Silas B. Schack
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Silas B. Schack has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Kim Lefmann
Nanoscience Center, Niels Bohr Institute, University of Copenhagen, Copenhagen, Denmark
4 shared publications - Emma Y. Lenander
Niels Bohr Institute, University of Copenhagen, DK-2100 Copenhagen Ø, Denmark
3 shared publications - Kristine Marie Løfgren Krighaar
Nanoscience Center Niels Bohr Institute University of Copenhagen 2100 Copenhagen Denmark
3 shared publications - Henrik Moodysson Rønnow
École Polytechnique Fédérale de Lausanne (EPFL)
2 shared publications Emma Y. Lenander
Niels Bohr Institute University of Copenhagen DK-2100 Copenhagen Ø Denmark
1 shared publication- Gregory S. Tucker
Ames Laboratory, Ames, Iowa 50011, USA
1 shared publication
Latest Publications
- Open Access
- 6 November 2026
- Published by MDPI AG in Quantum Beam Science
- Vol. 10 (4) , 25
Characterization of the BIFROST Spectrometer Through Virtual Experiments
Using the Monte Carlo ray tracing package McStas, we illustrate the possibilities of creating virtual experiments of the neutron spectrometer BIFROST, before its commissioning at the European Spallation Source (ESS). With this model, we are able to benchmark BIFROST with respect to expected intensity, Q-and energy resolution. The simulations reproduce the expected resolution behaviour and quantify effects that are difficult to capture analytically, including a wavelength-dependent edge enhancement arising from a combination of the long-pulsed source and the pulse-shaping chopper. Furthermore, we present an antiferromagnetic (AF) spin wave simulation, which we use to create realistic datasets at different instrument operation settings. Our virtual experiments focus on realistic dispersive dynamics and illustrate how the virtual experiment approach reveals resolution effects that are not easily calculable via analytical models. This demonstrates the crucial role of numerical simulations in understanding the behaviour of neutron instruments during the design and construction phases.
- 6 November 2026
- Published by MDPI AG in Quantum Beam Science
- Vol. 10 (4) , 25
Open AccessCharacterization of the BIFROST Spectrometer Through Virtual Experiments
Using the Monte Carlo ray tracing package McStas, we illustrate the possibilities of creating virtual experiments of the neutron spectrometer BIFROST, before its commissioning at the European Spallation Source (ESS). With this model, we are able to benchmark BIFROST with respect to expected intensity, Q-and energy resolution. The simulations reproduce the expected resolution behaviour and quantify effects that are difficult to capture analytically, including a wavelength-dependent edge enhancement arising from a combination of the long-pulsed source and the pulse-shaping chopper. Furthermore, we present an antiferromagnetic (AF) spin wave simulation, which we use to create realistic datasets at different instrument operation settings. Our virtual experiments focus on realistic dispersive dynamics and illustrate how the virtual experiment approach reveals resolution effects that are not easily calculable via analytical models. This demonstrates the crucial role of numerical simulations in understanding the behaviour of neutron instruments during the design and construction phases.
- Open Access
- 30 April 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (3) , 816-826
Accurate simulations of magnetic excitations in the neutron simulation package McStas
An algorithm for the accurate simulation of neutron scattering from magnetic excitations has been developed and implemented as new component for the neutron ray-tracing software McStas . The component SpinWave_BCO simulates inelastic neutron scattering from ferro-, antiferro- and altermagnetic excitations in a body-centred orthorhombic crystal structure, where the dispersion relation and scattered neutron intensities are derived using linear spin wave theory. Data from a simulated triple-axis spectrometer with an extremely high resolution have been verified by direct comparison with theory and by comparison with data simulated using the package SpinW . The component serves as a proof of concept for the implementation of a more general linear spin wave component in McStas .
- 30 April 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (3) , 816-826
Open AccessAccurate simulations of magnetic excitations in the neutron simulation package McStas
An algorithm for the accurate simulation of neutron scattering from magnetic excitations has been developed and implemented as new component for the neutron ray-tracing software McStas . The component SpinWave_BCO simulates inelastic neutron scattering from ferro-, antiferro- and altermagnetic excitations in a body-centred orthorhombic crystal structure, where the dispersion relation and scattered neutron intensities are derived using linear spin wave theory. Data from a simulated triple-axis spectrometer with an extremely high resolution have been verified by direct comparison with theory and by comparison with data simulated using the package SpinW . The component serves as a proof of concept for the implementation of a more general linear spin wave component in McStas .
