was specifically recognized via a sandwich-type immune reaction, the released H2S reacted with Sn(IV)-ZIS@ZnS to form dual S-scheme heterojunction SnS2/ZIS@ZnS. Owing to the inherent differences in work function among these three heterocomponents, a tandem BIEF was established within the heterojunction. The tandem BIEF effectively facilitated charge transfer and enhanced the photoelectric conversion efficiency, ultimately enhancing the photocurrent signal. Benefiting from the pronounced variation in photocurrent, the proposed PEC sensing platform enables highly sensitive detection of CEA, exhibiting a linear detection range from 0.02 to 50 ng/mL with a detection limit as low as 3.5 pg/mL. This work provides a promising avenue to develop a high-performance PEC sensing platform based on BIEF as a signal modulation mechanism for clinical diagnostics.
- Top Cited Papers
- 8 April 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (15) , 11384-11392
Partially Phosphidated Prussian Blue Analogues Derived Heterostructure Nanozyme for Colorimetric-Photothermal Dual-Mode Immunoassay
Colorimetric and photothermal sensing platforms based on nanozymes are attractive because of their simplicity, yet their sensitivity is often limited by insufficient catalytic performance. Herein, we reported a nanozyme-based strategy regulated by controlled partial phosphidation to enhance colorimetric and photothermal signal transduction. Through an etching-doping-partial phosphidation (E-D-P) strategy, polymetallic phosphide nanoparticles were in situ generated and embedded within tannic acid-etched and Cu2+-doped CoPBA nanocages, forming a phosphide-Prussian blue analogue (PBA) hybrid heterostructure. Owing to polymetallic composition and the PBA-derived structure, the resulting CuCo-P@PBA nanozyme exhibited efficient peroxidase (POD)-like catalytic activity toward the 3,3',5,5'-tetramethylbenzidine (TMB)-H2O2 system, with a high maximum reaction velocity and a low Michaelis constant, enabling effective catalytic signal amplification. Attributed to the catalytic efficiency of the CuCo-P@PBA nanozyme, a dual-mode immunosensing platform integrating colorimetric and photothermal readouts was constructed. The colorimetric mode exhibited a linear response over 0.005-50 ng mL-1 with a limit of detection (LOD) of 3.4 pg mL-1, while the photothermal mode provided a linear range of 0.01-50 ng mL-1 with an LOD of 4.0 pg mL-1. The colorimetric response at 652 nm and photothermal signal under 808 nm irradiation provided two correlated signal outputs. The platform enables sensitive determination of human epidermal growth factor receptor 2 (HER2) with a wide linear range and good agreement with a commercial enzyme-linked immunosorbent assay (ELISA) in clinical serum samples, highlighting its potential for reliable bioanalytical sensing.
- 8 April 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 98 (15) , 11384-11392
Top Cited PapersPartially Phosphidated Prussian Blue Analogues Derived Heterostructure Nanozyme for Colorimetric-Photothermal Dual-Mode Immunoassay
Colorimetric and photothermal sensing platforms based on nanozymes are attractive because of their simplicity, yet their sensitivity is often limited by insufficient catalytic performance. Herein, we reported a nanozyme-based strategy regulated by controlled partial phosphidation to enhance colorimetric and photothermal signal transduction. Through an etching-doping-partial phosphidation (E-D-P) strategy, polymetallic phosphide nanoparticles were in situ generated and embedded within tannic acid-etched and Cu2+-doped CoPBA nanocages, forming a phosphide-Prussian blue analogue (PBA) hybrid heterostructure. Owing to polymetallic composition and the PBA-derived structure, the resulting CuCo-P@PBA nanozyme exhibited efficient peroxidase (POD)-like catalytic activity toward the 3,3',5,5'-tetramethylbenzidine (TMB)-H2O2 system, with a high maximum reaction velocity and a low Michaelis constant, enabling effective catalytic signal amplification. Attributed to the catalytic efficiency of the CuCo-P@PBA nanozyme, a dual-mode immunosensing platform integrating colorimetric and photothermal readouts was constructed. The colorimetric mode exhibited a linear response over 0.005-50 ng mL-1 with a limit of detection (LOD) of 3.4 pg mL-1, while the photothermal mode provided a linear range of 0.01-50 ng mL-1 with an LOD of 4.0 pg mL-1. The colorimetric response at 652 nm and photothermal signal under 808 nm irradiation provided two correlated signal outputs. The platform enables sensitive determination of human epidermal growth factor receptor 2 (HER2) with a wide linear range and good agreement with a commercial enzyme-linked immunosorbent assay (ELISA) in clinical serum samples, highlighting its potential for reliable bioanalytical sensing.
- 19 November 2025
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 73 (48) , 30714-30725
Chronic Triclosan Exposure Promotes Metabolic Dysregulation and Colitis in Mice: A Dose–Dependent Relationship
Triclosan (TCS), a widely used antimicrobial agent in personal care products, typically undergoes phase II metabolism for detoxification. Notably, its phase II metabolites can be reconverted into the parent TCS by microbial activity, revealing their potential toxicological risks. Hence, this study investigated the tissue distribution and metabolic effects in mice following 160 day exposure to TCS at 0.5 or 5 mg/kg/day. The results showed that TCS mainly accumulated in the colon, where it disrupted energy metabolism, enhanced purine metabolism, and elevated reactive oxygen species levels. Lipidomic analyses revealed dose-dependent perturbations: the low dose promoted sphingomyelin synthesis, while the high dose stimulated glycerophospholipid synthesis. Mechanistic evidence from molecular docking and Western blot suggested that these effects might be linked to TCS-induced alterations in mitofusin 2 activity. Overall, these findings provide new insights into the dose-specific mechanisms of TCS-induced intestinal toxicity.
- 19 November 2025
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 73 (48) , 30714-30725
Chronic Triclosan Exposure Promotes Metabolic Dysregulation and Colitis in Mice: A Dose–Dependent Relationship
Triclosan (TCS), a widely used antimicrobial agent in personal care products, typically undergoes phase II metabolism for detoxification. Notably, its phase II metabolites can be reconverted into the parent TCS by microbial activity, revealing their potential toxicological risks. Hence, this study investigated the tissue distribution and metabolic effects in mice following 160 day exposure to TCS at 0.5 or 5 mg/kg/day. The results showed that TCS mainly accumulated in the colon, where it disrupted energy metabolism, enhanced purine metabolism, and elevated reactive oxygen species levels. Lipidomic analyses revealed dose-dependent perturbations: the low dose promoted sphingomyelin synthesis, while the high dose stimulated glycerophospholipid synthesis. Mechanistic evidence from molecular docking and Western blot suggested that these effects might be linked to TCS-induced alterations in mitofusin 2 activity. Overall, these findings provide new insights into the dose-specific mechanisms of TCS-induced intestinal toxicity.