- Open Access
- 22 April 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (3) , 783-798
Approximate resolution convolution function for fitting a dispersion gap measured on a triple-axis spectrometer
We present an analytical convoluted gap function for fitting dispersion gaps measured on a triple-axis spectrometer (TAS). At the gap, the instrumental resolution skews the signal, producing a high-energy tail that complicates fitting. Our function assumes an instrumental Q resolution with two equal wide directions and one narrow direction (typical of focused TAS instruments) and a parabolic dispersion at the gap, which is exact for quadratic and accurate for linear dispersions if the resolution is moderate. We demonstrate that our function outperforms previous methods of fitting a gap by giving a better fit and more accurate gap determination. Here, the antiferromagnetically gapped material MnF 2 is simulated in a double-focusing TAS instrument. We also tested our function on experimental data on MnF 2 from a TAS-like instrument, where we reproduced the gap size from previous accurate measurements determined experimentally. The function is simple to implement and converges reliably, and we recommend its use for future gap fitting on TAS data.
- 22 April 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (3) , 783-798
Open AccessApproximate resolution convolution function for fitting a dispersion gap measured on a triple-axis spectrometer
We present an analytical convoluted gap function for fitting dispersion gaps measured on a triple-axis spectrometer (TAS). At the gap, the instrumental resolution skews the signal, producing a high-energy tail that complicates fitting. Our function assumes an instrumental Q resolution with two equal wide directions and one narrow direction (typical of focused TAS instruments) and a parabolic dispersion at the gap, which is exact for quadratic and accurate for linear dispersions if the resolution is moderate. We demonstrate that our function outperforms previous methods of fitting a gap by giving a better fit and more accurate gap determination. Here, the antiferromagnetically gapped material MnF 2 is simulated in a double-focusing TAS instrument. We also tested our function on experimental data on MnF 2 from a TAS-like instrument, where we reproduced the gap size from previous accurate measurements determined experimentally. The function is simple to implement and converges reliably, and we recommend its use for future gap fitting on TAS data.
- Open Access
Accurate simulations of magnetic excitations in the neutron simulation package McStas
A new component for the accurate simulation of neutron scattering from magnetic excitations has been developed for the neutron ray-tracing software McStas. The component SpinWave_BCO simulates inelastic neutron scattering from ferro-, antiferro-, and altermagnetic excitations in a body-centered orthorhombic crystal structure, where the dispersion relation and scattered neutron intensities are derived using linear spin wave theory. Data from a simulated Triple-Axis Spectrometer with an extremely high resolution have been verified by direct comparison with theory and by comparison to data simulated using the package SpinW. The component serves as a proof-of-concept for the implementation of a more general linear spin wave component in McStas.
Open AccessAccurate simulations of magnetic excitations in the neutron simulation package McStas
A new component for the accurate simulation of neutron scattering from magnetic excitations has been developed for the neutron ray-tracing software McStas. The component SpinWave_BCO simulates inelastic neutron scattering from ferro-, antiferro-, and altermagnetic excitations in a body-centered orthorhombic crystal structure, where the dispersion relation and scattered neutron intensities are derived using linear spin wave theory. Data from a simulated Triple-Axis Spectrometer with an extremely high resolution have been verified by direct comparison with theory and by comparison to data simulated using the package SpinW. The component serves as a proof-of-concept for the implementation of a more general linear spin wave component in McStas.
- Open Access
Approximate resolution convolution function for fitting a dispersion gap measured on a triple-axis spectrometer
We present an analytic convoluted-gap function, eq. 11 in the manuscript, for fitting dispersion gaps measured on triple-axis spectrometers (TAS). At the gap, the instrumental resolution skews the signal, producing a high-energy tail that complicates fitting. Our function assumes an instrumental $Q$-resolution with two equal wide and one narrow direction (typical of focused TAS instruments), and a parabolic dispersion at the gap, which is exact for quadratic and accurate for linear dispersions if the resolution is moderate. We demonstrate, that our function outperforms previous methods of fitting a gap, by giving a better fit and more accurate gap determination, seen in figure 4. Here, the anti-ferromagnetically gapped material; MnF$_2$ is simulated in a double-focusing TAS instrument. We also tested our function on experimental data on MnF$_2$ from a TAS-like instrument, where we reproduce the gap size from previous accurate experimentally determined measurements. The function is simple to implement, converges reliably, and we recommend its use for future gap fitting on TAS data.Open AccessApproximate resolution convolution function for fitting a dispersion gap measured on a triple-axis spectrometer
We present an analytic convoluted-gap function, eq. 11 in the manuscript, for fitting dispersion gaps measured on triple-axis spectrometers (TAS). At the gap, the instrumental resolution skews the signal, producing a high-energy tail that complicates fitting. Our function assumes an instrumental $Q$-resolution with two equal wide and one narrow direction (typical of focused TAS instruments), and a parabolic dispersion at the gap, which is exact for quadratic and accurate for linear dispersions if the resolution is moderate. We demonstrate, that our function outperforms previous methods of fitting a gap, by giving a better fit and more accurate gap determination, seen in figure 4. Here, the anti-ferromagnetically gapped material; MnF$_2$ is simulated in a double-focusing TAS instrument. We also tested our function on experimental data on MnF$_2$ from a TAS-like instrument, where we reproduce the gap size from previous accurate experimentally determined measurements. The function is simple to implement, converges reliably, and we recommend its use for future gap fitting on TAS data.